missing variable in ICs #19

Open
jdha opened this issue Apr 17, 2023 · 4 comments
Open

missing variable in ICs #19

jdha opened this issue Apr 17, 2023 · 4 comments
Assignees
Labels
bug Something isn't working

Comments

@jdha
Copy link
Contributor

jdha commented Apr 17, 2023

Having tried to run the original CO AMM7 set up - I've found the there is a missing variable (mask) in the ICs. Not sure how others have managed to run this config in the past. I'll add this into the INPUTS and test.

@jdha jdha added the bug Something isn't working label Apr 17, 2023
@jdha jdha self-assigned this Apr 17, 2023
@rdPatmore
Copy link

I came across this missing variable. The simulation runs if you remove the vertical interpolation.

@jdha
Copy link
Contributor Author

jdha commented Apr 17, 2023

thanks @rdPatmore, I realise that this is the case. I was just raising an issue to rectify the problem as we're likely to switch between MES and Siddorn and Furner vertical coordinates. I haven't checked but I have a feeling if you're running with MES then you need to run with vertical interpolation as the ICs are on the old vertical grid.

@jdha
Copy link
Contributor Author

jdha commented Apr 17, 2023

FYI I introduced the vertical interpolation code into dtatsd.F90 in order not to have to create new ICs every time we changed the vertical grid.

@jdha
Copy link
Contributor Author

jdha commented May 3, 2023

ICs updated to include mask and gdept