With simulated data emulated on the firmware, the current algorithms return a cross correlation of (400ns, 1400ns, and 2400ns) when the shifts are actually (1us, 2us, 3us). This points to a possible systemic issue in the way cross correlations are performed on the device and should be investigated further.