forked from LPRS2/lab5
-
Notifications
You must be signed in to change notification settings - Fork 0
/
psf2Edward.log
84 lines (73 loc) · 4.16 KB
/
psf2Edward.log
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
Checking platform configuration ...
IPNAME: lmb_v10, INSTANCE: microblaze_0_ilmb - 1 master(s) : 1 slave(s)
IPNAME: lmb_v10, INSTANCE: microblaze_0_dlmb - 1 master(s) : 1 slave(s)
IPNAME: axi_interconnect, INSTANCE: axi4lite_0 - 1 master(s) : 5 slave(s)
WARNING:EDK:3977 - AXI4 protocol type BUSIF: S_AXI of IPINSTANCE:
vga_periph_mem_0 connected with AXI4LITE type BUSIF: M_AXI_DP of IPINSTANCE:
microblaze_0.
Checking port drivers...
WARNING:EDK:4180 - PORT: Interrupt_address_in, CONNECTOR: Interrupt_address_in -
No driver found. Port will be driven to GND -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\axi_intc_v1_04_a\dat
a\axi_intc_v2_1_0.mpd line 131
WARNING:EDK:4181 - PORT: Processor_ack_out, CONNECTOR: Processor_ack_out -
floating connection -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\axi_intc_v1_04_a\dat
a\axi_intc_v2_1_0.mpd line 132
Performing Clock DRCs...
Performing Reset DRCs...
Overriding system level properties...
INFO:EDK:4130 - IPNAME: lmb_bram_if_cntlr, INSTANCE:microblaze_0_i_bram_ctrl -
tcl is overriding PARAMETER C_MASK value to 0x40000000 -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\lmb_bram_if_cntlr_v3
_10_c\data\lmb_bram_if_cntlr_v2_1_0.mpd line 92
INFO:EDK:4130 - IPNAME: lmb_bram_if_cntlr, INSTANCE:microblaze_0_d_bram_ctrl -
tcl is overriding PARAMETER C_MASK value to 0x40000000 -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\lmb_bram_if_cntlr_v3
_10_c\data\lmb_bram_if_cntlr_v2_1_0.mpd line 92
INFO:EDK:4130 - IPNAME: microblaze, INSTANCE:microblaze_0 - tcl is overriding
PARAMETER C_D_AXI value to 1 -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\microblaze_v8_50_b\d
ata\microblaze_v2_1_0.mpd line 232
INFO:EDK:4130 - IPNAME: microblaze, INSTANCE:microblaze_0 - tcl is overriding
PARAMETER C_ADDR_TAG_BITS value to 0 -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\microblaze_v8_50_b\d
ata\microblaze_v2_1_0.mpd line 337
INFO:EDK:4130 - IPNAME: microblaze, INSTANCE:microblaze_0 - tcl is overriding
PARAMETER C_DCACHE_ADDR_TAG value to 0 -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\microblaze_v8_50_b\d
ata\microblaze_v2_1_0.mpd line 367
INFO:EDK:4130 - IPNAME: microblaze, INSTANCE:microblaze_0 - tcl is overriding
PARAMETER C_USE_EXT_BRK value to 1 -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\microblaze_v8_50_b\d
ata\microblaze_v2_1_0.mpd line 402
INFO:EDK:4130 - IPNAME: microblaze, INSTANCE:microblaze_0 - tcl is overriding
PARAMETER C_USE_EXT_NM_BRK value to 1 -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\microblaze_v8_50_b\d
ata\microblaze_v2_1_0.mpd line 403
INFO: Setting C_RANGE_CHECK = ON for axi_interconnect axi4lite_0.
INFO:EDK:4130 - IPNAME: axi_interconnect, INSTANCE:axi4lite_0 - tcl is
overriding PARAMETER C_RANGE_CHECK value to 1 -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\axi_interconnect_v1_
06_a\data\axi_interconnect_v2_1_0.mpd line 149
INFO:EDK:4130 - IPNAME: axi_intc, INSTANCE:axi_intc_0 - tcl is overriding
PARAMETER C_KIND_OF_INTR value to 0b11111111111111111111111111111111 -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\axi_intc_v1_04_a\dat
a\axi_intc_v2_1_0.mpd line 87
INFO:EDK:4130 - IPNAME: axi_intc, INSTANCE:axi_intc_0 - tcl is overriding
PARAMETER C_KIND_OF_EDGE value to 0b11111111111111111111111111111111 -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\axi_intc_v1_04_a\dat
a\axi_intc_v2_1_0.mpd line 88
INFO:EDK:4130 - IPNAME: axi_intc, INSTANCE:axi_intc_0 - tcl is overriding
PARAMETER C_KIND_OF_LVL value to 0b11111111111111111111111111111111 -
C:\Xilinx\14.6\ISE_DS\EDK\hw\XilinxProcessorIPLib\pcores\axi_intc_v1_04_a\dat
a\axi_intc_v2_1_0.mpd line 89
Running system level update procedures...
Running UPDATE Tcl procedures for OPTION SYSLEVEL_UPDATE_PROC...
Running system level DRCs...
Performing System level DRCs on properties...
Running DRC Tcl procedures for OPTION SYSLEVEL_DRC_PROC...
INTC_WARNING:: IRQ is not connected to Processor.
INTC INFO:: Processor_clk not connected.. IRQ to Microblaze is generated on AXI
clock.
Conversion to XML complete.