diff --git a/.vscode/settings.json b/.vscode/settings.json index f8137d519..1893589ab 100644 --- a/.vscode/settings.json +++ b/.vscode/settings.json @@ -93,9 +93,9 @@ "makefile" ], "typescript.preferences.preferTypeOnlyAutoImports": true, + "sonarlint.pathToCompileCommands": "${workspaceFolder}/compile_commands.json", "sonarlint.connectedMode.project": { "connectionId": "emsesp", "projectKey": "emsesp_EMS-ESP32" - }, - "sonarlint.pathToCompileCommands": "${workspaceFolder}/compile_commands.json" + } } \ No newline at end of file diff --git a/dump_entities.csv b/dump_entities.csv index 199a7348c..7fc21cbe6 100644 --- a/dump_entities.csv +++ b/dump_entities.csv @@ -1,207 +1,207 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/max),uom,writeable,discovery entityid v3.4,discovery entityid,modbus unit identifier,modbus block,modbus scale factor,modbus offset,modbus count -CS6800i/WLW176i,boiler,8,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -CS6800i/WLW176i,boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -CS6800i/WLW176i,boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -CS6800i/WLW176i,boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -CS6800i/WLW176i,boiler,8,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -CS6800i/WLW176i,boiler,8,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -CS6800i/WLW176i,boiler,8,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -CS6800i/WLW176i,boiler,8,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -CS6800i/WLW176i,boiler,8,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -CS6800i/WLW176i,boiler,8,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -CS6800i/WLW176i,boiler,8,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -CS6800i/WLW176i,boiler,8,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -CS6800i/WLW176i,boiler,8,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -CS6800i/WLW176i,boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -CS6800i/WLW176i,boiler,8,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -CS6800i/WLW176i,boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -CS6800i/WLW176i,boiler,8,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -CS6800i/WLW176i,boiler,8,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -CS6800i/WLW176i,boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -CS6800i/WLW176i,boiler,8,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -CS6800i/WLW176i,boiler,8,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -CS6800i/WLW176i,boiler,8,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -CS6800i/WLW176i,boiler,8,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -CS6800i/WLW176i,boiler,8,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -CS6800i/WLW176i,boiler,8,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -CS6800i/WLW176i,boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -CS6800i/WLW176i,boiler,8,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -CS6800i/WLW176i,boiler,8,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -CS6800i/WLW176i,boiler,8,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -CS6800i/WLW176i,boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -CS6800i/WLW176i,boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -CS6800i/WLW176i,boiler,8,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -CS6800i/WLW176i,boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -CS6800i/WLW176i,boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -CS6800i/WLW176i,boiler,8,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -CS6800i/WLW176i,boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -CS6800i/WLW176i,boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -CS6800i/WLW176i,boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -CS6800i/WLW176i,boiler,8,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -CS6800i/WLW176i,boiler,8,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2 -CS6800i/WLW176i,boiler,8,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,82,2 -CS6800i/WLW176i,boiler,8,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,264,2 -CS6800i/WLW176i,boiler,8,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,84,2 -CS6800i/WLW176i,boiler,8,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,86,2 -CS6800i/WLW176i,boiler,8,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,88,2 -CS6800i/WLW176i,boiler,8,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,90,2 -CS6800i/WLW176i,boiler,8,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,266,2 -CS6800i/WLW176i,boiler,8,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2 -CS6800i/WLW176i,boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,92,2 -CS6800i/WLW176i,boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,94,2 -CS6800i/WLW176i,boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,96,2 -CS6800i/WLW176i,boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,98,2 -CS6800i/WLW176i,boiler,8,uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2 -CS6800i/WLW176i,boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,100,2 -CS6800i/WLW176i,boiler,8,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,102,2 -CS6800i/WLW176i,boiler,8,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,104,2 -CS6800i/WLW176i,boiler,8,coolingstarts,cooling control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,106,2 -CS6800i/WLW176i,boiler,8,starts2,control starts2,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_control_starts2,sensor.boiler_dhw_starts2,5,9,1,6,2 -CS6800i/WLW176i,boiler,8,poolstarts,pool control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,108,2 -CS6800i/WLW176i,boiler,8,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,110,2 -CS6800i/WLW176i,boiler,8,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,112,2 -CS6800i/WLW176i,boiler,8,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,114,2 -CS6800i/WLW176i,boiler,8,nrgconscomp,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2 -CS6800i/WLW176i,boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,116,2 -CS6800i/WLW176i,boiler,8,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,118,2 -CS6800i/WLW176i,boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,120,2 -CS6800i/WLW176i,boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,122,2 -CS6800i/WLW176i,boiler,8,auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2 -CS6800i/WLW176i,boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,124,2 -CS6800i/WLW176i,boiler,8,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,126,2 -CS6800i/WLW176i,boiler,8,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,128,2 -CS6800i/WLW176i,boiler,8,nrgsupp,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2 -CS6800i/WLW176i,boiler,8,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,130,2 -CS6800i/WLW176i,boiler,8,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,132,2 -CS6800i/WLW176i,boiler,8,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,134,1 -CS6800i/WLW176i,boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,135,1 -CS6800i/WLW176i,boiler,8,hpsetdiffpress,set differental pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress,5,0,50,136,1 -CS6800i/WLW176i,boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,137,1 -CS6800i/WLW176i,boiler,8,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,138,1 -CS6800i/WLW176i,boiler,8,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,139,1 -CS6800i/WLW176i,boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,140,1 -CS6800i/WLW176i,boiler,8,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,141,1 -CS6800i/WLW176i,boiler,8,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,142,1 -CS6800i/WLW176i,boiler,8,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,143,1 -CS6800i/WLW176i,boiler,8,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,144,1 -CS6800i/WLW176i,boiler,8,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,145,1 -CS6800i/WLW176i,boiler,8,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,146,1 -CS6800i/WLW176i,boiler,8,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,147,1 -CS6800i/WLW176i,boiler,8,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,148,1 -CS6800i/WLW176i,boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,149,1 -CS6800i/WLW176i,boiler,8,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,150,1 -CS6800i/WLW176i,boiler,8,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,151,1 -CS6800i/WLW176i,boiler,8,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,152,1 -CS6800i/WLW176i,boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,153,1 -CS6800i/WLW176i,boiler,8,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,154,1 -CS6800i/WLW176i,boiler,8,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,155,1 -CS6800i/WLW176i,boiler,8,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,156,1 -CS6800i/WLW176i,boiler,8,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,157,1 -CS6800i/WLW176i,boiler,8,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,158,1 -CS6800i/WLW176i,boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,159,1 -CS6800i/WLW176i,boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,160,1 -CS6800i/WLW176i,boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,161,1 -CS6800i/WLW176i,boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,162,8 -CS6800i/WLW176i,boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,170,1 -CS6800i/WLW176i,boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,171,8 -CS6800i/WLW176i,boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,179,1 -CS6800i/WLW176i,boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,180,8 -CS6800i/WLW176i,boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,188,1 -CS6800i/WLW176i,boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,189,8 -CS6800i/WLW176i,boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,197,1 -CS6800i/WLW176i,boiler,8,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,198,1 -CS6800i/WLW176i,boiler,8,maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1 -CS6800i/WLW176i,boiler,8,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost,5,0,1,199,1 -CS6800i/WLW176i,boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,200,1 -CS6800i/WLW176i,boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,201,1 -CS6800i/WLW176i,boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,202,1 -CS6800i/WLW176i,boiler,8,auxheaterstatus,aux heater status,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,203,1 -CS6800i/WLW176i,boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,204,1 -CS6800i/WLW176i,boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,205,1 -CS6800i/WLW176i,boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,206,1 -CS6800i/WLW176i,boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,207,1 -CS6800i/WLW176i,boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,208,1 -CS6800i/WLW176i,boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,209,1 -CS6800i/WLW176i,boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,210,1 -CS6800i/WLW176i,boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,211,1 -CS6800i/WLW176i,boiler,8,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,212,1 -CS6800i/WLW176i,boiler,8,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,213,1 -CS6800i/WLW176i,boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,214,1 -CS6800i/WLW176i,boiler,8,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,215,1 -CS6800i/WLW176i,boiler,8,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,216,1 -CS6800i/WLW176i,boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,217,1 -CS6800i/WLW176i,boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,218,1 -CS6800i/WLW176i,boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,219,1 -CS6800i/WLW176i,boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,220,1 -CS6800i/WLW176i,boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,221,1 -CS6800i/WLW176i,boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,222,1 -CS6800i/WLW176i,boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,223,1 -CS6800i/WLW176i,boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,224,1 -CS6800i/WLW176i,boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,225,1 -CS6800i/WLW176i,boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,226,1 -CS6800i/WLW176i,boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,227,1 -CS6800i/WLW176i,boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,228,1 -CS6800i/WLW176i,boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,229,1 -CS6800i/WLW176i,boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,230,1 -CS6800i/WLW176i,boiler,8,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,231,1 -CS6800i/WLW176i,boiler,8,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,-1,1 -CS6800i/WLW176i,boiler,8,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,-1,1 -CS6800i/WLW176i,boiler,8,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,-1,1 -CS6800i/WLW176i,boiler,8,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,-1,1 -CS6800i/WLW176i,boiler,8,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,-1,1 -CS6800i/WLW176i,boiler,8,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,-1,1 -CS6800i/WLW176i,boiler,8,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1 -CS6800i/WLW176i,boiler,8,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1 -CS6800i/WLW176i,boiler,8,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1 -CS6800i/WLW176i,boiler,8,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1 -CS6800i/WLW176i,boiler,8,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1 -CS6800i/WLW176i,boiler,8,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1 -CS6800i/WLW176i,boiler,8,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1 -CS6800i/WLW176i,boiler,8,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1 -CS6800i/WLW176i,boiler,8,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1 -CS6800i/WLW176i,boiler,8,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1 -CS6800i/WLW176i,boiler,8,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1 -CS6800i/WLW176i,boiler,8,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1 -CS6800i/WLW176i,boiler,8,hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1 -CS6800i/WLW176i,boiler,8,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -CS6800i/WLW176i,boiler,8,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -CS6800i/WLW176i,boiler,8,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -CS6800i/WLW176i,boiler,8,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -CS6800i/WLW176i,boiler,8,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -CS6800i/WLW176i,boiler,8,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -CS6800i/WLW176i,boiler,8,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -CS6800i/WLW176i,boiler,8,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -CS6800i/WLW176i,boiler,8,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -CS6800i/WLW176i,boiler,8,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -CS6800i/WLW176i,boiler,8,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -CS6800i/WLW176i,boiler,8,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -CS6800i/WLW176i,boiler,8,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -CS6800i/WLW176i,boiler,8,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -CS6800i/WLW176i,boiler,8,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -CS6800i/WLW176i,boiler,8,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -CS6800i/WLW176i,boiler,8,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -CS6800i/WLW176i,boiler,8,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -CS6800i/WLW176i,boiler,8,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -CS6800i/WLW176i,boiler,8,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -CS6800i/WLW176i,boiler,8,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -CS6800i/WLW176i,boiler,8,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -CS6800i/WLW176i,boiler,8,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -CS6800i/WLW176i,boiler,8,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -CS6800i/WLW176i,boiler,8,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -CS6800i/WLW176i,boiler,8,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -CS6800i/WLW176i,boiler,8,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -CS6800i/WLW176i,boiler,8,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -CS6800i/WLW176i,boiler,8,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -CS6800i/WLW176i,boiler,8,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -CS6800i/WLW176i,boiler,8,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -CS6800i/WLW176i,boiler,8,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -CS6800i/WLW176i,boiler,8,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -CS6800i/WLW176i,boiler,8,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -CS6800i/WLW176i,boiler,8,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -CS6800i/WLW176i,boiler,8,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -CS6800i/WLW176i,boiler,8,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -CS6800i/WLW176i,boiler,8,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -CS6800i/WLW176i,boiler,8,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +CS5800i/CS6800i/WLW1x6i,boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +CS5800i/CS6800i/WLW1x6i,boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,82,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,264,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,84,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,86,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,88,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,90,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,266,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,92,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,94,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,96,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,98,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,100,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,102,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,104,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,coolingstarts,cooling control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,106,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,starts2,control starts2,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_control_starts2,sensor.boiler_dhw_starts2,5,9,1,6,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,poolstarts,pool control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,108,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,110,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,112,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,114,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconscomp,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,116,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,118,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,120,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,122,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,124,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,126,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,128,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgsupp,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,130,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,132,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,134,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,135,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpsetdiffpress,set differental pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differental_pressure,number.boiler_hpsetdiffpress,5,0,50,136,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,137,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpactivity,compressor activity,enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,138,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,139,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,140,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,141,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,142,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,143,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,144,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,145,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,146,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,147,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,148,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,149,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,150,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,151,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,152,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,153,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,154,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,155,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,156,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,157,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,158,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,159,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,160,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,161,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,162,8 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,170,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,171,8 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,179,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,180,8 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,188,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,189,8 +CS5800i/CS6800i/WLW1x6i,boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,197,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,198,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost,5,0,1,199,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,200,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,201,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,202,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxheaterstatus,aux heater status,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,203,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,204,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,205,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,206,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,207,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,208,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,209,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,210,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,211,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,212,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,213,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,214,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,215,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,216,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,217,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,218,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,219,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,220,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,221,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,222,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,223,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,224,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,225,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,226,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,227,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,228,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,229,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,230,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,231,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,268,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,269,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,270,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,271,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,272,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,273,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +CS5800i/CS6800i/WLW1x6i,boiler,8,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +CS5800i/CS6800i/WLW1x6i,boiler,8,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 C1200W,boiler,12,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 C1200W,boiler,12,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 C1200W,boiler,12,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -747,115 +747,115 @@ Logamax Plus GB022,boiler,84,nompower,nominal Power,uint8 (>=0<=254),kW,true,num Logamax Plus GB022,boiler,84,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 Logamax Plus GB022,boiler,84,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 Logamax Plus GB022,boiler,84,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 Topline/GB162,boiler,115,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 Topline/GB162,boiler,115,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 Topline/GB162,boiler,115,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -2200,12 +2200,12 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,229,1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,230,1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,231,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,-1,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,-1,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,-1,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,-1,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,-1,1 -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,-1,1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,268,1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,269,1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,270,1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,271,1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,272,1 +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,273,1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1 @@ -2403,12 +2403,12 @@ Geo 5xx,boiler,173,hpea0,condensate reservoir heating (EA0),boolean, ,false,bina Geo 5xx,boiler,173,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,229,1 Geo 5xx,boiler,173,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,230,1 Geo 5xx,boiler,173,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,231,1 -Geo 5xx,boiler,173,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,-1,1 -Geo 5xx,boiler,173,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,-1,1 -Geo 5xx,boiler,173,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,-1,1 -Geo 5xx,boiler,173,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,-1,1 -Geo 5xx,boiler,173,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,-1,1 -Geo 5xx,boiler,173,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,-1,1 +Geo 5xx,boiler,173,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,268,1 +Geo 5xx,boiler,173,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,269,1 +Geo 5xx,boiler,173,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,270,1 +Geo 5xx,boiler,173,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,271,1 +Geo 5xx,boiler,173,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,272,1 +Geo 5xx,boiler,173,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,273,1 Geo 5xx,boiler,173,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1 Geo 5xx,boiler,173,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1 Geo 5xx,boiler,173,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1 @@ -3205,115 +3205,115 @@ Greenstar HIU/Logamax kompakt WS170,boiler,219,mixertemp,mixer temperature,uint1 Greenstar HIU/Logamax kompakt WS170,boiler,219,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 Greenstar HIU/Logamax kompakt WS170,boiler,219,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 Greenstar HIU/Logamax kompakt WS170,boiler,219,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Logamax Plus GB122/Condense 2300,boiler,234,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -Logamax Plus GB122/Condense 2300,boiler,234,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -Logamax Plus GB122/Condense 2300,boiler,234,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -Logamax Plus GB122/Condense 2300,boiler,234,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -Logamax Plus GB122/Condense 2300,boiler,234,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -Logamax Plus GB122/Condense 2300,boiler,234,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -Logamax Plus GB122/Condense 2300,boiler,234,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -Logamax Plus GB122/Condense 2300,boiler,234,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -Logamax Plus GB122/Condense 2300,boiler,234,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -Logamax Plus GB122/Condense 2300,boiler,234,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -Logamax Plus GB122/Condense 2300,boiler,234,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -Logamax Plus GB122/Condense 2300,boiler,234,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -Logamax Plus GB122/Condense 2300,boiler,234,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -Logamax Plus GB122/Condense 2300,boiler,234,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 -Logamax Plus GB122/Condense 2300,boiler,234,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 -Logamax Plus GB122/Condense 2300,boiler,234,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 -Logamax Plus GB122/Condense 2300,boiler,234,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 -Logamax Plus GB122/Condense 2300,boiler,234,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 -Logamax Plus GB122/Condense 2300,boiler,234,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 -Logamax Plus GB122/Condense 2300,boiler,234,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 -Logamax Plus GB122/Condense 2300,boiler,234,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 -Logamax Plus GB122/Condense 2300,boiler,234,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 -Logamax Plus GB122/Condense 2300,boiler,234,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 -Logamax Plus GB122/Condense 2300,boiler,234,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 -Logamax Plus GB122/Condense 2300,boiler,234,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 -Logamax Plus GB122/Condense 2300,boiler,234,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 -Logamax Plus GB122/Condense 2300,boiler,234,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 -Logamax Plus GB122/Condense 2300,boiler,234,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 -Logamax Plus GB122/Condense 2300,boiler,234,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 -Logamax Plus GB122/Condense 2300,boiler,234,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 -Logamax Plus GB122/Condense 2300,boiler,234,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 -Logamax Plus GB122/Condense 2300,boiler,234,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 -Logamax Plus GB122/Condense 2300,boiler,234,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 -Logamax Plus GB122/Condense 2300,boiler,234,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 -Logamax Plus GB122/Condense 2300,boiler,234,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 -Logamax Plus GB122/Condense 2300,boiler,234,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -Logamax Plus GB122/Condense 2300,boiler,234,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -Logamax Plus GB122/Condense 2300,boiler,234,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -Logamax Plus GB122/Condense 2300,boiler,234,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -Logamax Plus GB122/Condense 2300,boiler,234,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -Logamax Plus GB122/Condense 2300,boiler,234,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -Logamax Plus GB122/Condense 2300,boiler,234,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 -Logamax Plus GB122/Condense 2300,boiler,234,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 -Logamax Plus GB122/Condense 2300,boiler,234,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 -Logamax Plus GB122/Condense 2300,boiler,234,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 -Logamax Plus GB122/Condense 2300,boiler,234,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 -Logamax Plus GB122/Condense 2300,boiler,234,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 -Logamax Plus GB122/Condense 2300,boiler,234,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 -Logamax Plus GB122/Condense 2300,boiler,234,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 -Logamax Plus GB122/Condense 2300,boiler,234,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 -Logamax Plus GB122/Condense 2300,boiler,234,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 -Logamax Plus GB122/Condense 2300,boiler,234,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 -Logamax Plus GB122/Condense 2300,boiler,234,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 -Logamax Plus GB122/Condense 2300,boiler,234,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 -Logamax Plus GB122/Condense 2300,boiler,234,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 -Logamax Plus GB122/Condense 2300,boiler,234,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 -Logamax Plus GB122/Condense 2300,boiler,234,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 -Logamax Plus GB122/Condense 2300,boiler,234,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 -Logamax Plus GB122/Condense 2300,boiler,234,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 -Logamax Plus GB122/Condense 2300,boiler,234,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 -Logamax Plus GB122/Condense 2300,boiler,234,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 -Logamax Plus GB122/Condense 2300,boiler,234,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 -Logamax Plus GB122/Condense 2300,boiler,234,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 -Logamax Plus GB122/Condense 2300,boiler,234,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 -Logamax Plus GB122/Condense 2300,boiler,234,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -Logamax Plus GB122/Condense 2300,boiler,234,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -Logamax Plus GB122/Condense 2300,boiler,234,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -Logamax Plus GB122/Condense 2300,boiler,234,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -Logamax Plus GB122/Condense 2300,boiler,234,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -Logamax Plus GB122/Condense 2300,boiler,234,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -Logamax Plus GB122/Condense 2300,boiler,234,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -Logamax Plus GB122/Condense 2300,boiler,234,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -Logamax Plus GB122/Condense 2300,boiler,234,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -Logamax Plus GB122/Condense 2300,boiler,234,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -Logamax Plus GB122/Condense 2300,boiler,234,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -Logamax Plus GB122/Condense 2300,boiler,234,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -Logamax Plus GB122/Condense 2300,boiler,234,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -Logamax Plus GB122/Condense 2300,boiler,234,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -Logamax Plus GB122/Condense 2300,boiler,234,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -Logamax Plus GB122/Condense 2300,boiler,234,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -Logamax Plus GB122/Condense 2300,boiler,234,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -Logamax Plus GB122/Condense 2300,boiler,234,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -Logamax Plus GB122/Condense 2300,boiler,234,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -Logamax Plus GB122/Condense 2300,boiler,234,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -Logamax Plus GB122/Condense 2300,boiler,234,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -Logamax Plus GB122/Condense 2300,boiler,234,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -Logamax Plus GB122/Condense 2300,boiler,234,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -Logamax Plus GB122/Condense 2300,boiler,234,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -Logamax Plus GB122/Condense 2300,boiler,234,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -Logamax Plus GB122/Condense 2300,boiler,234,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -Logamax Plus GB122/Condense 2300,boiler,234,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -Logamax Plus GB122/Condense 2300,boiler,234,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -Logamax Plus GB122/Condense 2300,boiler,234,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -Logamax Plus GB122/Condense 2300,boiler,234,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -Logamax Plus GB122/Condense 2300,boiler,234,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -Logamax Plus GB122/Condense 2300,boiler,234,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -Logamax Plus GB122/Condense 2300,boiler,234,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -Logamax Plus GB122/Condense 2300,boiler,234,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -Logamax Plus GB122/Condense 2300,boiler,234,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -Logamax Plus GB122/Condense 2300,boiler,234,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 -Logamax Plus GB122/Condense 2300,boiler,234,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 -Logamax Plus GB122/Condense 2300,boiler,234,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 -Logamax Plus GB122/Condense 2300,boiler,234,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 -Logamax Plus GB122/Condense 2300,boiler,234,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 -Logamax Plus GB122/Condense 2300,boiler,234,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 -Logamax Plus GB122/Condense 2300,boiler,234,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 -Logamax Plus GB122/Condense 2300,boiler,234,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,exhausttemp,exhaust temperature,uint16 (>=0<=3199),C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,5,0,1/10,232,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,5,0,1,233,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,5,0,1,234,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,flamecurr,flame current,uint16 (>=0<=3199),µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,5,0,1/10,235,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,5,0,1,236,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,5,0,1,237,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,5,0,1,238,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burnminpower,burner min power,uint8 (>=0<=100),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,5,0,1,239,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,5,0,1,240,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,5,0,1,241,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,absburnpow,burner current power (absolute),uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,5,0,1,242,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatblock,heating block,uint16 (>=0<=3199),C,false,sensor.boiler_heating_block,sensor.boiler_heatblock,5,0,1/10,243,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,5,0,1,244,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,5,0,1,245,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,5,0,1,246,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,5,0,1,247,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,5,0,1,248,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,5,0,1,249,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,5,0,1,250,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,5,0,1,251,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,5,0,1,252,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,5,0,1,253,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,23,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,24,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burnstarts,burner starts,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,25,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burnworkmin,total burner operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,27,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,burn2workmin,burner stage 2 operating time,time (>=0<=16777213),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,29,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatworkmin,total heat operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,31,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,heatstarts,burner starts heating,uint24 (>=0<=16777213), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,33,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,ubauptime,total UBA operating time,time (>=0<=16777213),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,35,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,37,28 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,65,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,67,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,68,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,70,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,71,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,72,6 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,78,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,79,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,90,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,254,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,256,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,starts,starts,uint24 (>=0<=16777213), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,workm,active time,time (>=0<=16777213),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,258,1 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,80,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,82,2 +Logamax Plus GB122/Condense 2300/Junkers Cerapur GC2200W 20/25C,boiler,234,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 Logamatic TC100/Moduline Easy,thermostat,202,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 Logamatic TC100/Moduline Easy,thermostat,202,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 Logamatic TC100/Moduline Easy,thermostat,202,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 @@ -3695,90 +3695,90 @@ RC25,thermostat,151,tempautotemp,temporary set temperature automode,uint8 (>=0<= RC25,thermostat,151,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 RC25,thermostat,151,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 RC25,thermostat,151,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 -RC200/CW100/CR120,thermostat,157,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -RC200/CW100/CR120,thermostat,157,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -RC200/CW100/CR120,thermostat,157,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -RC200/CW100/CR120,thermostat,157,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 -RC200/CW100/CR120,thermostat,157,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 -RC200/CW100/CR120,thermostat,157,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 -RC200/CW100/CR120,thermostat,157,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 -RC200/CW100/CR120,thermostat,157,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 -RC200/CW100/CR120,thermostat,157,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 -RC200/CW100/CR120,thermostat,157,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 -RC200/CW100/CR120,thermostat,157,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 -RC200/CW100/CR120,thermostat,157,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 -RC200/CW100/CR120,thermostat,157,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 -RC200/CW100/CR120,thermostat,157,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 -RC200/CW100/CR120,thermostat,157,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 -RC200/CW100/CR120,thermostat,157,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 -RC200/CW100/CR120,thermostat,157,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 -RC200/CW100/CR120,thermostat,157,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 -RC200/CW100/CR120,thermostat,157,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 -RC200/CW100/CR120,thermostat,157,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 -RC200/CW100/CR120,thermostat,157,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -RC200/CW100/CR120,thermostat,157,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -RC200/CW100/CR120,thermostat,157,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -RC200/CW100/CR120,thermostat,157,mode,operating mode,enum [manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -RC200/CW100/CR120,thermostat,157,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 -RC200/CW100/CR120,thermostat,157,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 -RC200/CW100/CR120,thermostat,157,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 -RC200/CW100/CR120,thermostat,157,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 -RC200/CW100/CR120,thermostat,157,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 -RC200/CW100/CR120,thermostat,157,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 -RC200/CW100/CR120,thermostat,157,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 -RC200/CW100/CR120,thermostat,157,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 -RC200/CW100/CR120,thermostat,157,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 -RC200/CW100/CR120,thermostat,157,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 -RC200/CW100/CR120,thermostat,157,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 -RC200/CW100/CR120,thermostat,157,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 -RC200/CW100/CR120,thermostat,157,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 -RC200/CW100/CR120,thermostat,157,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 -RC200/CW100/CR120,thermostat,157,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -RC200/CW100/CR120,thermostat,157,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 -RC200/CW100/CR120,thermostat,157,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 -RC200/CW100/CR120,thermostat,157,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 -RC200/CW100/CR120,thermostat,157,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 -RC200/CW100/CR120,thermostat,157,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 -RC200/CW100/CR120,thermostat,157,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 -RC200/CW100/CR120,thermostat,157,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 -RC200/CW100/CR120,thermostat,157,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 -RC200/CW100/CR120,thermostat,157,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 -RC200/CW100/CR120,thermostat,157,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 -RC200/CW100/CR120,thermostat,157,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 -RC200/CW100/CR120,thermostat,157,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 -RC200/CW100/CR120,thermostat,157,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 -RC200/CW100/CR120,thermostat,157,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 -RC200/CW100/CR120,thermostat,157,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 -RC200/CW100/CR120,thermostat,157,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 -RC200/CW100/CR120,thermostat,157,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 -RC200/CW100/CR120,thermostat,157,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 -RC200/CW100/CR120,thermostat,157,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 -RC200/CW100/CR120,thermostat,157,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 -RC200/CW100/CR120,thermostat,157,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 -RC200/CW100/CR120,thermostat,157,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 -RC200/CW100/CR120,thermostat,157,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 -RC200/CW100/CR120,thermostat,157,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 -RC200/CW100/CR120,thermostat,157,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 -RC200/CW100/CR120,thermostat,157,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 -RC200/CW100/CR120,thermostat,157,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 -RC200/CW100/CR120,thermostat,157,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 -RC200/CW100/CR120,thermostat,157,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 -RC200/CW100/CR120,thermostat,157,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 -RC200/CW100/CR120,thermostat,157,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 -RC200/CW100/CR120,thermostat,157,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 -RC200/CW100/CR120,thermostat,157,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 -RC200/CW100/CR120,thermostat,157,mode,operating mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 -RC200/CW100/CR120,thermostat,157,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 -RC200/CW100/CR120,thermostat,157,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 -RC200/CW100/CR120,thermostat,157,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 -RC200/CW100/CR120,thermostat,157,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 -RC200/CW100/CR120,thermostat,157,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 -RC200/CW100/CR120,thermostat,157,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 -RC200/CW100/CR120,thermostat,157,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 -RC200/CW100/CR120,thermostat,157,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 -RC200/CW100/CR120,thermostat,157,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 -RC200/CW100/CR120,thermostat,157,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 -RC200/CW100/CR120,thermostat,157,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 +RC200/CW100/CR120/CR50,thermostat,157,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +RC200/CW100/CR120/CR50,thermostat,157,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +RC200/CW100/CR120/CR50,thermostat,157,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +RC200/CW100/CR120/CR50,thermostat,157,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 +RC200/CW100/CR120/CR50,thermostat,157,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 +RC200/CW100/CR120/CR50,thermostat,157,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 +RC200/CW100/CR120/CR50,thermostat,157,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 +RC200/CW100/CR120/CR50,thermostat,157,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 +RC200/CW100/CR120/CR50,thermostat,157,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 +RC200/CW100/CR120/CR50,thermostat,157,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 +RC200/CW100/CR120/CR50,thermostat,157,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 +RC200/CW100/CR120/CR50,thermostat,157,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 +RC200/CW100/CR120/CR50,thermostat,157,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 +RC200/CW100/CR120/CR50,thermostat,157,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 +RC200/CW100/CR120/CR50,thermostat,157,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 +RC200/CW100/CR120/CR50,thermostat,157,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 +RC200/CW100/CR120/CR50,thermostat,157,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 +RC200/CW100/CR120/CR50,thermostat,157,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 +RC200/CW100/CR120/CR50,thermostat,157,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 +RC200/CW100/CR120/CR50,thermostat,157,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 +RC200/CW100/CR120/CR50,thermostat,157,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +RC200/CW100/CR120/CR50,thermostat,157,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +RC200/CW100/CR120/CR50,thermostat,157,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +RC200/CW100/CR120/CR50,thermostat,157,mode,operating mode,enum [manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +RC200/CW100/CR120/CR50,thermostat,157,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 +RC200/CW100/CR120/CR50,thermostat,157,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 +RC200/CW100/CR120/CR50,thermostat,157,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 +RC200/CW100/CR120/CR50,thermostat,157,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 +RC200/CW100/CR120/CR50,thermostat,157,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +RC200/CW100/CR120/CR50,thermostat,157,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 +RC200/CW100/CR120/CR50,thermostat,157,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 +RC200/CW100/CR120/CR50,thermostat,157,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 +RC200/CW100/CR120/CR50,thermostat,157,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 +RC200/CW100/CR120/CR50,thermostat,157,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 +RC200/CW100/CR120/CR50,thermostat,157,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 +RC200/CW100/CR120/CR50,thermostat,157,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 +RC200/CW100/CR120/CR50,thermostat,157,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 +RC200/CW100/CR120/CR50,thermostat,157,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 +RC200/CW100/CR120/CR50,thermostat,157,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 +RC200/CW100/CR120/CR50,thermostat,157,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 +RC200/CW100/CR120/CR50,thermostat,157,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 +RC200/CW100/CR120/CR50,thermostat,157,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 +RC200/CW100/CR120/CR50,thermostat,157,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 +RC200/CW100/CR120/CR50,thermostat,157,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 +RC200/CW100/CR120/CR50,thermostat,157,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 +RC200/CW100/CR120/CR50,thermostat,157,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 +RC200/CW100/CR120/CR50,thermostat,157,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 +RC200/CW100/CR120/CR50,thermostat,157,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 +RC200/CW100/CR120/CR50,thermostat,157,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 +RC200/CW100/CR120/CR50,thermostat,157,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 +RC200/CW100/CR120/CR50,thermostat,157,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 +RC200/CW100/CR120/CR50,thermostat,157,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 +RC200/CW100/CR120/CR50,thermostat,157,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 +RC200/CW100/CR120/CR50,thermostat,157,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 +RC200/CW100/CR120/CR50,thermostat,157,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 +RC200/CW100/CR120/CR50,thermostat,157,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 +RC200/CW100/CR120/CR50,thermostat,157,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 +RC200/CW100/CR120/CR50,thermostat,157,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 +RC200/CW100/CR120/CR50,thermostat,157,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 +RC200/CW100/CR120/CR50,thermostat,157,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 +RC200/CW100/CR120/CR50,thermostat,157,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 +RC200/CW100/CR120/CR50,thermostat,157,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 +RC200/CW100/CR120/CR50,thermostat,157,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 +RC200/CW100/CR120/CR50,thermostat,157,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 +RC200/CW100/CR120/CR50,thermostat,157,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 +RC200/CW100/CR120/CR50,thermostat,157,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 +RC200/CW100/CR120/CR50,thermostat,157,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 +RC200/CW100/CR120/CR50,thermostat,157,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 +RC200/CW100/CR120/CR50,thermostat,157,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 +RC200/CW100/CR120/CR50,thermostat,157,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 +RC200/CW100/CR120/CR50,thermostat,157,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 +RC200/CW100/CR120/CR50,thermostat,157,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 +RC200/CW100/CR120/CR50,thermostat,157,mode,operating mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 +RC200/CW100/CR120/CR50,thermostat,157,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 +RC200/CW100/CR120/CR50,thermostat,157,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 +RC200/CW100/CR120/CR50,thermostat,157,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 +RC200/CW100/CR120/CR50,thermostat,157,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 +RC200/CW100/CR120/CR50,thermostat,157,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 +RC200/CW100/CR120/CR50,thermostat,157,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 +RC200/CW100/CR120/CR50,thermostat,157,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 +RC200/CW100/CR120/CR50,thermostat,157,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 +RC200/CW100/CR120/CR50,thermostat,157,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 +RC200/CW100/CR120/CR50,thermostat,157,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 +RC200/CW100/CR120/CR50,thermostat,157,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 @@ -3863,90 +3863,90 @@ RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,disinfectda RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 -RC100/Moduline 1000/1010,thermostat,165,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -RC100/Moduline 1000/1010,thermostat,165,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -RC100/Moduline 1000/1010,thermostat,165,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -RC100/Moduline 1000/1010,thermostat,165,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 -RC100/Moduline 1000/1010,thermostat,165,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 -RC100/Moduline 1000/1010,thermostat,165,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 -RC100/Moduline 1000/1010,thermostat,165,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 -RC100/Moduline 1000/1010,thermostat,165,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 -RC100/Moduline 1000/1010,thermostat,165,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 -RC100/Moduline 1000/1010,thermostat,165,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 -RC100/Moduline 1000/1010,thermostat,165,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 -RC100/Moduline 1000/1010,thermostat,165,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 -RC100/Moduline 1000/1010,thermostat,165,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 -RC100/Moduline 1000/1010,thermostat,165,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 -RC100/Moduline 1000/1010,thermostat,165,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 -RC100/Moduline 1000/1010,thermostat,165,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 -RC100/Moduline 1000/1010,thermostat,165,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 -RC100/Moduline 1000/1010,thermostat,165,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 -RC100/Moduline 1000/1010,thermostat,165,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 -RC100/Moduline 1000/1010,thermostat,165,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 -RC100/Moduline 1000/1010,thermostat,165,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -RC100/Moduline 1000/1010,thermostat,165,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -RC100/Moduline 1000/1010,thermostat,165,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -RC100/Moduline 1000/1010,thermostat,165,mode,operating mode,enum [manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -RC100/Moduline 1000/1010,thermostat,165,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 -RC100/Moduline 1000/1010,thermostat,165,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 -RC100/Moduline 1000/1010,thermostat,165,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 -RC100/Moduline 1000/1010,thermostat,165,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 -RC100/Moduline 1000/1010,thermostat,165,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 -RC100/Moduline 1000/1010,thermostat,165,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 -RC100/Moduline 1000/1010,thermostat,165,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 -RC100/Moduline 1000/1010,thermostat,165,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 -RC100/Moduline 1000/1010,thermostat,165,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 -RC100/Moduline 1000/1010,thermostat,165,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 -RC100/Moduline 1000/1010,thermostat,165,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 -RC100/Moduline 1000/1010,thermostat,165,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 -RC100/Moduline 1000/1010,thermostat,165,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 -RC100/Moduline 1000/1010,thermostat,165,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 -RC100/Moduline 1000/1010,thermostat,165,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -RC100/Moduline 1000/1010,thermostat,165,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 -RC100/Moduline 1000/1010,thermostat,165,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 -RC100/Moduline 1000/1010,thermostat,165,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 -RC100/Moduline 1000/1010,thermostat,165,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 -RC100/Moduline 1000/1010,thermostat,165,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 -RC100/Moduline 1000/1010,thermostat,165,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 -RC100/Moduline 1000/1010,thermostat,165,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 -RC100/Moduline 1000/1010,thermostat,165,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 -RC100/Moduline 1000/1010,thermostat,165,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 -RC100/Moduline 1000/1010,thermostat,165,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 -RC100/Moduline 1000/1010,thermostat,165,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 -RC100/Moduline 1000/1010,thermostat,165,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 -RC100/Moduline 1000/1010,thermostat,165,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 -RC100/Moduline 1000/1010,thermostat,165,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 -RC100/Moduline 1000/1010,thermostat,165,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 -RC100/Moduline 1000/1010,thermostat,165,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 -RC100/Moduline 1000/1010,thermostat,165,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 -RC100/Moduline 1000/1010,thermostat,165,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 -RC100/Moduline 1000/1010,thermostat,165,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 -RC100/Moduline 1000/1010,thermostat,165,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 -RC100/Moduline 1000/1010,thermostat,165,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 -RC100/Moduline 1000/1010,thermostat,165,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 -RC100/Moduline 1000/1010,thermostat,165,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 -RC100/Moduline 1000/1010,thermostat,165,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 -RC100/Moduline 1000/1010,thermostat,165,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 -RC100/Moduline 1000/1010,thermostat,165,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 -RC100/Moduline 1000/1010,thermostat,165,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 -RC100/Moduline 1000/1010,thermostat,165,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 -RC100/Moduline 1000/1010,thermostat,165,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 -RC100/Moduline 1000/1010,thermostat,165,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 -RC100/Moduline 1000/1010,thermostat,165,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 -RC100/Moduline 1000/1010,thermostat,165,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 -RC100/Moduline 1000/1010,thermostat,165,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 -RC100/Moduline 1000/1010,thermostat,165,mode,operating mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 -RC100/Moduline 1000/1010,thermostat,165,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 -RC100/Moduline 1000/1010,thermostat,165,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 -RC100/Moduline 1000/1010,thermostat,165,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 -RC100/Moduline 1000/1010,thermostat,165,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 -RC100/Moduline 1000/1010,thermostat,165,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 -RC100/Moduline 1000/1010,thermostat,165,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 -RC100/Moduline 1000/1010,thermostat,165,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 -RC100/Moduline 1000/1010,thermostat,165,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 -RC100/Moduline 1000/1010,thermostat,165,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 -RC100/Moduline 1000/1010,thermostat,165,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 -RC100/Moduline 1000/1010,thermostat,165,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +RC100/CR10/Moduline 1000/1010,thermostat,165,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +RC100/CR10/Moduline 1000/1010,thermostat,165,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +RC100/CR10/Moduline 1000/1010,thermostat,165,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,mode,operating mode,enum [manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,mode,operating mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 +RC100/CR10/Moduline 1000/1010,thermostat,165,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 Rego 2000/3000,thermostat,172,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 Rego 2000/3000,thermostat,172,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 Rego 2000/3000,thermostat,172,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 @@ -4059,90 +4059,90 @@ Comfort+2RF,thermostat,246,haclimate,mqtt discovery current room temperature,enu Comfort+2RF,thermostat,246,mode,operating mode,enum [auto\|off], ,false,sensor.thermostat_hc1_operating_mode,sensor.thermostat_hc1_mode,6,1,1,3,1 Comfort+2RF,thermostat,246,modetype,mode type,enum [off\|on], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 Comfort+2RF,thermostat,246,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,mode,operating mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,control,control device,enum [off\|-\|RC100\|RC100H\|-\|RC120RF\|RC220/RT800\|single], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,mode,operating mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 -Rego 3000/UI800/WSW196i/BC400,thermostat,253,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset,6,0,1/10,46,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry,6,0,1,47,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp,6,0,1/10,48,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp,6,0,1,49,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building,6,0,1,50,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp,6,0,1,51,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping,6,0,1,52,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy,6,0,1,53,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp,6,0,1,54,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio,6,0,1/10,55,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor,6,0,1/10,56,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor,6,0,1/10,57,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler,6,0,1,58,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler,6,0,1,59,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw,6,0,1,60,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,6,0,1,61,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,6,0,1,62,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp,6,1,1/2,0,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp,6,1,1/10,1,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate,6,1,1,2,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,mode,operating mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_operating_mode,select.thermostat_hc1_mode,6,1,1,3,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype,6,1,1,4,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp,6,1,1/2,5,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp,6,1,1/2,6,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp,6,1,1/2,7,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp,6,1,1,9,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp,6,1,1,10,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp,6,1,1,11,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp,6,1,1,12,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence,6,1,1,13,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor,6,1,1/10,14,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl,6,1,1/10,15,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode,6,1,1,16,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp,6,1,1,17,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype,6,1,1,19,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode,6,1,1,20,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode,6,1,1,21,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode,6,1,1,22,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate,6,1,1,23,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,controlmode,control mode,enum [weather compensated\|outside basepoint\|n/a\|room\|power\|constant], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode,6,1,1,24,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp,6,1,1/2,26,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,remoteseltemp,temporary set temperature from remote,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_from_remote,number.thermostat_hc1_remoteseltemp,6,1,1/2,27,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup,6,1,1,28,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode,6,1,1,30,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp,6,1,1,31,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp,6,1,1,32,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio,6,1,1,33,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hpcooling,hp cooling,boolean, ,true,switch.thermostat_hc1_hp_cooling,switch.thermostat_hc1_hpcooling,6,1,1,34,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,coolingon,cooling on,boolean, ,false,binary_sensor.thermostat_hc1_cooling_on,binary_sensor.thermostat_hc1_coolingon,6,1,1,35,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hpmode,HP Mode,enum [heating\|cooling\|heating & cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode,6,1,1,36,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset,6,1,1,37,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff,6,1,1,38,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp,6,1,1,39,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,control,control device,enum [off\|-\|RC100\|RC100H\|-\|RC120RF\|RC220/RT800\|single], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control,6,1,1,40,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,remotehum,room humidity from remote,cmd [] (>=-1<=101),%,true,sensor.thermostat_hc1_room_humidity_from_remote,sensor.thermostat_hc1_remotehum,6,1,1,42,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay,6,1,1,43,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay,6,1,1,44,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart,6,1,1,45,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost,6,1,1,46,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime,6,1,1,47,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,coolstart,cooling starttemp,uint8 (>=20<=35),C,true,number.thermostat_hc1_cooling_starttemp,number.thermostat_hc1_coolstart,6,1,1,193,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,coolondelay,cooling on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_on_delay,number.thermostat_hc1_coolondelay,6,1,1,194,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,cooloffdelay,cooling off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_cooling_off_delay,number.thermostat_hc1_cooloffdelay,6,1,1,195,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,switchprogmode,switch program mode,enum [level\|absolute], ,true,select.thermostat_hc1_switch_program_mode,select.thermostat_hc1_switchprogmode,6,1,1,196,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,mode,operating mode,enum [off\|eco+\|eco\|comfort\|auto], ,true,select.thermostat_dhw_operating_mode,select.thermostat_dhw_mode,6,9,1,0,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp,6,9,1,1,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow,6,9,1,2,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode,6,9,1,3,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration,6,9,15,4,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge,6,9,1,5,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra,6,9,1,6,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting,6,9,1,7,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday,6,9,1,8,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime,6,9,15,9,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating,6,9,1,10,1 +Rego 3000/UI800/WSW1x6i/BC400,thermostat,253,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime,6,9,15,11,1 ES72/RC20,thermostat,66,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,6,0,1,0,8 ES72/RC20,thermostat,66,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,6,0,1,8,25 ES72/RC20,thermostat,66,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime,6,0,1,33,13 @@ -4328,7 +4328,7 @@ FW100,thermostat,105,control,control device,enum [off\|FB10\|FB100], ,true,selec FW100,thermostat,105,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 FW100,thermostat,105,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 FW100,thermostat,105,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -FW100,thermostat,105,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +FW100,thermostat,105,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1/2,8,1 FW100,thermostat,105,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor,6,1,1,191,1 FW100,thermostat,105,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode,6,1,1,51,1 FW100,thermostat,105,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 @@ -4363,7 +4363,7 @@ FW200,thermostat,106,control,control device,enum [off\|FB10\|FB100], ,true,selec FW200,thermostat,106,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 FW200,thermostat,106,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 FW200,thermostat,106,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -FW200,thermostat,106,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +FW200,thermostat,106,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1/2,8,1 FW200,thermostat,106,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor,6,1,1,191,1 FW200,thermostat,106,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode,6,1,1,51,1 FW200,thermostat,106,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 @@ -4398,7 +4398,7 @@ FR100,thermostat,107,control,control device,enum [off\|FB10\|FB100], ,true,selec FR100,thermostat,107,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 FR100,thermostat,107,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 FR100,thermostat,107,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -FR100,thermostat,107,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +FR100,thermostat,107,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1/2,8,1 FR100,thermostat,107,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor,6,1,1,191,1 FR100,thermostat,107,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode,6,1,1,51,1 FR100,thermostat,107,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 @@ -4433,7 +4433,7 @@ FR110,thermostat,108,control,control device,enum [off\|FB10\|FB100], ,true,selec FR110,thermostat,108,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 FR110,thermostat,108,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 FR110,thermostat,108,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -FR110,thermostat,108,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +FR110,thermostat,108,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1/2,8,1 FR110,thermostat,108,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor,6,1,1,191,1 FR110,thermostat,108,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode,6,1,1,51,1 FR110,thermostat,108,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 @@ -4468,7 +4468,7 @@ FB10,thermostat,109,control,control device,enum [off\|FB10\|FB100], ,true,select FB10,thermostat,109,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 FB10,thermostat,109,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 FB10,thermostat,109,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -FB10,thermostat,109,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +FB10,thermostat,109,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1/2,8,1 FB10,thermostat,109,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor,6,1,1,191,1 FB10,thermostat,109,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode,6,1,1,51,1 FB10,thermostat,109,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 @@ -4503,7 +4503,7 @@ FB100,thermostat,110,control,control device,enum [off\|FB10\|FB100], ,true,selec FB100,thermostat,110,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 FB100,thermostat,110,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 FB100,thermostat,110,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -FB100,thermostat,110,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +FB100,thermostat,110,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1/2,8,1 FB100,thermostat,110,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor,6,1,1,191,1 FB100,thermostat,110,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode,6,1,1,51,1 FB100,thermostat,110,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 @@ -4538,7 +4538,7 @@ FR10,thermostat,111,control,control device,enum [off\|FB10\|FB100], ,true,select FR10,thermostat,111,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 FR10,thermostat,111,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 FR10,thermostat,111,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -FR10,thermostat,111,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +FR10,thermostat,111,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1/2,8,1 FR10,thermostat,111,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor,6,1,1,191,1 FR10,thermostat,111,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode,6,1,1,51,1 FR10,thermostat,111,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 @@ -4573,7 +4573,7 @@ FW500,thermostat,116,control,control device,enum [off\|FB10\|FB100], ,true,selec FW500,thermostat,116,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 FW500,thermostat,116,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 FW500,thermostat,116,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -FW500,thermostat,116,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +FW500,thermostat,116,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1/2,8,1 FW500,thermostat,116,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor,6,1,1,191,1 FW500,thermostat,116,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode,6,1,1,51,1 FW500,thermostat,116,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 @@ -4608,7 +4608,7 @@ FR50,thermostat,147,control,control device,enum [off\|FB10\|FB100], ,true,select FR50,thermostat,147,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 FR50,thermostat,147,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 FR50,thermostat,147,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -FR50,thermostat,147,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +FR50,thermostat,147,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1/2,8,1 FR50,thermostat,147,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor,6,1,1,191,1 FR50,thermostat,147,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode,6,1,1,51,1 FR50,thermostat,147,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 @@ -4643,7 +4643,7 @@ FR120,thermostat,191,control,control device,enum [off\|FB10\|FB100], ,true,selec FR120,thermostat,191,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 FR120,thermostat,191,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 FR120,thermostat,191,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -FR120,thermostat,191,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +FR120,thermostat,191,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1/2,8,1 FR120,thermostat,191,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor,6,1,1,191,1 FR120,thermostat,191,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode,6,1,1,51,1 FR120,thermostat,191,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 @@ -4678,7 +4678,7 @@ FW120,thermostat,192,control,control device,enum [off\|FB10\|FB100], ,true,selec FW120,thermostat,192,program,program,enum [prog a\|prog b\|prog c\|prog d\|prog e\|prog f], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program,6,1,1,25,1 FW120,thermostat,192,remotetemp,room temperature from remote,cmd [] (>=-1<=101),C,true,sensor.thermostat_hc1_room_temperature_from_remote,sensor.thermostat_hc1_remotetemp,6,1,1/10,41,1 FW120,thermostat,192,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp,6,1,1,18,1 -FW120,thermostat,192,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1,8,1 +FW120,thermostat,192,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp,6,1,1/2,8,1 FW120,thermostat,192,roomsensor,room sensor,enum [extern\|intern\|auto], ,true,select.thermostat_hc1_room_sensor,select.thermostat_hc1_roomsensor,6,1,1,191,1 FW120,thermostat,192,holidaymode,holiday mode,enum [nofrost\|eco\|heat\|auto], ,true,select.thermostat_hc1_holiday_mode,select.thermostat_hc1_holidaymode,6,1,1,51,1 FW120,thermostat,192,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization,6,1,1,29,1 diff --git a/dump_telegrams.csv b/dump_telegrams.csv index 07a0404a3..3da684602 100644 --- a/dump_telegrams.csv +++ b/dump_telegrams.csv @@ -107,7 +107,7 @@ telegram_type_id,name,is_fetched 0x02A2,RC300Curves, 0x02A5,RC300Monitor, 0x02A6,RC300Monitor, -0x02A7,RC300Monitor, +0x02A7,CRFMonitor, 0x02A8,RC300Monitor, 0x02A9,RC300Monitor, 0x02AA,RC300Monitor, diff --git a/interface/eslint.config.js b/interface/eslint.config.js index c6d578b18..281c28372 100644 --- a/interface/eslint.config.js +++ b/interface/eslint.config.js @@ -16,7 +16,7 @@ export default tseslint.config( } }, { - ignores: ['dist/*', '*.js', '**/*.cjs', '**/unpack.ts', 'i18n*.*'] + ignores: ['dist/*', 'build/*', '*.js', '**/*.cjs', '**/unpack.ts', 'i18n*.*'] }, { rules: { diff --git a/interface/package.json b/interface/package.json index f10624f8a..01082ee23 100644 --- a/interface/package.json +++ b/interface/package.json @@ -24,14 +24,14 @@ "@alova/adapter-xhr": "2.0.7", "@emotion/react": "^11.13.3", "@emotion/styled": "^11.13.0", - "@mui/icons-material": "^6.1.1", - "@mui/material": "^6.1.1", + "@mui/icons-material": "^6.1.2", + "@mui/material": "^6.1.2", "@table-library/react-table-library": "4.1.7", "alova": "3.0.17", "async-validator": "^4.2.5", "jwt-decode": "^4.0.0", "mime-types": "^2.1.35", - "preact": "^10.24.1", + "preact": "^10.24.2", "react": "^18.3.1", "react-dom": "^18.3.1", "react-icons": "^5.3.0", @@ -41,18 +41,18 @@ "typescript": "^5.6.2" }, "devDependencies": { - "@babel/core": "^7.25.2", - "@eslint/js": "^9.11.1", + "@babel/core": "^7.25.7", + "@eslint/js": "^9.12.0", "@preact/compat": "^18.3.1", "@preact/preset-vite": "^2.9.1", "@trivago/prettier-plugin-sort-imports": "^4.3.0", "@types/formidable": "^3", "@types/node": "^22.7.4", - "@types/react": "^18.3.10", + "@types/react": "^18.3.11", "@types/react-dom": "^18.3.0", "@types/react-router-dom": "^5.3.3", "concurrently": "^9.0.1", - "eslint": "^9.11.1", + "eslint": "^9.12.0", "eslint-config-prettier": "^9.1.0", "formidable": "^3.5.1", "prettier": "^3.3.3", diff --git a/interface/src/app/main/CustomEntitiesDialog.tsx b/interface/src/app/main/CustomEntitiesDialog.tsx index 757163f9b..becc5f65d 100644 --- a/interface/src/app/main/CustomEntitiesDialog.tsx +++ b/interface/src/app/main/CustomEntitiesDialog.tsx @@ -277,7 +277,7 @@ const CustomEntitiesDialog = ({ select > {DeviceValueUOM_s.map((val, i) => ( - + {val} ))} diff --git a/interface/src/app/main/Devices.tsx b/interface/src/app/main/Devices.tsx index 890d29f8f..fe306dbda 100644 --- a/interface/src/app/main/Devices.tsx +++ b/interface/src/app/main/Devices.tsx @@ -310,7 +310,7 @@ const Devices = () => { }, [escFunction]); const customize = () => { - if (selectedDevice == 99) { + if (selectedDevice === 99) { navigate('/customentities'); } else { navigate('/customizations', { state: selectedDevice }); diff --git a/interface/src/app/main/DevicesDialog.tsx b/interface/src/app/main/DevicesDialog.tsx index e668da663..e21afaf84 100644 --- a/interface/src/app/main/DevicesDialog.tsx +++ b/interface/src/app/main/DevicesDialog.tsx @@ -162,7 +162,7 @@ const DevicesDialog = ({ value={editItem.v} disabled={!writeable} sx={{ width: '30ch' }} - multiline={editItem.u ? false : true} + multiline={!editItem.u} onChange={updateFormValue} /> )} diff --git a/interface/src/app/main/Modules.tsx b/interface/src/app/main/Modules.tsx index cb366715f..2fa7c1f79 100644 --- a/interface/src/app/main/Modules.tsx +++ b/interface/src/app/main/Modules.tsx @@ -29,7 +29,7 @@ import { useI18nContext } from 'i18n/i18n-react'; import { readModules, writeModules } from '../../api/app'; import ModulesDialog from './ModulesDialog'; -import type { ModuleItem, Modules } from './types'; +import type { ModuleItem } from './types'; const Modules = () => { const { LL } = useI18nContext(); @@ -39,6 +39,8 @@ const Modules = () => { const [selectedModuleItem, setSelectedModuleItem] = useState(); const [dialogOpen, setDialogOpen] = useState(false); + useLayoutTitle(LL.MODULES()); + const { data: modules, send: fetchModules, @@ -155,8 +157,6 @@ const Modules = () => { return ; } - useLayoutTitle(LL.MODULES()); - if (modules.length === 0) { return ( diff --git a/interface/src/app/main/Scheduler.tsx b/interface/src/app/main/Scheduler.tsx index b2a526560..9b70faccf 100644 --- a/interface/src/app/main/Scheduler.tsx +++ b/interface/src/app/main/Scheduler.tsx @@ -43,6 +43,8 @@ const Scheduler = () => { const [creating, setCreating] = useState(false); const [dialogOpen, setDialogOpen] = useState(false); + useLayoutTitle(LL.SCHEDULER()); + const { data: schedule, send: fetchSchedule, @@ -243,8 +245,6 @@ const Scheduler = () => { ); - useLayoutTitle(LL.SCHEDULER()); - return ( @@ -318,9 +316,7 @@ const SchedulerDialog = ({ } multiline fullWidth - value={ - editItem.time == '00:00' ? (editItem.time = '') : editItem.time - } + value={editItem.time === '00:00' ? '' : editItem.time} margin="normal" onChange={updateFormValue} /> diff --git a/interface/src/app/main/Sensors.tsx b/interface/src/app/main/Sensors.tsx index 7833e3066..bfaf10d19 100644 --- a/interface/src/app/main/Sensors.tsx +++ b/interface/src/app/main/Sensors.tsx @@ -150,6 +150,56 @@ const Sensors = () => { } ]); + const RenderTemperatureSensors = () => ( +
+ {(tableList: TemperatureSensor[]) => ( + <> +
+ + + + + + + + +
+ + {tableList.map((ts: TemperatureSensor) => ( + updateTemperatureSensor(ts)}> + {ts.n} + {formatValue(ts.t, ts.u)} + + ))} + + + )} +
+ ); + const getSortIcon = (state: State, sortKey: unknown) => { if (state.sortKey === sortKey && state.reverse) { return ; @@ -332,56 +382,6 @@ const Sensors = () => { }); }; - const RenderTemperatureSensors = () => ( - - {(tableList: TemperatureSensor[]) => ( - <> -
- - - - - - - - -
- - {tableList.map((ts: TemperatureSensor) => ( - updateTemperatureSensor(ts)}> - {ts.n} - {formatValue(ts.t, ts.u)} - - ))} - - - )} -
- ); - const RenderAnalogSensors = () => ( {AnalogTypeNames.map((val, i) => ( - + {val} ))} @@ -143,7 +143,7 @@ const SensorsAnalogDialog = ({ onChange={updateFormValue} > {DeviceValueUOM_s.map((val, i) => ( - + {val} ))} diff --git a/interface/src/app/main/types.ts b/interface/src/app/main/types.ts index 1efa9bfc8..3681f8e09 100644 --- a/interface/src/app/main/types.ts +++ b/interface/src/app/main/types.ts @@ -206,15 +206,15 @@ export const DeviceValueUOM_s = [ export enum AnalogType { REMOVED = -1, NOTUSED = 0, - DIGITAL_IN, - COUNTER, - ADC, - TIMER, - RATE, - DIGITAL_OUT, - PWM_0, - PWM_1, - PWM_2 + DIGITAL_IN = 1, + COUNTER = 2, + ADC = 3, + TIMER = 4, + RATE = 5, + DIGITAL_OUT = 6, + PWM_0 = 7, + PWM_1 = 8, + PWM_2 = 9 } export const AnalogTypeNames = [ @@ -296,7 +296,7 @@ export interface ScheduleItem { active: boolean; deleted?: boolean; flags: number; - time: string; + time: string; // also used for Condition and On Change cmd: string; value: string; name: string; // is optional diff --git a/interface/src/app/status/APStatus.tsx b/interface/src/app/status/APStatus.tsx index 5f548472f..ee6bc22ab 100644 --- a/interface/src/app/status/APStatus.tsx +++ b/interface/src/app/status/APStatus.tsx @@ -35,7 +35,7 @@ export const apStatusHighlight = ({ status }: APStatusType, theme: Theme) => { const APStatus = () => { const { - data: data, + data, send: loadData, error } = useAutoRequest(APApi.readAPStatus, { pollingTime: 5000 }); diff --git a/interface/src/app/status/Activity.tsx b/interface/src/app/status/Activity.tsx index 27d01a1fa..b91073fc6 100644 --- a/interface/src/app/status/Activity.tsx +++ b/interface/src/app/status/Activity.tsx @@ -18,7 +18,7 @@ import type { Stat } from '../main/types'; const SystemActivity = () => { const { - data: data, + data, send: loadData, error } = useAutoRequest(readActivity, { pollingTime: 2000 }); diff --git a/interface/src/app/status/HardwareStatus.tsx b/interface/src/app/status/HardwareStatus.tsx index 7637861cd..50b21dc3e 100644 --- a/interface/src/app/status/HardwareStatus.tsx +++ b/interface/src/app/status/HardwareStatus.tsx @@ -33,7 +33,7 @@ const HardwareStatus = () => { useLayoutTitle(LL.STATUS_OF(LL.HARDWARE())); const { - data: data, + data, send: loadData, error } = useAutoRequest(SystemApi.readSystemStatus, { pollingTime: 2000 }); @@ -50,6 +50,7 @@ const HardwareStatus = () => { {data.model ? ( BBQKees @@ -93,7 +94,7 @@ const HardwareStatus = () => { ' (rev.' + data.cpu_rev + ', ' + - (data.cpu_cores == 1 ? 'single-core)' : 'dual-core)') + + (data.cpu_cores === 1 ? 'single-core)' : 'dual-core)') + ' @ ' + data.cpu_freq_mhz + ' Mhz' diff --git a/interface/src/app/status/MqttStatus.tsx b/interface/src/app/status/MqttStatus.tsx index cf2943707..a1096f724 100644 --- a/interface/src/app/status/MqttStatus.tsx +++ b/interface/src/app/status/MqttStatus.tsx @@ -55,7 +55,7 @@ export const mqttQueueHighlight = ( const MqttStatus = () => { const { - data: data, + data, send: loadData, error } = useAutoRequest(MqttApi.readMqttStatus, { pollingTime: 5000 }); diff --git a/interface/src/app/status/NTPStatus.tsx b/interface/src/app/status/NTPStatus.tsx index 75d696550..757d65225 100644 --- a/interface/src/app/status/NTPStatus.tsx +++ b/interface/src/app/status/NTPStatus.tsx @@ -37,7 +37,7 @@ import { formatDateTime, formatLocalDateTime } from 'utils'; const NTPStatus = () => { const { - data: data, + data, send: loadData, error } = useAutoRequest(NTPApi.readNTPStatus, { pollingTime: 5000 }); diff --git a/interface/src/app/status/NetworkStatus.tsx b/interface/src/app/status/NetworkStatus.tsx index 812f8f537..92d9dff18 100644 --- a/interface/src/app/status/NetworkStatus.tsx +++ b/interface/src/app/status/NetworkStatus.tsx @@ -82,7 +82,7 @@ const IPs = (status: NetworkStatusType) => { const NetworkStatus = () => { const { - data: data, + data, send: loadData, error } = useAutoRequest(NetworkApi.readNetworkStatus, { pollingTime: 5000 }); diff --git a/interface/src/app/status/Status.tsx b/interface/src/app/status/Status.tsx index 51241c04d..74a6f6747 100644 --- a/interface/src/app/status/Status.tsx +++ b/interface/src/app/status/Status.tsx @@ -60,7 +60,7 @@ const SystemStatus = () => { }); const { - data: data, + data, send: loadData, error } = useAutoRequest(readSystemStatus, { diff --git a/interface/src/app/status/SystemLog.tsx b/interface/src/app/status/SystemLog.tsx index 7aaeea32c..8028cb98e 100644 --- a/interface/src/app/status/SystemLog.tsx +++ b/interface/src/app/status/SystemLog.tsx @@ -250,7 +250,7 @@ const SystemLog = () => { }} > {logEntries.map((e) => ( -
+
{e.t} {paddedLevelLabel(e.l)}  {paddedIDLabel(e.i)} diff --git a/interface/src/components/inputs/ValidatedTextField.tsx b/interface/src/components/inputs/ValidatedTextField.tsx index b871a5d9f..9fdcdab5d 100644 --- a/interface/src/components/inputs/ValidatedTextField.tsx +++ b/interface/src/components/inputs/ValidatedTextField.tsx @@ -19,7 +19,7 @@ const ValidatedTextField: FC = ({ const errors = fieldErrors && fieldErrors[rest.name]; const renderErrors = () => errors && - errors.map((e, i) => {e.message}); + errors.map((e) => {e.message}); return ( <> diff --git a/interface/src/components/layout/Layout.tsx b/interface/src/components/layout/Layout.tsx index a552ea915..a11d194d4 100644 --- a/interface/src/components/layout/Layout.tsx +++ b/interface/src/components/layout/Layout.tsx @@ -25,6 +25,7 @@ const Layout: FC = ({ children }) => { useEffect(() => setMobileOpen(false), [pathname]); return ( + // TODO wrap title/setTitle in a useMemo() diff --git a/interface/src/contexts/authentication/Authentication.tsx b/interface/src/contexts/authentication/Authentication.tsx index 632b0cc3b..ff2c77395 100644 --- a/interface/src/contexts/authentication/Authentication.tsx +++ b/interface/src/contexts/authentication/Authentication.tsx @@ -69,6 +69,7 @@ const Authentication: FC = ({ children }) => { if (initialized) { return ( + // TODO useMemo? ( options?: ValidateOption ): Promise => new Promise((resolve, reject) => { - void validator.validate( - source, - options ? options : {}, - (errors, fieldErrors) => { - if (errors) { - reject(fieldErrors as Error); - } else { - resolve(source as T); - } + void validator.validate(source, options || {}, (errors, fieldErrors) => { + if (errors) { + reject(fieldErrors as Error); + } else { + resolve(source as T); } - ); + }); }); // updated to support both IPv4 and IPv6 diff --git a/interface/yarn.lock b/interface/yarn.lock index 34380ea50..fc0860f80 100644 --- a/interface/yarn.lock +++ b/interface/yarn.lock @@ -43,6 +43,16 @@ __metadata: languageName: node linkType: hard +"@babel/code-frame@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/code-frame@npm:7.25.7" + dependencies: + "@babel/highlight": "npm:^7.25.7" + picocolors: "npm:^1.0.0" + checksum: 10c0/14825c298bdec914caf3d24d1383b6d4cd6b030714686004992f4fc251831ecf432236652896f99d5d341f17170ae9a07b58d8d7b15aa0df8cfa1c5a7d5474bc + languageName: node + linkType: hard + "@babel/compat-data@npm:^7.25.2": version: 7.25.4 resolution: "@babel/compat-data@npm:7.25.4" @@ -50,7 +60,14 @@ __metadata: languageName: node linkType: hard -"@babel/core@npm:^7.22.1, @babel/core@npm:^7.25.2": +"@babel/compat-data@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/compat-data@npm:7.25.7" + checksum: 10c0/e5cc915abdd18d021236474a96606b2d4a915c4fb620c1ad776b8a08d91111e788cb3b7e9bad43593d4e0bfa4f06894357bcb0984102de1861b9e7322b6bc9f8 + languageName: node + linkType: hard + +"@babel/core@npm:^7.22.1": version: 7.25.2 resolution: "@babel/core@npm:7.25.2" dependencies: @@ -73,6 +90,29 @@ __metadata: languageName: node linkType: hard +"@babel/core@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/core@npm:7.25.7" + dependencies: + "@ampproject/remapping": "npm:^2.2.0" + "@babel/code-frame": "npm:^7.25.7" + "@babel/generator": "npm:^7.25.7" + "@babel/helper-compilation-targets": "npm:^7.25.7" + "@babel/helper-module-transforms": "npm:^7.25.7" + "@babel/helpers": "npm:^7.25.7" + "@babel/parser": "npm:^7.25.7" + "@babel/template": "npm:^7.25.7" + "@babel/traverse": "npm:^7.25.7" + "@babel/types": "npm:^7.25.7" + convert-source-map: "npm:^2.0.0" + debug: "npm:^4.1.0" + gensync: "npm:^1.0.0-beta.2" + json5: "npm:^2.2.3" + semver: "npm:^6.3.1" + checksum: 10c0/dad20af39624086afc3a0910bd97ae712c9ad0e9dda09fc5da93876e8ea1802b63ddd81c44f4aa8a9834db46de801eaab1ce9b81ab54b4fe907ae052c24de136 + languageName: node + linkType: hard + "@babel/generator@npm:7.17.7": version: 7.17.7 resolution: "@babel/generator@npm:7.17.7" @@ -96,6 +136,18 @@ __metadata: languageName: node linkType: hard +"@babel/generator@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/generator@npm:7.25.7" + dependencies: + "@babel/types": "npm:^7.25.7" + "@jridgewell/gen-mapping": "npm:^0.3.5" + "@jridgewell/trace-mapping": "npm:^0.3.25" + jsesc: "npm:^3.0.2" + checksum: 10c0/c03a26c79864d60d04ce36b649c3fa0d6fd7b2bf6a22e22854a0457aa09206508392dd73ee40e7bc8d50b3602f9ff068afa47770cda091d332e7db1ca382ee96 + languageName: node + linkType: hard + "@babel/helper-annotate-as-pure@npm:^7.24.7": version: 7.24.7 resolution: "@babel/helper-annotate-as-pure@npm:7.24.7" @@ -118,6 +170,19 @@ __metadata: languageName: node linkType: hard +"@babel/helper-compilation-targets@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/helper-compilation-targets@npm:7.25.7" + dependencies: + "@babel/compat-data": "npm:^7.25.7" + "@babel/helper-validator-option": "npm:^7.25.7" + browserslist: "npm:^4.24.0" + lru-cache: "npm:^5.1.1" + semver: "npm:^6.3.1" + checksum: 10c0/705be7e5274a3fdade68e3e2cf42e2b600316ab52794e13b91299a16f16c926f15886b6e9d6df20eb943ccc1cdba5a363d4766f8d01e47b8e6f4e01175f5e66c + languageName: node + linkType: hard + "@babel/helper-environment-visitor@npm:^7.22.20": version: 7.24.7 resolution: "@babel/helper-environment-visitor@npm:7.24.7" @@ -156,6 +221,16 @@ __metadata: languageName: node linkType: hard +"@babel/helper-module-imports@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/helper-module-imports@npm:7.25.7" + dependencies: + "@babel/traverse": "npm:^7.25.7" + "@babel/types": "npm:^7.25.7" + checksum: 10c0/0fd0c3673835e5bf75558e184bcadc47c1f6dd2fe2016d53ebe1e5a6ae931a44e093015c2f9a6651c1a89f25c76d9246710c2b0b460b95ee069c464f2837fa2c + languageName: node + linkType: hard + "@babel/helper-module-transforms@npm:^7.25.2": version: 7.25.2 resolution: "@babel/helper-module-transforms@npm:7.25.2" @@ -170,6 +245,20 @@ __metadata: languageName: node linkType: hard +"@babel/helper-module-transforms@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/helper-module-transforms@npm:7.25.7" + dependencies: + "@babel/helper-module-imports": "npm:^7.25.7" + "@babel/helper-simple-access": "npm:^7.25.7" + "@babel/helper-validator-identifier": "npm:^7.25.7" + "@babel/traverse": "npm:^7.25.7" + peerDependencies: + "@babel/core": ^7.0.0 + checksum: 10c0/f37fa7d1d4df21690535b278468cbd5faf0133a3080f282000cfa4f3ffc9462a1458f866b04b6a2f2d1eec4691236cba9a867da61270dab3ab19846e62f05090 + languageName: node + linkType: hard + "@babel/helper-plugin-utils@npm:^7.24.7, @babel/helper-plugin-utils@npm:^7.24.8": version: 7.24.8 resolution: "@babel/helper-plugin-utils@npm:7.24.8" @@ -187,6 +276,16 @@ __metadata: languageName: node linkType: hard +"@babel/helper-simple-access@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/helper-simple-access@npm:7.25.7" + dependencies: + "@babel/traverse": "npm:^7.25.7" + "@babel/types": "npm:^7.25.7" + checksum: 10c0/eed1b499bfb4f613c18debd61517e3de77b6da2727ca025aa05ac81599e0269f1dddb5237db04e8bb598115d015874752e0a7f11ff38672d74a4976097417059 + languageName: node + linkType: hard + "@babel/helper-split-export-declaration@npm:^7.22.6": version: 7.24.7 resolution: "@babel/helper-split-export-declaration@npm:7.24.7" @@ -203,6 +302,13 @@ __metadata: languageName: node linkType: hard +"@babel/helper-string-parser@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/helper-string-parser@npm:7.25.7" + checksum: 10c0/73ef2ceb81f8294678a0afe8ab0103729c0370cac2e830e0d5128b03be5f6a2635838af31d391d763e3c5a4460ed96f42fd7c9b552130670d525be665913bc4c + languageName: node + linkType: hard + "@babel/helper-validator-identifier@npm:^7.16.7, @babel/helper-validator-identifier@npm:^7.24.7": version: 7.24.7 resolution: "@babel/helper-validator-identifier@npm:7.24.7" @@ -210,6 +316,13 @@ __metadata: languageName: node linkType: hard +"@babel/helper-validator-identifier@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/helper-validator-identifier@npm:7.25.7" + checksum: 10c0/07438e5bf01ab2882a15027fdf39ac3b0ba1b251774a5130917907014684e2f70fef8fd620137ca062c4c4eedc388508d2ea7a3a7d9936a32785f4fe116c68c0 + languageName: node + linkType: hard + "@babel/helper-validator-option@npm:^7.24.8": version: 7.24.8 resolution: "@babel/helper-validator-option@npm:7.24.8" @@ -217,6 +330,13 @@ __metadata: languageName: node linkType: hard +"@babel/helper-validator-option@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/helper-validator-option@npm:7.25.7" + checksum: 10c0/12ed418c8e3ed9ed44c8c80d823f4e42d399b5eb2e423adccb975e31a31a008cd3b5d8eab688b31f740caff4a1bb28fe06ea2fa7d635aee34cc0ad6995d50f0a + languageName: node + linkType: hard + "@babel/helpers@npm:^7.25.0": version: 7.25.6 resolution: "@babel/helpers@npm:7.25.6" @@ -227,6 +347,16 @@ __metadata: languageName: node linkType: hard +"@babel/helpers@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/helpers@npm:7.25.7" + dependencies: + "@babel/template": "npm:^7.25.7" + "@babel/types": "npm:^7.25.7" + checksum: 10c0/3b3ae9e373bd785414195ef8f59976a69d5a6ebe0ef2165fdcc5165e5c3ee09e0fcee94bb457df2ddb8c0532e4146d0a9b7a96b3497399a4bff4ffe196b30228 + languageName: node + linkType: hard + "@babel/highlight@npm:^7.24.7": version: 7.24.7 resolution: "@babel/highlight@npm:7.24.7" @@ -239,6 +369,18 @@ __metadata: languageName: node linkType: hard +"@babel/highlight@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/highlight@npm:7.25.7" + dependencies: + "@babel/helper-validator-identifier": "npm:^7.25.7" + chalk: "npm:^2.4.2" + js-tokens: "npm:^4.0.0" + picocolors: "npm:^1.0.0" + checksum: 10c0/1f5894fdb0a0af6101fb2822369b2eeeae32cbeae2ef73ff73fc6a0a4a20471565cd9cfa589f54ed69df66adeca7c57266031ca9134b7bd244d023a488d419aa + languageName: node + linkType: hard + "@babel/parser@npm:^7.20.5, @babel/parser@npm:^7.23.0, @babel/parser@npm:^7.25.0, @babel/parser@npm:^7.25.6": version: 7.25.6 resolution: "@babel/parser@npm:7.25.6" @@ -250,6 +392,17 @@ __metadata: languageName: node linkType: hard +"@babel/parser@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/parser@npm:7.25.7" + dependencies: + "@babel/types": "npm:^7.25.7" + bin: + parser: ./bin/babel-parser.js + checksum: 10c0/b771469bb6b636c18a8d642b9df3c73913c3860a979591e1a29a98659efd38b81d3e393047b5251fe382d4c82c681c12da9ce91c98d69316d2604d155a214bcf + languageName: node + linkType: hard + "@babel/plugin-syntax-jsx@npm:^7.24.7": version: 7.24.7 resolution: "@babel/plugin-syntax-jsx@npm:7.24.7" @@ -307,6 +460,17 @@ __metadata: languageName: node linkType: hard +"@babel/template@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/template@npm:7.25.7" + dependencies: + "@babel/code-frame": "npm:^7.25.7" + "@babel/parser": "npm:^7.25.7" + "@babel/types": "npm:^7.25.7" + checksum: 10c0/8ae9e36e4330ee83d4832531d1d9bec7dc2ef6a2a8afa1ef1229506fd60667abcb17f306d1c3d7e582251270597022990c845d5d69e7add70a5aea66720decb9 + languageName: node + linkType: hard + "@babel/traverse@npm:7.23.2": version: 7.23.2 resolution: "@babel/traverse@npm:7.23.2" @@ -340,6 +504,21 @@ __metadata: languageName: node linkType: hard +"@babel/traverse@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/traverse@npm:7.25.7" + dependencies: + "@babel/code-frame": "npm:^7.25.7" + "@babel/generator": "npm:^7.25.7" + "@babel/parser": "npm:^7.25.7" + "@babel/template": "npm:^7.25.7" + "@babel/types": "npm:^7.25.7" + debug: "npm:^4.3.1" + globals: "npm:^11.1.0" + checksum: 10c0/75d73e52c507a7a7a4c7971d6bf4f8f26fdd094e0d3a0193d77edf6a5efa36fc3db91ec5cc48e8b94e6eb5d5ad21af0a1040e71309172851209415fd105efb1a + languageName: node + linkType: hard + "@babel/types@npm:7.17.0": version: 7.17.0 resolution: "@babel/types@npm:7.17.0" @@ -361,6 +540,17 @@ __metadata: languageName: node linkType: hard +"@babel/types@npm:^7.25.7": + version: 7.25.7 + resolution: "@babel/types@npm:7.25.7" + dependencies: + "@babel/helper-string-parser": "npm:^7.25.7" + "@babel/helper-validator-identifier": "npm:^7.25.7" + to-fast-properties: "npm:^2.0.0" + checksum: 10c0/e03e1e2e08600fa1e8eb90632ac9c253dd748176c8d670d85f85b0dc83a0573b26ae748a1cbcb81f401903a3d95f43c3f4f8d516a5ed779929db27de56289633 + languageName: node + linkType: hard + "@emotion/babel-plugin@npm:^11.12.0": version: 11.12.0 resolution: "@emotion/babel-plugin@npm:11.12.0" @@ -728,10 +918,10 @@ __metadata: languageName: node linkType: hard -"@eslint/js@npm:9.11.1, @eslint/js@npm:^9.11.1": - version: 9.11.1 - resolution: "@eslint/js@npm:9.11.1" - checksum: 10c0/22916ef7b09c6f60c62635d897c66e1e3e38d90b5a5cf5e62769033472ecbcfb6ec7c886090a4b32fe65d6ce371da54384e46c26a899e38184dfc152c6152f7b +"@eslint/js@npm:9.12.0, @eslint/js@npm:^9.12.0": + version: 9.12.0 + resolution: "@eslint/js@npm:9.12.0" + checksum: 10c0/325650a59a1ce3d97c69441501ebaf415607248bacbe8c8ca35adc7cb73b524f592f266a75772f496b06f3239e3ee1996722a242148085f0ee5fb3dd7065897c languageName: node linkType: hard @@ -751,6 +941,23 @@ __metadata: languageName: node linkType: hard +"@humanfs/core@npm:^0.19.0": + version: 0.19.0 + resolution: "@humanfs/core@npm:0.19.0" + checksum: 10c0/f87952d5caba6ae427a620eff783c5d0b6cef0cfc256dec359cdaa636c5f161edb8d8dad576742b3de7f0b2f222b34aad6870248e4b7d2177f013426cbcda232 + languageName: node + linkType: hard + +"@humanfs/node@npm:^0.16.5": + version: 0.16.5 + resolution: "@humanfs/node@npm:0.16.5" + dependencies: + "@humanfs/core": "npm:^0.19.0" + "@humanwhocodes/retry": "npm:^0.3.0" + checksum: 10c0/41c365ab09e7c9eaeed373d09243195aef616d6745608a36fc3e44506148c28843872f85e69e2bf5f1e992e194286155a1c1cecfcece6a2f43875e37cd243935 + languageName: node + linkType: hard + "@humanwhocodes/module-importer@npm:^1.0.1": version: 1.0.1 resolution: "@humanwhocodes/module-importer@npm:1.0.1" @@ -765,6 +972,13 @@ __metadata: languageName: node linkType: hard +"@humanwhocodes/retry@npm:^0.3.1": + version: 0.3.1 + resolution: "@humanwhocodes/retry@npm:0.3.1" + checksum: 10c0/f0da1282dfb45e8120480b9e2e275e2ac9bbe1cf016d046fdad8e27cc1285c45bb9e711681237944445157b430093412b4446c1ab3fc4bb037861b5904101d3b + languageName: node + linkType: hard + "@isaacs/cliui@npm:^8.0.2": version: 8.0.2 resolution: "@isaacs/cliui@npm:8.0.2" @@ -831,38 +1045,38 @@ __metadata: languageName: node linkType: hard -"@mui/core-downloads-tracker@npm:^6.1.1": - version: 6.1.1 - resolution: "@mui/core-downloads-tracker@npm:6.1.1" - checksum: 10c0/ca837b75b8d2147a5a67785725b1158eff1240dbca65effbc9c4387fc7c342416bff332b0678378292738aa1b0224b866979c623a5da426904a43df394782286 +"@mui/core-downloads-tracker@npm:^6.1.2": + version: 6.1.2 + resolution: "@mui/core-downloads-tracker@npm:6.1.2" + checksum: 10c0/a685ac90a614be07c07bba752a6772be1caf06329e278c731f2a60b7712381c467adb3f5e0cfe7f2bc51b744ba76138f451853ff767c4739fa6379c8bc49d407 languageName: node linkType: hard -"@mui/icons-material@npm:^6.1.1": - version: 6.1.1 - resolution: "@mui/icons-material@npm:6.1.1" +"@mui/icons-material@npm:^6.1.2": + version: 6.1.2 + resolution: "@mui/icons-material@npm:6.1.2" dependencies: "@babel/runtime": "npm:^7.25.6" peerDependencies: - "@mui/material": ^6.1.1 + "@mui/material": ^6.1.2 "@types/react": ^17.0.0 || ^18.0.0 || ^19.0.0 react: ^17.0.0 || ^18.0.0 || ^19.0.0 peerDependenciesMeta: "@types/react": optional: true - checksum: 10c0/fc9f468ebf7ee9238606c915b648a4ba461d1ff241926131cd0de173d9092d8be6b2dc84a9d1bd8abcc6a349793e5501bd9d90487af7e946395a9b5ff104d498 + checksum: 10c0/ae5f1134e3ac45914c2bfef76a31848a8dc655237a9e478959580f778c31d77e6e54a588ec0ec552d8c6a904298f02d7cf482a5d6df294389d9ea9da8109ef94 languageName: node linkType: hard -"@mui/material@npm:^6.1.1": - version: 6.1.1 - resolution: "@mui/material@npm:6.1.1" +"@mui/material@npm:^6.1.2": + version: 6.1.2 + resolution: "@mui/material@npm:6.1.2" dependencies: "@babel/runtime": "npm:^7.25.6" - "@mui/core-downloads-tracker": "npm:^6.1.1" - "@mui/system": "npm:^6.1.1" + "@mui/core-downloads-tracker": "npm:^6.1.2" + "@mui/system": "npm:^6.1.2" "@mui/types": "npm:^7.2.17" - "@mui/utils": "npm:^6.1.1" + "@mui/utils": "npm:^6.1.2" "@popperjs/core": "npm:^2.11.8" "@types/react-transition-group": "npm:^4.4.11" clsx: "npm:^2.1.1" @@ -873,7 +1087,7 @@ __metadata: peerDependencies: "@emotion/react": ^11.5.0 "@emotion/styled": ^11.3.0 - "@mui/material-pigment-css": ^6.1.1 + "@mui/material-pigment-css": ^6.1.2 "@types/react": ^17.0.0 || ^18.0.0 || ^19.0.0 react: ^17.0.0 || ^18.0.0 || ^19.0.0 react-dom: ^17.0.0 || ^18.0.0 || ^19.0.0 @@ -886,16 +1100,16 @@ __metadata: optional: true "@types/react": optional: true - checksum: 10c0/ee47e8ac90db10e104fb3176512f5dd762e4cbf534d6377a0b515d738544eb56f3d4c8c54a1ddc029526b56443fc57ed3637164424245a1f3214d8ba4ff4b5eb + checksum: 10c0/7825be6ec47f82b3b3469fd0724b818bcc488f9b42de275fed38de314c216dfcefeec1cd23a0e8f8e6355ca51fbb2554ee4011834d6188a9245a8d60e7be2398 languageName: node linkType: hard -"@mui/private-theming@npm:^6.1.1": - version: 6.1.1 - resolution: "@mui/private-theming@npm:6.1.1" +"@mui/private-theming@npm:^6.1.2": + version: 6.1.2 + resolution: "@mui/private-theming@npm:6.1.2" dependencies: "@babel/runtime": "npm:^7.25.6" - "@mui/utils": "npm:^6.1.1" + "@mui/utils": "npm:^6.1.2" prop-types: "npm:^15.8.1" peerDependencies: "@types/react": ^17.0.0 || ^18.0.0 || ^19.0.0 @@ -903,13 +1117,13 @@ __metadata: peerDependenciesMeta: "@types/react": optional: true - checksum: 10c0/a4374cb55f6ca1959aa4cb38c28ace2d8e1e73f97cd0eb3c383a0de977df4a5e2966c5f0ab4d04c596ebf9c224aa196301162f3d1e72a43e20ae6cd06dadfc05 + checksum: 10c0/b8f8ee447dde7ecd34b9b96c19d68cff6771a7d5a133b85c3ff2dcb19fc8f2375375de6695c439dcfb6cb94e28d0a7c0889e132bfa467700a883e0dd834e8080 languageName: node linkType: hard -"@mui/styled-engine@npm:^6.1.1": - version: 6.1.1 - resolution: "@mui/styled-engine@npm:6.1.1" +"@mui/styled-engine@npm:^6.1.2": + version: 6.1.2 + resolution: "@mui/styled-engine@npm:6.1.2" dependencies: "@babel/runtime": "npm:^7.25.6" "@emotion/cache": "npm:^11.13.1" @@ -925,19 +1139,19 @@ __metadata: optional: true "@emotion/styled": optional: true - checksum: 10c0/5711ca945b9f93845df477da0a82107e8426d7e4a893d464ab968cbdfc6660960056c785c97a3752d1d6829c264bac78754b5585e4ab8a0e3e1738c505fa8770 + checksum: 10c0/cad5a768d039a8e6652c5f33371ff68e82afedec75f340a0c4154ca4bf29877f23e89c041b0cbdad7d81c4fe4e356882d0de3d24157a05323a88e9703ed85d30 languageName: node linkType: hard -"@mui/system@npm:^6.1.1": - version: 6.1.1 - resolution: "@mui/system@npm:6.1.1" +"@mui/system@npm:^6.1.2": + version: 6.1.2 + resolution: "@mui/system@npm:6.1.2" dependencies: "@babel/runtime": "npm:^7.25.6" - "@mui/private-theming": "npm:^6.1.1" - "@mui/styled-engine": "npm:^6.1.1" + "@mui/private-theming": "npm:^6.1.2" + "@mui/styled-engine": "npm:^6.1.2" "@mui/types": "npm:^7.2.17" - "@mui/utils": "npm:^6.1.1" + "@mui/utils": "npm:^6.1.2" clsx: "npm:^2.1.1" csstype: "npm:^3.1.3" prop-types: "npm:^15.8.1" @@ -953,7 +1167,7 @@ __metadata: optional: true "@types/react": optional: true - checksum: 10c0/9c7d63b369e4885066f23beac927dc5c8aad78bca32e66044744cb04320fdcd4fe2136de92135ae740b3ba8f369bcd3e75ca95fa7617d3021fd0d358b8aade9f + checksum: 10c0/b9240574f5db5a79d1ad1fc5dead2fc2b0dcaee2bc5515e6b8ea88cddd374f58adb18611fee65ae38ef165434712de425a6a5fc4d8d717d9b4f5a3716e2c3c46 languageName: node linkType: hard @@ -969,13 +1183,13 @@ __metadata: languageName: node linkType: hard -"@mui/utils@npm:^6.1.1": - version: 6.1.1 - resolution: "@mui/utils@npm:6.1.1" +"@mui/utils@npm:^6.1.2": + version: 6.1.2 + resolution: "@mui/utils@npm:6.1.2" dependencies: "@babel/runtime": "npm:^7.25.6" "@mui/types": "npm:^7.2.17" - "@types/prop-types": "npm:^15.7.12" + "@types/prop-types": "npm:^15.7.13" clsx: "npm:^2.1.1" prop-types: "npm:^15.8.1" react-is: "npm:^18.3.1" @@ -985,7 +1199,7 @@ __metadata: peerDependenciesMeta: "@types/react": optional: true - checksum: 10c0/4278d1810b6bf9cb366201414885cdcbfcee383030efc90444d5446a9bcc28ec5c5b299ca2a2b0280721f6d51116f29142119cc5c9c4ec86aafd9d5329aa01a6 + checksum: 10c0/ed56688610f3c04ad219066b5bd94b16c2c1318e2fc4d49e6d6d7b3800d10b4751185cbcc88431a3a1070a236f61e41238c06ef2998a3d65724ac6245a8b64e6 languageName: node linkType: hard @@ -1006,7 +1220,7 @@ __metadata: languageName: node linkType: hard -"@nodelib/fs.walk@npm:^1.2.3, @nodelib/fs.walk@npm:^1.2.8": +"@nodelib/fs.walk@npm:^1.2.3": version: 1.2.8 resolution: "@nodelib/fs.walk@npm:1.2.8" dependencies: @@ -1140,114 +1354,114 @@ __metadata: languageName: node linkType: hard -"@rollup/rollup-android-arm-eabi@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-android-arm-eabi@npm:4.22.4" +"@rollup/rollup-android-arm-eabi@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-android-arm-eabi@npm:4.23.0" conditions: os=android & cpu=arm languageName: node linkType: hard -"@rollup/rollup-android-arm64@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-android-arm64@npm:4.22.4" +"@rollup/rollup-android-arm64@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-android-arm64@npm:4.23.0" conditions: os=android & cpu=arm64 languageName: node linkType: hard -"@rollup/rollup-darwin-arm64@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-darwin-arm64@npm:4.22.4" +"@rollup/rollup-darwin-arm64@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-darwin-arm64@npm:4.23.0" conditions: os=darwin & cpu=arm64 languageName: node linkType: hard -"@rollup/rollup-darwin-x64@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-darwin-x64@npm:4.22.4" +"@rollup/rollup-darwin-x64@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-darwin-x64@npm:4.23.0" conditions: os=darwin & cpu=x64 languageName: node linkType: hard -"@rollup/rollup-linux-arm-gnueabihf@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-linux-arm-gnueabihf@npm:4.22.4" +"@rollup/rollup-linux-arm-gnueabihf@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-linux-arm-gnueabihf@npm:4.23.0" conditions: os=linux & cpu=arm & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-arm-musleabihf@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-linux-arm-musleabihf@npm:4.22.4" +"@rollup/rollup-linux-arm-musleabihf@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-linux-arm-musleabihf@npm:4.23.0" conditions: os=linux & cpu=arm & libc=musl languageName: node linkType: hard -"@rollup/rollup-linux-arm64-gnu@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-linux-arm64-gnu@npm:4.22.4" +"@rollup/rollup-linux-arm64-gnu@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-linux-arm64-gnu@npm:4.23.0" conditions: os=linux & cpu=arm64 & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-arm64-musl@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-linux-arm64-musl@npm:4.22.4" +"@rollup/rollup-linux-arm64-musl@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-linux-arm64-musl@npm:4.23.0" conditions: os=linux & cpu=arm64 & libc=musl languageName: node linkType: hard -"@rollup/rollup-linux-powerpc64le-gnu@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-linux-powerpc64le-gnu@npm:4.22.4" +"@rollup/rollup-linux-powerpc64le-gnu@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-linux-powerpc64le-gnu@npm:4.23.0" conditions: os=linux & cpu=ppc64 & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-riscv64-gnu@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-linux-riscv64-gnu@npm:4.22.4" +"@rollup/rollup-linux-riscv64-gnu@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-linux-riscv64-gnu@npm:4.23.0" conditions: os=linux & cpu=riscv64 & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-s390x-gnu@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-linux-s390x-gnu@npm:4.22.4" +"@rollup/rollup-linux-s390x-gnu@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-linux-s390x-gnu@npm:4.23.0" conditions: os=linux & cpu=s390x & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-x64-gnu@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-linux-x64-gnu@npm:4.22.4" +"@rollup/rollup-linux-x64-gnu@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-linux-x64-gnu@npm:4.23.0" conditions: os=linux & cpu=x64 & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-x64-musl@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-linux-x64-musl@npm:4.22.4" +"@rollup/rollup-linux-x64-musl@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-linux-x64-musl@npm:4.23.0" conditions: os=linux & cpu=x64 & libc=musl languageName: node linkType: hard -"@rollup/rollup-win32-arm64-msvc@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-win32-arm64-msvc@npm:4.22.4" +"@rollup/rollup-win32-arm64-msvc@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-win32-arm64-msvc@npm:4.23.0" conditions: os=win32 & cpu=arm64 languageName: node linkType: hard -"@rollup/rollup-win32-ia32-msvc@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-win32-ia32-msvc@npm:4.22.4" +"@rollup/rollup-win32-ia32-msvc@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-win32-ia32-msvc@npm:4.23.0" conditions: os=win32 & cpu=ia32 languageName: node linkType: hard -"@rollup/rollup-win32-x64-msvc@npm:4.22.4": - version: 4.22.4 - resolution: "@rollup/rollup-win32-x64-msvc@npm:4.22.4" +"@rollup/rollup-win32-x64-msvc@npm:4.23.0": + version: 4.23.0 + resolution: "@rollup/rollup-win32-x64-msvc@npm:4.23.0" conditions: os=win32 & cpu=x64 languageName: node linkType: hard @@ -1301,14 +1515,7 @@ __metadata: languageName: node linkType: hard -"@types/estree@npm:1.0.5": - version: 1.0.5 - resolution: "@types/estree@npm:1.0.5" - checksum: 10c0/b3b0e334288ddb407c7b3357ca67dbee75ee22db242ca7c56fe27db4e1a31989cb8af48a84dd401deb787fe10cc6b2ab1ee82dc4783be87ededbe3d53c79c70d - languageName: node - linkType: hard - -"@types/estree@npm:^1.0.6": +"@types/estree@npm:1.0.6, @types/estree@npm:^1.0.6": version: 1.0.6 resolution: "@types/estree@npm:1.0.6" checksum: 10c0/cdfd751f6f9065442cd40957c07fd80361c962869aa853c1c2fd03e101af8b9389d8ff4955a43a6fcfa223dd387a089937f95be0f3eec21ca527039fd2d9859a @@ -1437,16 +1644,7 @@ __metadata: languageName: node linkType: hard -"@types/node@npm:*": - version: 22.6.1 - resolution: "@types/node@npm:22.6.1" - dependencies: - undici-types: "npm:~6.19.2" - checksum: 10c0/79fdb14f268070eb21d25f3e81811b73c10dfcc65a638a6546fd97aa3e7dfe473f31a547fd21c43b8559a435b6ab26057066a47b5453bd1b1cdffe14430ac399 - languageName: node - linkType: hard - -"@types/node@npm:^22.7.4": +"@types/node@npm:*, @types/node@npm:^22.7.4": version: 22.7.4 resolution: "@types/node@npm:22.7.4" dependencies: @@ -1462,7 +1660,7 @@ __metadata: languageName: node linkType: hard -"@types/prop-types@npm:*, @types/prop-types@npm:^15.7.12": +"@types/prop-types@npm:*, @types/prop-types@npm:^15.7.13": version: 15.7.13 resolution: "@types/prop-types@npm:15.7.13" checksum: 10c0/1b20fc67281902c6743379960247bc161f3f0406ffc0df8e7058745a85ea1538612109db0406290512947f9632fe9e10e7337bf0ce6338a91d6c948df16a7c61 @@ -1509,22 +1707,22 @@ __metadata: linkType: hard "@types/react@npm:*": - version: 18.3.8 - resolution: "@types/react@npm:18.3.8" + version: 18.3.10 + resolution: "@types/react@npm:18.3.10" dependencies: "@types/prop-types": "npm:*" csstype: "npm:^3.0.2" - checksum: 10c0/367312c9fe276639ecb142265e090a4dd04bb39f8d718cbab546de3f1ddcfddeff415e1147d0fc40f734badaa7420b7b109d511bd4304b2c4c9c36164612fdf8 + checksum: 10c0/f5be1de1b0331c1fdb33d577f4cf7f1b949d4bded5347b2351a537f03c51dade5be115e21b161dcf1b37061954d320f6a0bdf8d7b70e24eda51071fdd614383d languageName: node linkType: hard -"@types/react@npm:^18.3.10": - version: 18.3.10 - resolution: "@types/react@npm:18.3.10" +"@types/react@npm:^18.3.11": + version: 18.3.11 + resolution: "@types/react@npm:18.3.11" dependencies: "@types/prop-types": "npm:*" csstype: "npm:^3.0.2" - checksum: 10c0/f5be1de1b0331c1fdb33d577f4cf7f1b949d4bded5347b2351a537f03c51dade5be115e21b161dcf1b37061954d320f6a0bdf8d7b70e24eda51071fdd614383d + checksum: 10c0/ce80512246ca5bda69db85b9f4f1835189334acfb6b2c4f3eda8cabff1ff1a3ea9ce4f3b895bdbc18c94140aa45592331aa3fdeb557f525c1b048de7ce84fc0e languageName: node linkType: hard @@ -1667,30 +1865,30 @@ __metadata: resolution: "EMS-ESP@workspace:." dependencies: "@alova/adapter-xhr": "npm:2.0.7" - "@babel/core": "npm:^7.25.2" + "@babel/core": "npm:^7.25.7" "@emotion/react": "npm:^11.13.3" "@emotion/styled": "npm:^11.13.0" - "@eslint/js": "npm:^9.11.1" - "@mui/icons-material": "npm:^6.1.1" - "@mui/material": "npm:^6.1.1" + "@eslint/js": "npm:^9.12.0" + "@mui/icons-material": "npm:^6.1.2" + "@mui/material": "npm:^6.1.2" "@preact/compat": "npm:^18.3.1" "@preact/preset-vite": "npm:^2.9.1" "@table-library/react-table-library": "npm:4.1.7" "@trivago/prettier-plugin-sort-imports": "npm:^4.3.0" "@types/formidable": "npm:^3" "@types/node": "npm:^22.7.4" - "@types/react": "npm:^18.3.10" + "@types/react": "npm:^18.3.11" "@types/react-dom": "npm:^18.3.0" "@types/react-router-dom": "npm:^5.3.3" alova: "npm:3.0.17" async-validator: "npm:^4.2.5" concurrently: "npm:^9.0.1" - eslint: "npm:^9.11.1" + eslint: "npm:^9.12.0" eslint-config-prettier: "npm:^9.1.0" formidable: "npm:^3.5.1" jwt-decode: "npm:^4.0.0" mime-types: "npm:^2.1.35" - preact: "npm:^10.24.1" + preact: "npm:^10.24.2" prettier: "npm:^3.3.3" react: "npm:^18.3.1" react-dom: "npm:^18.3.1" @@ -2015,17 +2213,17 @@ __metadata: languageName: node linkType: hard -"browserslist@npm:^4.23.1": - version: 4.23.3 - resolution: "browserslist@npm:4.23.3" +"browserslist@npm:^4.23.1, browserslist@npm:^4.24.0": + version: 4.24.0 + resolution: "browserslist@npm:4.24.0" dependencies: - caniuse-lite: "npm:^1.0.30001646" - electron-to-chromium: "npm:^1.5.4" + caniuse-lite: "npm:^1.0.30001663" + electron-to-chromium: "npm:^1.5.28" node-releases: "npm:^2.0.18" update-browserslist-db: "npm:^1.1.0" bin: browserslist: cli.js - checksum: 10c0/3063bfdf812815346447f4796c8f04601bf5d62003374305fd323c2a463e42776475bcc5309264e39bcf9a8605851e53560695991a623be988138b3ff8c66642 + checksum: 10c0/95e76ad522753c4c470427f6e3c8a4bb5478ff448841e22b3d3e53f89ecaf17b6984666d6c7e715c370f1e7fa0cf684f42e34e554236a8b2fab38ea76b9e4c52 languageName: node linkType: hard @@ -2136,10 +2334,10 @@ __metadata: languageName: node linkType: hard -"caniuse-lite@npm:^1.0.30001646": - version: 1.0.30001663 - resolution: "caniuse-lite@npm:1.0.30001663" - checksum: 10c0/6508e27bf7fdec657f26f318b1ab64ace6e1208ef9fedaf0975bc89046e0c683bfba837f108840ada1686ff09b8ffd01e05ac791dcf598b8f16eefb636875cf2 +"caniuse-lite@npm:^1.0.30001663": + version: 1.0.30001666 + resolution: "caniuse-lite@npm:1.0.30001666" + checksum: 10c0/2d49e9be676233c24717f12aad3d01b3e5f902b457fe1deefaa8d82e64786788a8f79381ae437c61b50e15c9aea8aeb59871b1d54cb4c28b9190d53d292e2339 languageName: node linkType: hard @@ -2746,10 +2944,10 @@ __metadata: languageName: node linkType: hard -"electron-to-chromium@npm:^1.5.4": - version: 1.5.28 - resolution: "electron-to-chromium@npm:1.5.28" - checksum: 10c0/6e2f4150ba03ce53ca128955c7d2da071d3774362a10c68848a85b71c29857915e2256cb53cd2de17fdbf0f56bf76ec174d24965abef7430d8c414ec733030b2 +"electron-to-chromium@npm:^1.5.28": + version: 1.5.31 + resolution: "electron-to-chromium@npm:1.5.31" + checksum: 10c0/e8aecd88c4c6d50a9d459b4b222865b855bab8f1b52e82913804e18b7884f2887bd76c61b3aa08c2ccbdcda098dd8486443f75bf770f0138f21dd9e63548fca7 languageName: node linkType: hard @@ -3116,7 +3314,7 @@ __metadata: languageName: node linkType: hard -"escalade@npm:^3.1.1, escalade@npm:^3.1.2": +"escalade@npm:^3.1.1, escalade@npm:^3.2.0": version: 3.2.0 resolution: "escalade@npm:3.2.0" checksum: 10c0/ced4dd3a78e15897ed3be74e635110bbf3b08877b0a41be50dcb325ee0e0b5f65fc2d50e9845194d7c4633f327e2e1c6cce00a71b617c5673df0374201d67f65 @@ -3148,13 +3346,13 @@ __metadata: languageName: node linkType: hard -"eslint-scope@npm:^8.0.2": - version: 8.0.2 - resolution: "eslint-scope@npm:8.0.2" +"eslint-scope@npm:^8.1.0": + version: 8.1.0 + resolution: "eslint-scope@npm:8.1.0" dependencies: esrecurse: "npm:^4.3.0" estraverse: "npm:^5.2.0" - checksum: 10c0/477f820647c8755229da913025b4567347fd1f0bf7cbdf3a256efff26a7e2e130433df052bd9e3d014025423dc00489bea47eb341002b15553673379c1a7dc36 + checksum: 10c0/ae1df7accae9ea90465c2ded70f7064d6d1f2962ef4cc87398855c4f0b3a5ab01063e0258d954bb94b184f6759febe04c3118195cab5c51978a7229948ba2875 languageName: node linkType: hard @@ -3165,27 +3363,27 @@ __metadata: languageName: node linkType: hard -"eslint-visitor-keys@npm:^4.0.0": - version: 4.0.0 - resolution: "eslint-visitor-keys@npm:4.0.0" - checksum: 10c0/76619f42cf162705a1515a6868e6fc7567e185c7063a05621a8ac4c3b850d022661262c21d9f1fc1d144ecf0d5d64d70a3f43c15c3fc969a61ace0fb25698cf5 +"eslint-visitor-keys@npm:^4.1.0": + version: 4.1.0 + resolution: "eslint-visitor-keys@npm:4.1.0" + checksum: 10c0/5483ef114c93a136aa234140d7aa3bd259488dae866d35cb0d0b52e6a158f614760a57256ac8d549acc590a87042cb40f6951815caa821e55dc4fd6ef4c722eb languageName: node linkType: hard -"eslint@npm:^9.11.1": - version: 9.11.1 - resolution: "eslint@npm:9.11.1" +"eslint@npm:^9.12.0": + version: 9.12.0 + resolution: "eslint@npm:9.12.0" dependencies: "@eslint-community/eslint-utils": "npm:^4.2.0" "@eslint-community/regexpp": "npm:^4.11.0" "@eslint/config-array": "npm:^0.18.0" "@eslint/core": "npm:^0.6.0" "@eslint/eslintrc": "npm:^3.1.0" - "@eslint/js": "npm:9.11.1" + "@eslint/js": "npm:9.12.0" "@eslint/plugin-kit": "npm:^0.2.0" + "@humanfs/node": "npm:^0.16.5" "@humanwhocodes/module-importer": "npm:^1.0.1" - "@humanwhocodes/retry": "npm:^0.3.0" - "@nodelib/fs.walk": "npm:^1.2.8" + "@humanwhocodes/retry": "npm:^0.3.1" "@types/estree": "npm:^1.0.6" "@types/json-schema": "npm:^7.0.15" ajv: "npm:^6.12.4" @@ -3193,9 +3391,9 @@ __metadata: cross-spawn: "npm:^7.0.2" debug: "npm:^4.3.2" escape-string-regexp: "npm:^4.0.0" - eslint-scope: "npm:^8.0.2" - eslint-visitor-keys: "npm:^4.0.0" - espree: "npm:^10.1.0" + eslint-scope: "npm:^8.1.0" + eslint-visitor-keys: "npm:^4.1.0" + espree: "npm:^10.2.0" esquery: "npm:^1.5.0" esutils: "npm:^2.0.2" fast-deep-equal: "npm:^3.1.3" @@ -3205,13 +3403,11 @@ __metadata: ignore: "npm:^5.2.0" imurmurhash: "npm:^0.1.4" is-glob: "npm:^4.0.0" - is-path-inside: "npm:^3.0.3" json-stable-stringify-without-jsonify: "npm:^1.0.1" lodash.merge: "npm:^4.6.2" minimatch: "npm:^3.1.2" natural-compare: "npm:^1.4.0" optionator: "npm:^0.9.3" - strip-ansi: "npm:^6.0.1" text-table: "npm:^0.2.0" peerDependencies: jiti: "*" @@ -3220,18 +3416,18 @@ __metadata: optional: true bin: eslint: bin/eslint.js - checksum: 10c0/fc9afc31155fef8c27fc4fd00669aeafa4b89ce5abfbf6f60e05482c03d7ff1d5e7546e416aa47bf0f28c9a56597a94663fd0264c2c42a1890f53cac49189f24 + checksum: 10c0/67cf6ea3ea28dcda7dd54aac33e2d4028eb36991d13defb0d2339c3eaa877d5dddd12cd4416ddc701a68bcde9e0bb9e65524c2e4e9914992c724f5b51e949dda languageName: node linkType: hard -"espree@npm:^10.0.1, espree@npm:^10.1.0": - version: 10.1.0 - resolution: "espree@npm:10.1.0" +"espree@npm:^10.0.1, espree@npm:^10.2.0": + version: 10.2.0 + resolution: "espree@npm:10.2.0" dependencies: acorn: "npm:^8.12.0" acorn-jsx: "npm:^5.3.2" - eslint-visitor-keys: "npm:^4.0.0" - checksum: 10c0/52e6feaa77a31a6038f0c0e3fce93010a4625701925b0715cd54a2ae190b3275053a0717db698697b32653788ac04845e489d6773b508d6c2e8752f3c57470a0 + eslint-visitor-keys: "npm:^4.1.0" + checksum: 10c0/2b6bfb683e7e5ab2e9513949879140898d80a2d9867ea1db6ff5b0256df81722633b60a7523a7c614f05a39aeea159dd09ad2a0e90c0e218732fc016f9086215 languageName: node linkType: hard @@ -4378,13 +4574,6 @@ __metadata: languageName: node linkType: hard -"is-path-inside@npm:^3.0.3": - version: 3.0.3 - resolution: "is-path-inside@npm:3.0.3" - checksum: 10c0/cf7d4ac35fb96bab6a1d2c3598fe5ebb29aafb52c0aaa482b5a3ed9d8ba3edc11631e3ec2637660c44b3ce0e61a08d54946e8af30dec0b60a7c27296c68ffd05 - languageName: node - linkType: hard - "is-plain-obj@npm:^1.0.0, is-plain-obj@npm:^1.1.0": version: 1.1.0 resolution: "is-plain-obj@npm:1.1.0" @@ -4555,6 +4744,15 @@ __metadata: languageName: node linkType: hard +"jsesc@npm:^3.0.2": + version: 3.0.2 + resolution: "jsesc@npm:3.0.2" + bin: + jsesc: bin/jsesc + checksum: 10c0/ef22148f9e793180b14d8a145ee6f9f60f301abf443288117b4b6c53d0ecd58354898dc506ccbb553a5f7827965cd38bc5fb726575aae93c5e8915e2de8290e1 + languageName: node + linkType: hard + "json-buffer@npm:3.0.0": version: 3.0.0 resolution: "json-buffer@npm:3.0.0" @@ -5413,9 +5611,9 @@ __metadata: linkType: hard "package-json-from-dist@npm:^1.0.0": - version: 1.0.0 - resolution: "package-json-from-dist@npm:1.0.0" - checksum: 10c0/e3ffaf6ac1040ab6082a658230c041ad14e72fabe99076a2081bb1d5d41210f11872403fc09082daf4387fc0baa6577f96c9c0e94c90c394fd57794b66aa4033 + version: 1.0.1 + resolution: "package-json-from-dist@npm:1.0.1" + checksum: 10c0/62ba2785eb655fec084a257af34dbe24292ab74516d6aecef97ef72d4897310bc6898f6c85b5cd22770eaa1ce60d55a0230e150fb6a966e3ecd6c511e23d164b languageName: node linkType: hard @@ -5535,7 +5733,7 @@ __metadata: languageName: node linkType: hard -"picocolors@npm:^1.0.0, picocolors@npm:^1.0.1, picocolors@npm:^1.1.0": +"picocolors@npm:^1.0.0, picocolors@npm:^1.1.0": version: 1.1.0 resolution: "picocolors@npm:1.1.0" checksum: 10c0/86946f6032148801ef09c051c6fb13b5cf942eaf147e30ea79edb91dd32d700934edebe782a1078ff859fb2b816792e97ef4dab03d7f0b804f6b01a0df35e023 @@ -5610,10 +5808,10 @@ __metadata: languageName: node linkType: hard -"preact@npm:^10.24.1": - version: 10.24.1 - resolution: "preact@npm:10.24.1" - checksum: 10c0/f9bc8b2f88d340f1b8f854208889244059c46916449b8f8f2174fcacbc0904c445c5870896fb0cfeaf442eeade975857e8e03f0785135c41d63cd32d9414c9c6 +"preact@npm:^10.24.2": + version: 10.24.2 + resolution: "preact@npm:10.24.2" + checksum: 10c0/d1d22c5e1abc10eb8f83501857ef22c54a3fda2d20449d06f5b3c7d5ae812bd702c16c05b672138b8906504f9c893e072e9cebcbcada8cac320edf36265788fb languageName: node linkType: hard @@ -6019,26 +6217,26 @@ __metadata: linkType: hard "rollup@npm:^4.20.0": - version: 4.22.4 - resolution: "rollup@npm:4.22.4" - dependencies: - "@rollup/rollup-android-arm-eabi": "npm:4.22.4" - "@rollup/rollup-android-arm64": "npm:4.22.4" - "@rollup/rollup-darwin-arm64": "npm:4.22.4" - "@rollup/rollup-darwin-x64": "npm:4.22.4" - "@rollup/rollup-linux-arm-gnueabihf": "npm:4.22.4" - "@rollup/rollup-linux-arm-musleabihf": "npm:4.22.4" - "@rollup/rollup-linux-arm64-gnu": "npm:4.22.4" - "@rollup/rollup-linux-arm64-musl": "npm:4.22.4" - "@rollup/rollup-linux-powerpc64le-gnu": "npm:4.22.4" - "@rollup/rollup-linux-riscv64-gnu": "npm:4.22.4" - "@rollup/rollup-linux-s390x-gnu": "npm:4.22.4" - "@rollup/rollup-linux-x64-gnu": "npm:4.22.4" - "@rollup/rollup-linux-x64-musl": "npm:4.22.4" - "@rollup/rollup-win32-arm64-msvc": "npm:4.22.4" - "@rollup/rollup-win32-ia32-msvc": "npm:4.22.4" - "@rollup/rollup-win32-x64-msvc": "npm:4.22.4" - "@types/estree": "npm:1.0.5" + version: 4.23.0 + resolution: "rollup@npm:4.23.0" + dependencies: + "@rollup/rollup-android-arm-eabi": "npm:4.23.0" + "@rollup/rollup-android-arm64": "npm:4.23.0" + "@rollup/rollup-darwin-arm64": "npm:4.23.0" + "@rollup/rollup-darwin-x64": "npm:4.23.0" + "@rollup/rollup-linux-arm-gnueabihf": "npm:4.23.0" + "@rollup/rollup-linux-arm-musleabihf": "npm:4.23.0" + "@rollup/rollup-linux-arm64-gnu": "npm:4.23.0" + "@rollup/rollup-linux-arm64-musl": "npm:4.23.0" + "@rollup/rollup-linux-powerpc64le-gnu": "npm:4.23.0" + "@rollup/rollup-linux-riscv64-gnu": "npm:4.23.0" + "@rollup/rollup-linux-s390x-gnu": "npm:4.23.0" + "@rollup/rollup-linux-x64-gnu": "npm:4.23.0" + "@rollup/rollup-linux-x64-musl": "npm:4.23.0" + "@rollup/rollup-win32-arm64-msvc": "npm:4.23.0" + "@rollup/rollup-win32-ia32-msvc": "npm:4.23.0" + "@rollup/rollup-win32-x64-msvc": "npm:4.23.0" + "@types/estree": "npm:1.0.6" fsevents: "npm:~2.3.2" dependenciesMeta: "@rollup/rollup-android-arm-eabi": @@ -6077,7 +6275,7 @@ __metadata: optional: true bin: rollup: dist/bin/rollup - checksum: 10c0/4c96b6e2e0c5dbe73b4ba899cea894a05115ab8c65ccff631fbbb944e2b3a9f2eb3b99c2dce3dd91b179647df1892ffc44ecee29381ccf155ba8000b22712a32 + checksum: 10c0/bae754b79f157c8ae6f63f2ca72adb1ea4ccc7734f5ff349d6231d4cab200605246883226b2c04592a77844aa369abd85fa63788602c916bb475cf887c8a1a49 languageName: node linkType: hard @@ -6880,16 +7078,16 @@ __metadata: linkType: hard "update-browserslist-db@npm:^1.1.0": - version: 1.1.0 - resolution: "update-browserslist-db@npm:1.1.0" + version: 1.1.1 + resolution: "update-browserslist-db@npm:1.1.1" dependencies: - escalade: "npm:^3.1.2" - picocolors: "npm:^1.0.1" + escalade: "npm:^3.2.0" + picocolors: "npm:^1.1.0" peerDependencies: browserslist: ">= 4.21.0" bin: update-browserslist-db: cli.js - checksum: 10c0/a7452de47785842736fb71547651c5bbe5b4dc1e3722ccf48a704b7b34e4dcf633991eaa8e4a6a517ffb738b3252eede3773bef673ef9021baa26b056d63a5b9 + checksum: 10c0/536a2979adda2b4be81b07e311bd2f3ad5e978690987956bc5f514130ad50cac87cd22c710b686d79731e00fbee8ef43efe5fcd72baa241045209195d43dcc80 languageName: node linkType: hard diff --git a/mock-api/mockServer.js b/mock-api/mockServer.js index 395874a30..9c82c49ba 100644 --- a/mock-api/mockServer.js +++ b/mock-api/mockServer.js @@ -4,7 +4,7 @@ import formidable from 'formidable'; function pad(number) { - var r = String(number); + let r = String(number); if (r.length === 1) { r = '0' + r; } diff --git a/src/console.cpp b/src/console.cpp index bd7aff5e0..f12a61464 100644 --- a/src/console.cpp +++ b/src/console.cpp @@ -39,10 +39,6 @@ static inline EMSESPShell & to_shell(Shell & shell) { return static_cast(shell); } -static inline EMSESP & to_app(Shell & shell) { - return to_shell(shell).emsesp_; -} - #define NO_ARGUMENTS \ std::vector { \ } @@ -67,7 +63,7 @@ static std::vector log_level_autocomplete(Shell & shell, const std: return uuid::log::levels_lowercase(); } -static void setup_commands(std::shared_ptr & commands) { +static void setup_commands(std::shared_ptr const & commands) { // exit, help, log commands->add_command(ShellContext::MAIN, CommandFlags::USER, {F_(exit)}, EMSESPShell::main_exit_function); commands->add_command(ShellContext::MAIN, CommandFlags::USER, {F_(help)}, EMSESPShell::main_help_function); @@ -81,35 +77,35 @@ static void setup_commands(std::shared_ptr & commands) { CommandFlags::USER, {F_(show)}, {F_(show_commands)}, - [=](Shell & shell, const std::vector & arguments) { + [](Shell & shell, const std::vector & arguments) { if (arguments.empty()) { - to_app(shell).system_.show_system(shell); + EMSESP::system_.show_system(shell); return; } - auto command = arguments.front(); + auto const & command = arguments.front(); if (command == F_(commands)) { Command::show_all(shell); } else if (command == F_(system)) { - to_app(shell).system_.show_system(shell); + EMSESP::system_.show_system(shell); } else if (command == F_(users) && (shell.has_flags(CommandFlags::ADMIN))) { - to_app(shell).system_.show_users(shell); // admin only + EMSESP::system_.show_users(shell); // admin only } else if (command == F_(devices)) { - to_app(shell).show_devices(shell); + EMSESP::show_devices(shell); } else if (command == F_(log)) { - to_app(shell).webLogService.show(shell); + EMSESP::webLogService.show(shell); } else if (command == F_(ems)) { - to_app(shell).show_ems(shell); + EMSESP::show_ems(shell); } else if (command == F_(values)) { - to_app(shell).show_device_values(shell); - to_app(shell).show_sensor_values(shell); + EMSESP::show_device_values(shell); + EMSESP::show_sensor_values(shell); } else if (command == F_(mqtt)) { Mqtt::show_mqtt(shell); } else { shell.printfln("Unknown show command"); } }, - [](Shell & shell, const std::vector & current_arguments, const std::string & next_argument) -> std::vector { + [](Shell const & shell, const std::vector & current_arguments, const std::string & next_argument) -> std::vector { return std::vector{"system", "users", "devices", "log", "ems", "values", "mqtt", "commands"}; }); @@ -154,7 +150,7 @@ static void setup_commands(std::shared_ptr & commands) { if (completed) { uint64_t now = uuid::get_uptime_ms(); - to_app(shell).esp8266React.getSecuritySettingsService()->read([&](SecuritySettings & securitySettings) { + EMSESP::esp8266React.getSecuritySettingsService()->read([&](SecuritySettings & securitySettings) { if (!password.empty() && (securitySettings.jwtSecret.equals(password.c_str()))) { become_admin(shell); } else { @@ -178,7 +174,7 @@ static void setup_commands(std::shared_ptr & commands) { shell.enter_password(F_(new_password_prompt2), [password1](Shell & shell, bool completed, const std::string & password2) { if (completed) { if (password1 == password2) { - to_app(shell).esp8266React.getSecuritySettingsService()->update([&](SecuritySettings & securitySettings) { + EMSESP::esp8266React.getSecuritySettingsService()->update([&](SecuritySettings & securitySettings) { securitySettings.jwtSecret = password2.c_str(); return StateUpdateResult::CHANGED; }); @@ -198,16 +194,16 @@ static void setup_commands(std::shared_ptr & commands) { {F_(partitionname_optional)}, [](Shell & shell, const std::vector & arguments) { if (arguments.size()) { - to_app(shell).system_.system_restart(arguments.front().c_str()); + EMSESP::system_.system_restart(arguments.front().c_str()); } else { - to_app(shell).system_.system_restart(); + EMSESP::system_.system_restart(); } }); commands->add_command(ShellContext::MAIN, CommandFlags::ADMIN, string_vector{F_(wifi), F_(reconnect)}, - [](Shell & shell, const std::vector & arguments) { to_app(shell).system_.wifi_reconnect(); }); + [](Shell & shell, const std::vector & arguments) { EMSESP::system_.wifi_reconnect(); }); // // SET commands @@ -221,13 +217,13 @@ static void setup_commands(std::shared_ptr & commands) { shell.enter_password(F_(new_password_prompt2), [password1](Shell & shell, bool completed, const std::string & password2) { if (completed) { if (password1 == password2) { - to_app(shell).esp8266React.getNetworkSettingsService()->updateWithoutPropagation( + EMSESP::esp8266React.getNetworkSettingsService()->updateWithoutPropagation( [&](NetworkSettings & networkSettings) { networkSettings.password = password2.c_str(); return StateUpdateResult::CHANGED; }); shell.println("WiFi password updated. Reconnecting..."); - to_app(shell).system_.wifi_reconnect(); + EMSESP::system_.wifi_reconnect(); } else { shell.println("Passwords do not match"); } @@ -245,7 +241,7 @@ static void setup_commands(std::shared_ptr & commands) { shell.println("The network connection will be reset..."); Shell::loop_all(); delay(1000); // wait a second - to_app(shell).esp8266React.getNetworkSettingsService()->update([&](NetworkSettings & networkSettings) { + EMSESP::esp8266React.getNetworkSettingsService()->update([&](NetworkSettings & networkSettings) { networkSettings.hostname = arguments.front().c_str(); return StateUpdateResult::CHANGED; }); @@ -256,12 +252,12 @@ static void setup_commands(std::shared_ptr & commands) { string_vector{F_(set), F_(wifi), F_(ssid)}, {F_(name_mandatory)}, [](Shell & shell, const std::vector & arguments) { - to_app(shell).esp8266React.getNetworkSettingsService()->updateWithoutPropagation([&](NetworkSettings & networkSettings) { + EMSESP::esp8266React.getNetworkSettingsService()->updateWithoutPropagation([&](NetworkSettings & networkSettings) { networkSettings.ssid = arguments.front().c_str(); return StateUpdateResult::CHANGED; }); shell.println("WiFi ssid updated. Reconnecting..."); - to_app(shell).system_.wifi_reconnect(); + EMSESP::system_.wifi_reconnect(); }); @@ -273,12 +269,12 @@ static void setup_commands(std::shared_ptr & commands) { [](Shell & shell, const std::vector & arguments) { std::vector data; // led, dallas, rx, tx, button, phy_type, eth_power, eth_phy_addr, eth_clock_mode std::string board_profile = Helpers::toUpper(arguments.front()); - if (!to_app(shell).system_.load_board_profile(data, board_profile)) { + if (!EMSESP::system_.load_board_profile(data, board_profile)) { shell.println("Invalid board profile (S32, E32, E32V2, MH-ET, NODEMCU, LOLIN, OLIMEX, OLIMEXPOE, C3MINI, S2MINI, S3MINI, S32S3, CUSTOM)"); return; } - to_app(shell).webSettingsService.update([&](WebSettings & settings) { + EMSESP::webSettingsService.update([&](WebSettings & settings) { settings.board_profile = board_profile.c_str(); settings.led_gpio = data[0]; settings.dallas_gpio = data[1]; @@ -292,7 +288,7 @@ static void setup_commands(std::shared_ptr & commands) { return StateUpdateResult::CHANGED; }); shell.printfln("Loaded board profile %s", board_profile.c_str()); - to_app(shell).system_.network_init(true); + EMSESP::system_.network_init(true); }); commands->add_command( @@ -303,7 +299,7 @@ static void setup_commands(std::shared_ptr & commands) { [](Shell & shell, const std::vector & arguments) { uint8_t device_id = Helpers::hextoint(arguments.front().c_str()); if ((device_id == 0x0B) || (device_id == 0x0D) || (device_id == 0x0A) || (device_id == 0x0F) || (device_id == 0x12)) { - to_app(shell).webSettingsService.update([&](WebSettings & settings) { + EMSESP::webSettingsService.update([&](WebSettings & settings) { settings.ems_bus_id = device_id; shell.printfln(F_(bus_id_fmt), settings.ems_bus_id); return StateUpdateResult::CHANGED; @@ -323,12 +319,12 @@ static void setup_commands(std::shared_ptr & commands) { [](Shell & shell, const std::vector & arguments) { uint8_t tx_mode = std::strtol(arguments[0].c_str(), nullptr, 10); // save the tx_mode - to_app(shell).webSettingsService.update([&](WebSettings & settings) { + EMSESP::webSettingsService.update([&](WebSettings & settings) { settings.tx_mode = tx_mode; shell.printfln(F_(tx_mode_fmt), settings.tx_mode); return StateUpdateResult::CHANGED; }); - to_app(shell).uart_init(); + EMSESP::uart_init(); }); commands->add_command(ShellContext::MAIN, @@ -339,17 +335,17 @@ static void setup_commands(std::shared_ptr & commands) { if (arguments.back() == "enable" || arguments.back() == "disable") { bool enable = arguments.back() == "enable"; if (arguments.front() == "mqtt") { - to_app(shell).esp8266React.getMqttSettingsService()->update([&](MqttSettings & Settings) { + EMSESP::esp8266React.getMqttSettingsService()->update([&](MqttSettings & Settings) { Settings.enabled = enable; return StateUpdateResult::CHANGED; }); } else if (arguments.front() == "ntp") { - to_app(shell).esp8266React.getNTPSettingsService()->update([&](NTPSettings & Settings) { + EMSESP::esp8266React.getNTPSettingsService()->update([&](NTPSettings & Settings) { Settings.enabled = enable; return StateUpdateResult::CHANGED; }); } else if (arguments.front() == "ap") { - to_app(shell).esp8266React.getAPSettingsService()->update([&](APSettings & Settings) { + EMSESP::esp8266React.getAPSettingsService()->update([&](APSettings & Settings) { Settings.provisionMode = enable ? 0 : 2; return StateUpdateResult::CHANGED; }); @@ -368,17 +364,17 @@ static void setup_commands(std::shared_ptr & commands) { // commands->add_command(ShellContext::MAIN, CommandFlags::ADMIN, {F_(scan)}, {F_(deep_optional)}, [](Shell & shell, const std::vector & arguments) { - if (arguments.size() == 0) { - to_app(shell).scan_devices(); + if (arguments.empty()) { + EMSESP::scan_devices(); } else { shell.printfln("Performing a deep scan..."); - to_app(shell).clear_all_devices(); + EMSESP::clear_all_devices(); // device IDs taken from device_library.h // send the read command with Version command const std::vector Device_Ids = {0x02, 0x08, 0x09, 0x10, 0x11, 0x12, 0x15, 0x17, 0x18, 0x19, 0x1A, 0x1B, 0x20, 0x21, 0x22, 0x23, 0x24, 0x25, 0x26, 0x27, 0x28, 0x29, 0x2A, 0x30, 0x38, 0x40, 0x41, 0x48, 0x50, 0x51, 0x60}; for (const uint8_t device_id : Device_Ids) { - to_app(shell).send_read_request(EMSdevice::EMS_TYPE_VERSION, device_id); + EMSESP::send_read_request(EMSdevice::EMS_TYPE_VERSION, device_id); } } }); @@ -390,7 +386,7 @@ static void setup_commands(std::shared_ptr & commands) { [=](Shell & shell, const std::vector & arguments) { uint8_t device_id = Helpers::hextoint(arguments.front().c_str()); - if (!to_app(shell).valid_device(device_id)) { + if (!EMSESP::valid_device(device_id)) { shell.printfln("Invalid deviceID"); return; } @@ -399,14 +395,14 @@ static void setup_commands(std::shared_ptr & commands) { if (arguments.size() == 4) { uint16_t offset = Helpers::hextoint(arguments[2].c_str()); uint8_t length = Helpers::hextoint(arguments.back().c_str()); - to_app(shell).send_read_request(type_id, device_id, offset, length, true); + EMSESP::send_read_request(type_id, device_id, offset, length, true); } else if (arguments.size() == 3) { uint16_t offset = Helpers::hextoint(arguments.back().c_str()); - to_app(shell).send_read_request(type_id, device_id, offset, 0, true); + EMSESP::send_read_request(type_id, device_id, offset, 0, true); } else { - to_app(shell).send_read_request(type_id, device_id, 0, 0, true); + EMSESP::send_read_request(type_id, device_id, 0, 0, true); } - to_app(shell).set_read_id(type_id); + EMSESP::set_read_id(type_id); }); commands->add_command(ShellContext::MAIN, @@ -419,22 +415,21 @@ static void setup_commands(std::shared_ptr & commands) { // only use english commands, not the translations if (!arguments.empty()) { // get raw/pretty - if (arguments[0] == (F_(raw))) { - to_app(shell).watch(to_app(shell).WATCH_RAW); // raw + if (arguments[0] == F_(raw)) { + EMSESP::watch(EMSESP::WATCH_RAW); // raw } else if (arguments[0] == (FL_(on)[0])) { - to_app(shell).watch(to_app(shell).WATCH_ON); // on + EMSESP::watch(EMSESP::WATCH_ON); // on } else if (arguments[0] == (FL_(off)[0])) { - to_app(shell).watch(to_app(shell).WATCH_OFF); // off + EMSESP::watch(EMSESP::WATCH_OFF); // off } else if (arguments[0] == (FL_(unknown)[0])) { - to_app(shell).watch(to_app(shell).WATCH_UNKNOWN); // unknown + EMSESP::watch(EMSESP::WATCH_UNKNOWN); // unknown watch_id = WATCH_ID_NONE; } else { watch_id = Helpers::hextoint(arguments[0].c_str()); - if (watch_id > 0 - && ((to_app(shell).watch() == to_app(shell).WATCH_OFF) || (to_app(shell).watch() == to_app(shell).WATCH_UNKNOWN))) { - to_app(shell).watch(to_app(shell).WATCH_ON); // on + if (watch_id > 0 && ((EMSESP::watch() == EMSESP::WATCH_OFF) || (EMSESP::watch() == EMSESP::WATCH_UNKNOWN))) { + EMSESP::watch(EMSESP::WATCH_ON); // on } else if (watch_id == 0) { - to_app(shell).watch(to_app(shell).WATCH_OFF); // off + EMSESP::watch(EMSESP::WATCH_OFF); // off return; } } @@ -444,14 +439,14 @@ static void setup_commands(std::shared_ptr & commands) { watch_id = Helpers::hextoint(arguments[1].c_str()); } - to_app(shell).watch_id(watch_id); + EMSESP::watch_id(watch_id); } else { shell.printfln("Invalid: use watch raw|on|off|unknown|id [id]"); return; } - uint8_t watch = to_app(shell).watch(); - if (watch == to_app(shell).WATCH_OFF) { + uint8_t watch = EMSESP::watch(); + if (watch == EMSESP::WATCH_OFF) { shell.printfln("Watching telegrams is off"); return; } @@ -462,15 +457,15 @@ static void setup_commands(std::shared_ptr & commands) { shell.printfln("Setting log level to Notice"); } - if (watch == to_app(shell).WATCH_ON) { + if (watch == EMSESP::WATCH_ON) { shell.printfln("Watching incoming telegrams, displayed in decoded format"); - } else if (watch == to_app(shell).WATCH_RAW) { + } else if (watch == EMSESP::WATCH_RAW) { shell.printfln("Watching incoming telegrams, displayed as raw bytes"); // WATCH_RAW } else { shell.printfln("Watching unknown telegrams"); // WATCH_UNKNOWN } - watch_id = to_app(shell).watch_id(); + watch_id = EMSESP::watch_id(); if (watch_id > 0x80) { shell.printfln("Filtering only telegrams that match a telegram type of 0x%02X", watch_id); } else if (watch_id != WATCH_ID_NONE) { @@ -571,7 +566,7 @@ static void setup_commands(std::shared_ptr & commands) { } }, [](Shell & shell, const std::vector & current_arguments, const std::string & next_argument) -> std::vector { - if (current_arguments.size() == 0) { + if (current_arguments.empty()) { std::vector devices_list; devices_list.emplace_back(EMSdevice::device_type_2_device_name(EMSdevice::DeviceType::SYSTEM)); devices_list.emplace_back(EMSdevice::device_type_2_device_name(EMSdevice::DeviceType::TEMPERATURESENSOR)); @@ -600,7 +595,7 @@ static void setup_commands(std::shared_ptr & commands) { } std::shared_ptr EMSESPShell::commands_ = [] { - std::shared_ptr commands = std::make_shared(); + auto commands = std::make_shared(); setup_commands(commands); return commands; }(); diff --git a/src/device_library.h b/src/device_library.h index cb48b1f27..6a915c201 100644 --- a/src/device_library.h +++ b/src/device_library.h @@ -24,40 +24,40 @@ */ // Boilers - 0x08 -{ 8, DeviceType::BOILER, "CS5800i/CS6800i/WLW176i", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP}, +{ 8, DeviceType::BOILER, "CS*800i, Logatherm WLW*", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP}, { 12, DeviceType::BOILER, "C1200W", DeviceFlags::EMS_DEVICE_FLAG_NONE}, -{ 64, DeviceType::BOILER, "BK13/BK15/Smartline/GB1x2", DeviceFlags::EMS_DEVICE_FLAG_NONE}, -{ 72, DeviceType::BOILER, "GB125/GB135/MC10", DeviceFlags::EMS_DEVICE_FLAG_EMS}, +{ 64, DeviceType::BOILER, "BK13/BK15, Smartline, GB1*2", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{ 72, DeviceType::BOILER, "Logano GB1*5, Logamatic MC10", DeviceFlags::EMS_DEVICE_FLAG_EMS}, { 81, DeviceType::BOILER, "Cascade CM10", DeviceFlags::EMS_DEVICE_FLAG_NONE}, { 84, DeviceType::BOILER, "Logamax Plus GB022", DeviceFlags::EMS_DEVICE_FLAG_NONE}, -{ 95, DeviceType::BOILER, "Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3", DeviceFlags::EMS_DEVICE_FLAG_HT3}, -{115, DeviceType::BOILER, "Topline/GB162", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{ 95, DeviceType::BOILER, "Condens 2500/5000W, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3", DeviceFlags::EMS_DEVICE_FLAG_HT3}, +{115, DeviceType::BOILER, "Topline, GB162", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {121, DeviceType::BOILER, "Cascade MCM10", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {122, DeviceType::BOILER, "Proline", DeviceFlags::EMS_DEVICE_FLAG_NONE}, -{123, DeviceType::BOILER, "GBx72/Trendline/Cerapur/Greenstar Si", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{123, DeviceType::BOILER, "GB*72, Trendline, Cerapur, Greenstar Si", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {131, DeviceType::BOILER, "GB212", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {132, DeviceType::BOILER, "GC7000F", DeviceFlags::EMS_DEVICE_FLAG_NONE}, -{133, DeviceType::BOILER, "Logano GB125/KB195i/Logamatic MC110", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{133, DeviceType::BOILER, "Logano GB125/KB195i, Logamatic MC110", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {154, DeviceType::BOILER, "Greenstar 30Ri Compact", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {167, DeviceType::BOILER, "Cerapur Aero", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {168, DeviceType::BOILER, "Hybrid Heatpump", DeviceFlags::EMS_DEVICE_FLAG_HYBRID}, {170, DeviceType::BOILER, "Logano GB212", DeviceFlags::EMS_DEVICE_FLAG_NONE}, -{172, DeviceType::BOILER, "Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP}, +{172, DeviceType::BOILER, "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP}, {173, DeviceType::BOILER, "Geo 5xx", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP}, -{195, DeviceType::BOILER, "Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2", DeviceFlags::EMS_DEVICE_FLAG_NONE}, -{203, DeviceType::BOILER, "Logamax U122/Cerapur", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{195, DeviceType::BOILER, "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{203, DeviceType::BOILER, "Logamax U122, Cerapur", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {206, DeviceType::BOILER, "Ecomline Excellent", DeviceFlags::EMS_DEVICE_FLAG_NONE}, -{208, DeviceType::BOILER, "Logamax Plus/GB192/Condens GC9000/Greenstar ErP", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{208, DeviceType::BOILER, "Logamax Plus, GB192, Condens GC9000, Greenstar ErP", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {210, DeviceType::BOILER, "Cascade MC400", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {211, DeviceType::BOILER, "EasyControl Adapter", DeviceFlags::EMS_DEVICE_FLAG_NONE}, -{219, DeviceType::BOILER, "Greenstar HIU/Logamax kompakt WS170", DeviceFlags::EMS_DEVICE_FLAG_HIU}, -{234, DeviceType::BOILER, "Logamax Plus GB122/Condense 2300", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{219, DeviceType::BOILER, "Greenstar HIU, Logamax kompakt WS170", DeviceFlags::EMS_DEVICE_FLAG_HIU}, +{234, DeviceType::BOILER, "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // Controllers - 0x09 / 0x10 / 0x50 -{ 68, DeviceType::CONTROLLER, "BC10/RFM20", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09 +{ 68, DeviceType::CONTROLLER, "BC10, RFM20", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09 { 81, DeviceType::CONTROLLER, "CM10", DeviceFlags::EMS_DEVICE_FLAG_NONE}, { 84, DeviceType::CONTROLLER, "GB022", DeviceFlags::EMS_DEVICE_FLAG_NONE}, -{ 89, DeviceType::CONTROLLER, "BC10 GB142", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09 +{ 89, DeviceType::CONTROLLER, "BC10, GB142", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09 { 95, DeviceType::CONTROLLER, "HT3", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09 {114, DeviceType::CONTROLLER, "BC10", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09 {121, DeviceType::CONTROLLER, "MCM10", DeviceFlags::EMS_DEVICE_FLAG_NONE}, @@ -77,35 +77,35 @@ {241, DeviceType::CONTROLLER, "Condens 5000i", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x09 // Thermostat - not currently supporting write operations, like the Easy/100 types - 0x18 -{202, DeviceType::THERMOSTAT, "Logamatic TC100/Moduline Easy", DeviceFlags::EMS_DEVICE_FLAG_EASY | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18, cannot write -{203, DeviceType::THERMOSTAT, "EasyControl/CT200", DeviceFlags::EMS_DEVICE_FLAG_EASY | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18, cannot write +{202, DeviceType::THERMOSTAT, "Logamatic TC100, Moduline Easy", DeviceFlags::EMS_DEVICE_FLAG_EASY | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18, cannot write +{203, DeviceType::THERMOSTAT, "EasyControl, CT200", DeviceFlags::EMS_DEVICE_FLAG_EASY | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18, cannot write // Thermostat - Buderus/Nefit/Bosch specific - 0x17 / 0x10 / 0x18 / 0x19-0x1B for hc2-4 / 0x38 -{ 4, DeviceType::THERMOSTAT, "UI800/BC400", DeviceFlags::EMS_DEVICE_FLAG_BC400}, // 0x10 +{ 4, DeviceType::THERMOSTAT, "UI800, BC400", DeviceFlags::EMS_DEVICE_FLAG_BC400}, // 0x10 { 65, DeviceType::THERMOSTAT, "RC10", DeviceFlags::EMS_DEVICE_FLAG_RC20_N},// 0x17 { 67, DeviceType::THERMOSTAT, "RC30", DeviceFlags::EMS_DEVICE_FLAG_RC30_N},// 0x10 - based on RC35 -{ 77, DeviceType::THERMOSTAT, "RC20/Moduline 300", DeviceFlags::EMS_DEVICE_FLAG_RC20},// 0x17 +{ 77, DeviceType::THERMOSTAT, "RC20, Moduline 300", DeviceFlags::EMS_DEVICE_FLAG_RC20},// 0x17 { 78, DeviceType::THERMOSTAT, "Moduline 400", DeviceFlags::EMS_DEVICE_FLAG_RC30}, // 0x10 -{ 79, DeviceType::THERMOSTAT, "RC10/Moduline 100", DeviceFlags::EMS_DEVICE_FLAG_RC10},// 0x17 +{ 79, DeviceType::THERMOSTAT, "RC10, Moduline 100", DeviceFlags::EMS_DEVICE_FLAG_RC10},// 0x17 { 80, DeviceType::THERMOSTAT, "Moduline 200", DeviceFlags::EMS_DEVICE_FLAG_RC10}, // 0x17 { 86, DeviceType::THERMOSTAT, "RC35", DeviceFlags::EMS_DEVICE_FLAG_RC35}, // 0x10 -{ 90, DeviceType::THERMOSTAT, "RC10/Moduline 100", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17 +{ 90, DeviceType::THERMOSTAT, "RC10, Moduline 100", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17 { 93, DeviceType::THERMOSTAT, "RC20RF", DeviceFlags::EMS_DEVICE_FLAG_RC20}, // 0x19 { 94, DeviceType::THERMOSTAT, "RFM20 Remote", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x18 {151, DeviceType::THERMOSTAT, "RC25", DeviceFlags::EMS_DEVICE_FLAG_RC25}, // 0x17 -{157, DeviceType::THERMOSTAT, "RC200/CW100/CR120/CR50", DeviceFlags::EMS_DEVICE_FLAG_RC100}, // 0x18,, CR120 v22 is FLAG_BC400 -{158, DeviceType::THERMOSTAT, "RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410", DeviceFlags::EMS_DEVICE_FLAG_RC300}, // 0x10 -{165, DeviceType::THERMOSTAT, "RC100/CR10/Moduline 1000/1010", DeviceFlags::EMS_DEVICE_FLAG_RC100}, // 0x18, 0x38 +{157, DeviceType::THERMOSTAT, "RC200, CW100, CR120, CR50", DeviceFlags::EMS_DEVICE_FLAG_RC100}, // 0x18,, CR120 v22 is FLAG_BC400 +{158, DeviceType::THERMOSTAT, "RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410", DeviceFlags::EMS_DEVICE_FLAG_RC300}, // 0x10 +{165, DeviceType::THERMOSTAT, "RC100, CR10, Moduline 1000/1010", DeviceFlags::EMS_DEVICE_FLAG_RC100}, // 0x18, 0x38 {172, DeviceType::THERMOSTAT, "Rego 2000/3000", DeviceFlags::EMS_DEVICE_FLAG_R3000}, // 0x10 {215, DeviceType::THERMOSTAT, "Comfort RF", DeviceFlags::EMS_DEVICE_FLAG_CRF | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18 {216, DeviceType::THERMOSTAT, "CRF200S", DeviceFlags::EMS_DEVICE_FLAG_CRF | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18 {246, DeviceType::THERMOSTAT, "Comfort+2RF", DeviceFlags::EMS_DEVICE_FLAG_CRF | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18 -{253, DeviceType::THERMOSTAT, "Rego 3000/UI800/WSW196i/BC400", DeviceFlags::EMS_DEVICE_FLAG_BC400}, // 0x10 +{253, DeviceType::THERMOSTAT, "Rego 3000, UI800, Logatherm WLW186i/WSW196i, Logamatic BC400", DeviceFlags::EMS_DEVICE_FLAG_BC400}, // 0x10 // Thermostat - Sieger - 0x10 / 0x17 -{ 66, DeviceType::THERMOSTAT, "ES72/RC20", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17 or remote +{ 66, DeviceType::THERMOSTAT, "ES72, RC20", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17 or remote { 76, DeviceType::THERMOSTAT, "ES73", DeviceFlags::EMS_DEVICE_FLAG_RC30_N}, // 0x10 -{113, DeviceType::THERMOSTAT, "ES72/RC20", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17 +{113, DeviceType::THERMOSTAT, "ES72, RC20", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17 {156, DeviceType::THERMOSTAT, "ES79", DeviceFlags::EMS_DEVICE_FLAG_RC35}, // 0x10 // Thermostat - Junkers - 0x10 @@ -122,17 +122,17 @@ {192, DeviceType::THERMOSTAT, "FW120", DeviceFlags::EMS_DEVICE_FLAG_JUNKERS}, // Thermostat remote - 0x38 -{ 3, DeviceType::THERMOSTAT, "RT800/RC220", DeviceFlags::EMS_DEVICE_FLAG_RC100H}, +{ 3, DeviceType::THERMOSTAT, "RT800, RC220", DeviceFlags::EMS_DEVICE_FLAG_RC100H}, {200, DeviceType::THERMOSTAT, "RC100H", DeviceFlags::EMS_DEVICE_FLAG_RC100H}, -{249, DeviceType::THERMOSTAT, "TR120RF/CR20RF", DeviceFlags::EMS_DEVICE_FLAG_RC100H}, +{249, DeviceType::THERMOSTAT, "TR120RF, CR20RF", DeviceFlags::EMS_DEVICE_FLAG_RC100H}, // Solar Modules - 0x30 (for solar), 0x2A, 0x41 (for ww) { 73, DeviceType::SOLAR, "SM10", DeviceFlags::EMS_DEVICE_FLAG_SM10}, {101, DeviceType::SOLAR, "ISM1", DeviceFlags::EMS_DEVICE_FLAG_ISM}, {103, DeviceType::SOLAR, "ISM2", DeviceFlags::EMS_DEVICE_FLAG_ISM}, {162, DeviceType::SOLAR, "SM50", DeviceFlags::EMS_DEVICE_FLAG_SM100}, -{163, DeviceType::SOLAR, "SM100/MS100", DeviceFlags::EMS_DEVICE_FLAG_SM100}, -{164, DeviceType::SOLAR, "SM200/MS200", DeviceFlags::EMS_DEVICE_FLAG_SM100}, +{163, DeviceType::SOLAR, "SM100, MS100", DeviceFlags::EMS_DEVICE_FLAG_SM100}, +{164, DeviceType::SOLAR, "SM200, MS200", DeviceFlags::EMS_DEVICE_FLAG_SM100}, // Mixer Modules - 0x20-0x27 for HC, 0x28-0x29 for WWC and 0x11 for the MP100 { 69, DeviceType::MIXER, "MM10", DeviceFlags::EMS_DEVICE_FLAG_MM10}, @@ -163,7 +163,7 @@ {206, DeviceType::CONNECT, "Easy Connect", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // Wireless sensor base - 0x50 -{218, DeviceType::CONNECT, "M200/RFM200", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{218, DeviceType::CONNECT, "M200, RFM200", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {236, DeviceType::CONNECT, "Wireless sensor base", DeviceFlags::EMS_DEVICE_FLAG_NONE}, {238, DeviceType::CONNECT, "Wireless sensor base", DeviceFlags::EMS_DEVICE_FLAG_NONE}, @@ -171,7 +171,7 @@ { 71, DeviceType::SWITCH, "WM10", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // EM10/100 extension module, pump module - 0x15 -{ 243, DeviceType::EXTENSION, "EM10/EM100", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{ 243, DeviceType::EXTENSION, "EM10, EM100", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // Wireless outdoor sensor T1RF - 0x16 { 220, DeviceType::EXTENSION, "T1RF", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // 0x16 @@ -180,8 +180,8 @@ { 74, DeviceType::ALERT, "EM10", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // Gateways - 0x48 -{189, DeviceType::GATEWAY, "KM200/MB LAN 2", DeviceFlags::EMS_DEVICE_FLAG_NONE}, -{252, DeviceType::GATEWAY, "K30RF/MX300", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{189, DeviceType::GATEWAY, "KM200, MB LAN 2", DeviceFlags::EMS_DEVICE_FLAG_NONE}, +{252, DeviceType::GATEWAY, "K30RF, MX300", DeviceFlags::EMS_DEVICE_FLAG_NONE}, // Generic - 0x40 or other with no product-id and no version {0, DeviceType::GENERIC, "unknown", DeviceFlags::EMS_DEVICE_FLAG_NONE} diff --git a/src/mqtt.cpp b/src/mqtt.cpp index d0b42dcc9..3bbdf2118 100644 --- a/src/mqtt.cpp +++ b/src/mqtt.cpp @@ -95,7 +95,8 @@ void Mqtt::subscribe(const uint8_t device_type, const std::string & topic, mqtt_ // register in our libary with the callback function. // We store the original topic string without base - mqtt_subfunctions_.emplace_back(device_type, std::move(topic), std::move(cb)); + // removed std::move(topic) in 3.7.0-dev.43 + mqtt_subfunctions_.emplace_back(device_type, topic, cb); if (!enabled() || !connected()) { return; @@ -135,7 +136,7 @@ void Mqtt::loop() { uint32_t currentMillis = uuid::get_uptime(); // send heartbeat - if ((currentMillis - last_publish_heartbeat_ > publish_time_heartbeat_)) { + if (currentMillis - last_publish_heartbeat_ > publish_time_heartbeat_) { last_publish_heartbeat_ = currentMillis; EMSESP::system_.send_heartbeat(); // send heartbeat } @@ -265,7 +266,8 @@ void Mqtt::on_message(const char * topic, const uint8_t * payload, size_t len) { JsonDocument input_doc; JsonDocument output_doc; - JsonObject input, output; + JsonObject input; + JsonObject output; // convert payload into a json doc // if the payload doesn't not contain the key 'value' or 'data', treat the whole payload as the 'value' @@ -524,8 +526,6 @@ void Mqtt::on_connect() { // publish to the last will topic (see Mqtt::start() function) to say we're alive queue_publish_retain("status", "online", false); // with retain off - - // mqtt_publish_fails_ = 0; // reset fail count to 0 } // Home Assistant Discovery - the main master Device called EMS-ESP diff --git a/src/mqtt.h b/src/mqtt.h index 9e822caab..4f88c59bd 100644 --- a/src/mqtt.h +++ b/src/mqtt.h @@ -256,7 +256,8 @@ class Mqtt { const std::string topic_; // short topic name mqtt_sub_function_p mqtt_subfunction_; // can be empty - MQTTSubFunction(uint8_t device_type, const std::string && topic, mqtt_sub_function_p mqtt_subfunction) + // replaced &&topic with &topic in 3.7.0-dev.43, so we prevent the std:move later + MQTTSubFunction(uint8_t device_type, const std::string & topic, mqtt_sub_function_p mqtt_subfunction) : device_type_(device_type) , topic_(topic) , mqtt_subfunction_(mqtt_subfunction) { @@ -265,7 +266,6 @@ class Mqtt { static std::vector mqtt_subfunctions_; // list of mqtt subscribe callbacks for all devices - // uint32_t last_mqtt_poll_ = 0; uint32_t last_publish_boiler_ = 0; uint32_t last_publish_thermostat_ = 0; uint32_t last_publish_solar_ = 0; diff --git a/src/shuntingYard.hpp b/src/shuntingYard.hpp index 7f3a69b84..e2124db3d 100644 --- a/src/shuntingYard.hpp +++ b/src/shuntingYard.hpp @@ -8,19 +8,12 @@ // https://ideone.com/VocUTq // // License: -// If you use this code in binary / compiled / un-commented (removing all text comments) form, -// you can use it under CC0 license. -// -// But if you use this code as source code / readable text, since main content of this code is -// their notes, I recommend you to indicate notices which conform CC-BY-SA. For example, -// -// --- --- -// YOUR-CONTENT uses the following materials. +// This code uses the following materials. // (1) Wikipedia article [Shunting-yard algorithm](https://en.wikipedia.org/wiki/Shunting-yard_algorithm), // which is released under the [Creative Commons Attribution-Share-Alike License 3.0](https://creativecommons.org/licenses/by-sa/3.0/). // (2) [Implementation notes for unary operators in Shunting-Yard algorithm](https://stackoverflow.com/a/5240912) by Austin Taylor // which is released under the [Creative Commons Attribution-Share-Alike License 2.5](https://creativecommons.org/licenses/by-sa/2.5/). -// --- --- +// // copy from https://gist.github.com/t-mat/b9f681b7591cdae712f6 // modified MDvP, 06.2024 // @@ -75,7 +68,7 @@ std::deque exprToTokens(const std::string & expr) { ++p; } const auto s = std::string(b, p); - tokens.push_back(Token{Token::Type::String, s, -3}); + tokens.emplace_back(Token::Type::String, s, -3); if (*p == '\0') { --p; } @@ -85,7 +78,7 @@ std::deque exprToTokens(const std::string & expr) { ++p; } const auto s = std::string(b, p); - tokens.push_back(Token{Token::Type::String, s, -2}); + tokens.emplace_back(Token::Type::String, s, -2); --p; } else if (*p == '"') { ++p; @@ -94,7 +87,7 @@ std::deque exprToTokens(const std::string & expr) { ++p; } const auto s = std::string(b, p); - tokens.push_back(Token{Token::Type::String, s, -3}); + tokens.emplace_back(Token::Type::String, s, -3); if (*p == '\0') { --p; } @@ -105,7 +98,7 @@ std::deque exprToTokens(const std::string & expr) { ++p; } const auto s = std::string(b, p); - tokens.push_back(Token{Token::Type::String, s, -3}); + tokens.emplace_back(Token::Type::String, s, -3); if (*p == '\0') { --p; } @@ -115,7 +108,7 @@ std::deque exprToTokens(const std::string & expr) { ++p; } const auto s = std::string(b, p); - tokens.push_back(Token{Token::Type::Number, s, -4}); + tokens.emplace_back(Token::Type::Number, s, -4); --p; } else { Token::Type token = Token::Type::Operator; @@ -214,7 +207,7 @@ std::deque exprToTokens(const std::string & expr) { break; } const auto s = std::string(1, c); - tokens.push_back(Token{token, s, precedence, rightAssociative}); + tokens.emplace_back(token, s, precedence, rightAssociative); } } @@ -227,7 +220,7 @@ std::deque shuntingYard(const std::deque & tokens) { std::vector stack; // While there are tokens to be read: - for (auto token : tokens) { + for (auto const & token : tokens) { // Read a token switch (token.type) { case Token::Type::Number: @@ -302,7 +295,6 @@ std::deque shuntingYard(const std::deque & tokens) { case Token::Type::Unknown: default: return {}; - break; } } @@ -355,7 +347,8 @@ std::string commands(std::string & expr, bool quotes = true) { if (strstr(cmd, "/value") == nullptr) { strlcat(cmd, "/value", sizeof(cmd) - 6); } - JsonDocument doc_out, doc_in; + JsonDocument doc_out; + JsonDocument doc_in; JsonObject output = doc_out.to(); JsonObject input = doc_in.to(); std::string cmd_s = "api/" + std::string(cmd); @@ -589,7 +582,6 @@ std::string calculate(const std::string & expr) { result += s; } return result; - // return stack.back(); } // check for multiple instances of ? : diff --git a/src/telegram.cpp b/src/telegram.cpp index d1afce938..54e7ec799 100644 --- a/src/telegram.cpp +++ b/src/telegram.cpp @@ -243,7 +243,7 @@ void RxService::add_empty(const uint8_t src, const uint8_t dest, const uint16_t // send out request to EMS bus for all devices void TxService::start() { // grab the bus ID and tx_mode - EMSESP::webSettingsService.read([&](WebSettings & settings) { + EMSESP::webSettingsService.read([&](WebSettings const & settings) { ems_bus_id(settings.ems_bus_id); tx_mode(settings.tx_mode); }); @@ -418,30 +418,6 @@ void TxService::send_telegram(const QueuedTxTelegram & tx_telegram) { tx_state(telegram->operation); // tx now in a wait state } -/* -// send an array of bytes as a telegram -// we need to calculate the CRC and append it before sending -// this function is fire-and-forget. there are no checks or post-send validations -void TxService::send_telegram(const uint8_t * data, const uint8_t length) { - uint8_t telegram_raw[EMS_MAX_TELEGRAM_LENGTH]; - - for (uint8_t i = 0; i < length; i++) { - telegram_raw[i] = data[i]; - } - telegram_raw[length] = calculate_crc(telegram_raw, length); // append CRC - - tx_state(Telegram::Operation::NONE); // no post validation needed - - // send the telegram to the UART Tx - uint16_t status = EMSuart::transmit(telegram_raw, length); - - if (status == EMS_TX_STATUS_ERR) { - LOG_ERROR("Failed to transmit Tx via UART."); - increment_telegram_fail_count(); // another Tx fail - } -} -*/ - void TxService::add(const uint8_t operation, const uint8_t dest, const uint16_t type_id, @@ -547,10 +523,8 @@ void TxService::add(uint8_t operation, const uint8_t * data, const uint8_t lengt LOG_DEBUG("New Tx [#%d] telegram, length %d", tx_telegram_id_, message_length); if (front && (operation != Telegram::Operation::TX_RAW || EMSESP::response_id() == 0)) { - // tx_telegrams_.push_front(qtxt); // add to front of queue tx_telegrams_.emplace_front(tx_telegram_id_++, std::move(telegram), false, validate_id); // add to front of queue } else { - // tx_telegrams_.push_back(qtxt); // add to back of queue tx_telegrams_.emplace_back(tx_telegram_id_++, std::move(telegram), false, validate_id); // add to back of queue } if (validate_id != 0) { diff --git a/src/telegram.h b/src/telegram.h index c18dabe9c..892d7a6a9 100644 --- a/src/telegram.h +++ b/src/telegram.h @@ -285,7 +285,8 @@ class RxService : public EMSbus { const std::shared_ptr telegram_; ~QueuedRxTelegram() = default; - QueuedRxTelegram(uint16_t id, std::shared_ptr && telegram) + // removed && from telegram in 3.7.0-dev.43 + QueuedRxTelegram(uint16_t id, std::shared_ptr telegram) : id_(id) , telegram_(std::move(telegram)) { } @@ -414,7 +415,8 @@ class TxService : public EMSbus { const uint16_t validateid_; ~QueuedTxTelegram() = default; - QueuedTxTelegram(uint16_t id, std::shared_ptr && telegram, bool retry, uint16_t validateid) + // replaced && im std::shared_ptr telegram in 3.7.0-dev.43 + QueuedTxTelegram(uint16_t id, std::shared_ptr telegram, bool retry, uint16_t validateid) : id_(id) , telegram_(std::move(telegram)) , retry_(retry) diff --git a/src/version.h b/src/version.h index e0e7948ea..de8b8bc67 100644 --- a/src/version.h +++ b/src/version.h @@ -1 +1 @@ -#define EMSESP_APP_VERSION "3.7.0-dev.42" +#define EMSESP_APP_VERSION "3.7.0-dev.43" diff --git a/src/web/WebStatusService.cpp b/src/web/WebStatusService.cpp index 1cf9f7cdb..378e44cf1 100644 --- a/src/web/WebStatusService.cpp +++ b/src/web/WebStatusService.cpp @@ -255,7 +255,7 @@ bool WebStatusService::exportData(JsonObject root, std::string & type) { } else if (type == "entities") { System::extractSettings(EMSESP_CUSTOMENTITY_FILE, "Entities", root); } else if (type == "allvalues") { - root.clear(); // don't need the "type" key + root.clear(); // don't need the "type" key added to the output allvalues(root); } else { return false;