Describe the bug
When implementing the various ways to implement ObjectManager (either ObjectManager_Adaptor or addObjectManager() member function) on a System Bus connection the object isn't introspectable in d-feet. If I do the same on a session bus it works as expected.
To Reproduce
This example is taken from #50 and adapted slightly but it also happens with my ObjectManager_Adaptor code.
#include "sdbus-c++/IConnection.h"
#include <sdbus-c++/sdbus-c++.h>
int main(int argc, char *argv[])
{
// Create D-Bus connection to the system bus and requests name on it.
const char* serviceName = "org.example.service";
// auto connection = sdbus::createSystemBusConnection(serviceName);
auto connection = sdbus::createSessionBusConnection(serviceName);
// Create D-Bus object.
const char* objectPath = "/org/example/service";
auto serviceObject = sdbus::createObject(*connection, objectPath);
// Register D-Bus property on the object, and export the object.
const char* interfaceName = "org.example.service";
serviceObject->registerProperty("Name").onInterface(interfaceName).withGetter([](){ return "hello"; }).withSetter([](const uint32_t& value){ });
serviceObject->addObjectManager();
serviceObject->finishRegistration();
// Start the service
connection->enterEventLoop();
}
Uncomment the different connection types to test.
Expected behavior
I expect the ObjectManager to behave the same on both system and session bus unless my understanding is incorrect.
Real (buggy) behavior
System bus object isn't introspectable.
Additional context
Ubuntu 20.04 - 5.15.0-88-generic.
Systemd version 245.
The text was updated successfully, but these errors were encountered:
Describe the bug
When implementing the various ways to implement ObjectManager (either ObjectManager_Adaptor or addObjectManager() member function) on a System Bus connection the object isn't introspectable in d-feet. If I do the same on a session bus it works as expected.
To Reproduce
This example is taken from #50 and adapted slightly but it also happens with my ObjectManager_Adaptor code.
Uncomment the different connection types to test.
Expected behavior
I expect the ObjectManager to behave the same on both system and session bus unless my understanding is incorrect.
Real (buggy) behavior
System bus object isn't introspectable.
Additional context
The text was updated successfully, but these errors were encountered: