-
Notifications
You must be signed in to change notification settings - Fork 57
/
iot-telemetry-send.html
144 lines (122 loc) · 4.91 KB
/
iot-telemetry-send.html
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
<!--
Copyright 2020 Google Inc.
Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS,
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
See the License for the specific language governing permissions and
limitations under the License.
-->
<script type="text/html" data-template-name="google-cloud-iot telemetry-send">
<!--Name-->
<div class="form-row">
<label for="node-input-name"><i class="fa fa-tag"></i> Name</label>
<input type="text" id="node-input-name">
</div>
<!--Project ID-->
<div class="form-row">
<label for="node-input-projectId"><i class="fa fa-cloud"></i> Project ID</label>
<input type="text" id="node-input-projectId">
</div>
<!--Region-->
<div class="form-row">
<label for="node-input-region"><i class="fa fa-globe"></i> Region</label>
<input type="text" id="node-input-region">
</div>
<!--Registry ID-->
<div class="form-row">
<label for="node-input-registryId"><i class="fa fa-book"></i> Registry ID</label>
<input type="text" id="node-input-registryId">
</div>
<!--Device ID-->
<div class="form-row">
<label for="node-input-deviceId"><i class="fa fa-microchip"></i> Device ID</label>
<input type="text" id="node-input-deviceId">
</div>
<!--SubFolder-->
<div class="form-row">
<label for="node-input-subfolder"><i class="fa fa-folder"></i> SubFolder</label>
<input type="text" id="node-input-subfolder">
</div>
<!--Private Key-->
<div class="form-row">
<label for="node-input-privateKey"><i class="fa fa-key"></i> Private Key</label>
<input type="text" id="node-input-privateKey">
</div>
<!--Transport-->
<div class="form-row">
<label for="node-input-transport"><i class="fa fa-gear"></i> Transport</label>
<select type="text" id="node-input-transport">
<option value="MQTT">MQTT</option>
<option value="HTTP">HTTP</option>
</select>
</div>
</script>
<script type="text/html" data-help-name="google-cloud-iot telemetry-send">
<p>Send a telemetry message to the cloud.</p>
<h3>Inputs</h3>
<dl class="message-properties">
<dt>msg.gcp.projectId
<span class="property-type">string</span>
</dt>
<dd>The project id hosting the registry of devices.</dd>
<dt>msg.gcp.region
<span class="property-type">string</span>
</dt>
<dd>The region in which the registry is defined..</dd>
<dt>msg.gcp.registryId
<span class="property-type">string</span>
</dt>
<dd>The identity of the registry.</dd>
<dt>msg.gcp.deviceId
<span class="property-type">string</span>
</dt>
<dd>The identity of the device.</dd>
<dt>msg.gcp.subFolder
<span class="property-type">string</span>
</dt>
<dd>The topic sub folder.</dd>
</dl>
<h3>Details</h3>
<p>
The GCP IoT Core allows one to send messages from the device to the Cloud. The transmission can occur over either TCP/IP or MQTT.
In order to send telemetry to the cloud, we need to identify that device. The properties to identify it are the combination of:
<ul>
<li><code>project id</code> - The project hosting the registry.</li>
<li><code>region</code> - The region in which the registry is defined.</li>
<li><code>registry id</code> - The identity of the registry.</li>
<li><code>device id</code> - The identity of the device.</li>
</ul>
</p>
<p>
The device must also authenticate itself and needs to be supplied a private key corresponding to the public key associated with the device in the registry.
The <code>msg.payload</code> field is the content that is sent as telemetry.
</p>
</script>
<script type="text/javascript">
RED.nodes.registerType("google-cloud-iot telemetry-send", {
"category": "GCP",
"defaults": {
"projectId": { "required": true },
"region": { "required": true },
"registryId": { "required": true },
"deviceId": { "required": true },
"subfolder": { "required": false },
"name": { "value": "", "required": false },
"privateKey": { "type": "google-cloud-private-key", "required": true },
"transport": { "value": "MQTT", "required": false }
},
"inputs": 1,
"outputs": 1,
"icon": "iot.png",
"align": "left",
"color": "#3FADB5",
"label": function () {
return this.name || this.topic || "iot telemetry-send";
},
"paletteLabel": "iot telemetry send"
});
</script>