-
MachineConfig objects should be complete source of machine configuration at install / first-boot for a machine.
-
MachineConfig objects should be the source of machine configuration during upgrades.
-
The MachineConfig served to the machines should be static and there should be no links to remote locations for dynamic configuration. This includes both remote sources for Ignition and remote files.
-
Define a way to merge multiple MachineConfigs.
- Updates from the remote sources for Ignition config will not be actively applied.
The machines using RHCOS
will be configured using an Ignition config served to the machines at first boot. An in-cluster Ignition endpoint will serve these Ignition configs to new machines based on the MachineConfig object defined.
Also during upgrades the MachineConfigDaemon running on these machines will use the defined MachineConfig object to upgrade the machine's configurations.
Users will not be allowed to change the MachineConfig object defined by openshift. Although, users will create new MachineConfig objects for their customization. Therefore the MachineConfig object used by the in-cluster Ignition server and daemon running on the machines has to be a merged version.
The MachineConfig object used by in-cluster Ignition server and daemon running on the machine should be a static definition of all the resources. Users might create MachineConfig objects that have links to remote Ignition configs, but at merge time, a snapshot of the remote Ignition config should be used to create the merged MachineConfig. The same is valid for remote files, at merge time the files are fetched and the contents are verified and replaced in-place the final merged MachineConfig.
MachineConfig objects can be created by both the OpenShift platform and users to define machine configurations. There is a final "rendered" MachineConfig object (prefixed with rendered-
) that is the union of its inputs.
-
The rendered MachineConfig object contains merged spec of all the different MachineConfig objects that are valid for the machine.
-
To ensure the configuration does not change unexpectedly between usage, all remote content referenced in the ignition config is retrieved and embedded into the merged MachineConfig at the time of generation.
To ensure all the machines see the same configurations, remote sources need to be resolved to a snapshot at generation time.
type MachineConfig struct {
metav1.TypeMeta `json:",inline"`
metav1.ObjectMeta `json:"metadata,omitempty"`
Spec MachineConfigSpec `json:spec`
}
type MachineConfigSpec struct {
// Config is a Ignition Config object.
Config ign.Config `json:"config"`
KernelArguments []string `json:"kernelArguments"`
Extensions []string `json:"extensions"`
Fips bool `json:"fips"`
KernelType string `json:"kernelType"`
}
The actual custom resource manifest then could look like this if you are applying it to cluster on version >= 4.7:
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
name: worker-2864988432
spec:
config:
ignition:
version: 3.2.0
storage:
files:
- contents:
source: data:,%20
mode: 384
path: /root/myfile
and like this if you are applying it to a cluster on version < 4.6:
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
name: worker-2864988432
spec:
config:
ignition:
version: 2.2.0
storage:
files:
- contents:
source: data:,%20
filesystem: root
mode: 384
path: /root/myfile
Notice how it's the usual Ignition config object inplace, not as a JSON
string -- also note the casing follows the json:
markers in the definition above, of course this follows for the
Ignition config keys as well.
-
For each MachineConfig object,
a. Use the Ignition's
internal
package to render a valid Ignition config. Ignition render fetches remote sources and then appends/replaces inline config. More Infob. Ignition does not fetch remote sources for files in render. Run fetcher separately to load the remote files.
-
Use Ignition's append to merge all the Ignition configs generated above.
- Use the openshift defined Ignition config as base and append all the other Ignition configs in a pre-defined order.
This extends the host's kernel arguments. Use this for e.g. nosmt. As of OpenShift 4.3, you can set this field for either "day 1" (install time) or "day 2" configuration once a cluster has been created. See installer docs on how to set them as install-time MachineConfig objects. For "day 2" operation you can also add them as a similar machineconfig, incurring a reboot.
Example MachineConfig to change kernel log level:
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
labels:
machineconfiguration.openshift.io/role: "master"
name: 99-master-kargs-loglevel
spec:
kernelArguments:
- 'loglevel=7'
Note that for 4.2 clusters this is only supported as a "day 2" operation.
On a 4.2 based OCP cluster if we already have kernel arguments applied using MachineConfig and then we try to create a new node using openshift-machine-api, existing kargs won't get applied. This behaviour is because 4.2 doesn't know how to process kernel arguments during firstboot on a newly spun node. See bug#1766346 for more information.
The best way to fix this issue is by getting the bootimage updated to 4.3 or later version which can be tracked at enhancement proposal .
Until we have the enhancement implemented it can be done manually by updating the bootimage in machineset.
Example:
Suppose we have a 4.2 cluster created on AWS and have applied karg foo
to the cluster with the following MachineConfig:
$ cat worker-karg.yaml
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
labels:
machineconfiguration.openshift.io/role: worker
name: worker-kargs
spec:
kernelArguments:
- foo
The first step is to upgrade the cluster to OCP 4.3 or later version. Once the cluster has been successfully upgraded, list the available machinesets:
$ oc get machineset -n openshift-machine-api
NAME DESIRED CURRENT READY AVAILABLE AGE
ci-ln-bx6fgqt-d5d6b-89fn7-worker-us-east-1b 2 2 2 2 79m
ci-ln-bx6fgqt-d5d6b-89fn7-worker-us-east-1c 1 1 1 1 79m
In our example, let's edit the bootimage in machineset ci-ln-bx6fgqt-d5d6b-89fn7-worker-us-east-1c with corresponding 4.3 bootimage. For 4.4, a list of bootimages for different platforms and regions are available here, checkout the respective OCP release branch in the repo for the corresponding release. Since the cluster was created in AWS in the us-east-1 region, we will update the ami id to ami-0543fbfb4749f3c3b with the following command:
$ oc edit machineset ci-ln-bx6fgqt-d5d6b-89fn7-worker-us-east-1c -n openshift-machine-api
Similarly, we can update the bootimage for the rest of the machinesets too. Once the bootimage has been updated, create a node by scaling up machineset replicas.
$ oc scale --replicas=2 machineset ci-ln-9jk9j3b-d5d6b-kw7lr-worker-us-east-1c -n openshift-machine-api
When a machine boots with nosmt
Kernel Argument, it disables multi-threading on that host and the system will only utilize physical CPU cores. While applying nosmt
on any node in the cluster, ensure that enough CPU resources are available to schedule all pods, otherwise it can lead to a degraded cluster. For example: a basic 3 master and 3 worker node cluster having 2 physical CPU cores on each node should be fine.
This feature is available with OCP 4.4 and onward releases as both day 1
and day 2
operation. It allows to choose between traditional and Real Time (RT) kernel on an RHCOS node. Supported values are
""
or default
for traditional kernel and realtime
for RT kernel.
To set kernelType field during cluster install, see the installer guide.
For day 2, create a MachineConfig and apply to the cluster using oc create -f
Example MachineConfig to switch to RT kernel on worker nodes:
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
labels:
machineconfiguration.openshift.io/role: "worker"
name: worker-kerneltype
spec:
kernelType: realtime
Note: The RT kernel lowers throughput (performance) in return for improved worst-case latency bounds. This feature is intended only for use cases that require consistent low latency. For more information, see the Linux Foundation wiki and the RHEL RT portal.
RHCOS is a minimal OCP focused OS which provides capabilities common across all the platforms. With extensions support, OCP 4.6 and onward users can enable a limited set of additional functionality on the RHCOS nodes. In OCP 4.6 the supported extensions is usbguard
. In OCP 4.8 the supported extensions are usbguard
and sandboxed-containers
.
Extensions can be installed by creating a MachineConfig object. Extensions can be enabled as both day1 and day2. Check installer guide to enable extensions during cluster install.
Example MachineConfig to install usbguard on an existing cluster on worker nodes:
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
labels:
machineconfiguration.openshift.io/role: worker
name: worker-extensions
spec:
config:
ignition:
version: 3.2.0
extensions:
- usbguard
This allows to enable/disable FIPS mode. If any of the configuration has FIPS enabled, it'll be set. A similar restriction applies to this as for KernelArguments
above.
Enabling FIPS mode is a Day 1 operation, set at install time. You cannot enable FIPS via a MachineConfig as a Day2 operation.
You should not attempt to set this field; it is controlled by the operator and injected directly into the final rendered-
config.
For more information, see OSUpgrades.md.