From 7b216ced7b3f54cdcdd7b76ebe1eb78fb864aaab Mon Sep 17 00:00:00 2001 From: TShapinsky Date: Fri, 10 May 2024 10:18:10 -0600 Subject: [PATCH] update refrig case model --- tests/integration/models/refrig_case_osw/in.idf | 8 +++++--- .../models/refrig_case_osw/measures/prep_idf/measure.rb | 1 + 2 files changed, 6 insertions(+), 3 deletions(-) diff --git a/tests/integration/models/refrig_case_osw/in.idf b/tests/integration/models/refrig_case_osw/in.idf index 90b5dc13..d3ab0867 100644 --- a/tests/integration/models/refrig_case_osw/in.idf +++ b/tests/integration/models/refrig_case_osw/in.idf @@ -1,4 +1,4 @@ - Version,23.1; + Version,24.1; Building, Refrig Case Model, !- Name @@ -276,7 +276,7 @@ Light Sch, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} - 10.764, !- Watts per Zone Floor Area {W/m2} + 10.764, !- Watts per Floor Area {W/m2} , !- Watts per Person {W/person} 0, !- Return Air Fraction 0.7, !- Fraction Radiant @@ -289,7 +289,7 @@ Always On, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 500, !- Design Level {W} - , !- Watts per Zone Floor Area {W/m2} + , !- Watts per Floor Area {W/m2} , !- Watts per Person {W/person} 0, !- Fraction Latent 0.7, !- Fraction Radiant @@ -562,6 +562,7 @@ , !- No Load Fraction of Autosized Heating Supply Air Flow Rate , !- No Load Supply Air Flow Rate Per Unit of Capacity During Cooling Operation {m3/s-W} , !- No Load Supply Air Flow Rate Per Unit of Capacity During Heating Operation {m3/s-W} + No, !- No Load Supply Air Flow Rate Control Set To Low Speed 80; !- Maximum Supply Air Temperature {C} OutdoorAir:Node, @@ -605,6 +606,7 @@ , !- Evaporative Condenser Air Flow Rate {m3/s} , !- Evaporative Condenser Pump Rated Power Consumption {W} 0, !- Crankcase Heater Capacity {W} + , !- Crankcase Heater Capacity Function of Temperature Curve Name 10, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation {C} , !- Supply Water Storage Tank Name , !- Condensate Collection Water Storage Tank Name diff --git a/tests/integration/models/refrig_case_osw/measures/prep_idf/measure.rb b/tests/integration/models/refrig_case_osw/measures/prep_idf/measure.rb index 5f605227..e534638d 100644 --- a/tests/integration/models/refrig_case_osw/measures/prep_idf/measure.rb +++ b/tests/integration/models/refrig_case_osw/measures/prep_idf/measure.rb @@ -93,6 +93,7 @@ def run(workspace,runner,usr_args) end runner.workflow.absoluteFilePaths.each {|p| o.setString(6,p.to_s) if p.to_s.include?('python')} end + return true end end