Notifications
You must be signed in to change notification settings - Fork 225
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Controlling Tool Output while using a newer version of the Robotiq Gripper URCap is not possible #956
Comments
I don't quite understand how this relates to our ROS 2 driver. We use the RTDE protocol to read the robot state, move the arm and set i/os. This did not change. What exactly do you want to achieve? Why do you need to be able to directly set tool i/os if the robotiq urcap is used? |
The robotiq 2f-85 only uses one of the outputs as power supply. We use the second one to control an electromagnet mounted at the wrist.
As neither UR nor Robotiq want to do anything about this the only way of having this very convenient feature is by changing the way the IOs are controlled in the ROS driver.... |
I see, that makes sense. We are aware that using RTDE for IOs can lead to problems when integrating with additional equipment (also e.g. if you try to control the UR IOs from a PLC while controlling the joints through ROS). Enabling IO control through a different interface is on our roadmap, but we don't have a timeline for that yet. @urrsk do you maybe have some more information on this specific conflict with robotiq? |
@firesurfer you have a good point and we are aware about it. In general, we are missing a good way to integrate URCaps with the use of the ROS drivers. |
@urrsk |
@firesurfer Our current way of managing the Tool Connector have it limitations. The intend with selecting one owner is that they are in control. In the past we have seen cases with other tool manufactures tools have been disturbed by the presence of Robotiqs URCap, even when they were selected as owner of the tool connector. That is what Robotiq have fixed here. |
@EbbeFuglsang Thanks for the info.
Thats what we are currently doing. But given that there were some necessary updates in the past I would like being able to run the newest version of the URCap to avoid bad surprises in the future. Also I would argue that from a user point of view: If I select: Controlled by user, than I would like to be able to control it myself ;) |
Affected ROS2 Driver version(s)
Prob. all
Used ROS distribution.
Iron
Which combination of platform is the ROS driver running on.
Ubuntu Linux with standard kernel
How is the UR ROS2 Driver installed.
Build both the ROS driver and UR Client Library from source
Which robot platform is the driver connected to.
UR E-series robot
Robot SW / URSim version(s)
5.14.6.123463
How is the ROS driver used.
Headless without using the teach pendant
Issue details
We have a UR16e with a Robotiq 2f-85 connected to the wrist.
We currently use the Robotiq Gripper URCap on the arm in order to control the gripper. The URCap opens a TCP Socket which allows to remotely control the gripper as well as controller the gripper with the Teachpanel, what is quite convenient.
But when upgrading the gripper URCap from UCG-1.8.13.22852 to anything higher we can not select in the Installation tab -> ToolIO -> Controlled by: User, as the URCap will then refuse the interact with the gripper.
I contacted the Robotiq support and UR support. Basically the answer was. Yes this is intended (but they didn't tell me why). BUT: When selecting: ToolIO -> Controlled by: Robotiq Gripper UrCap it is still possible to control the IO via the script command:
set_tool_digital_out
(Confirmed by the UR support. I didn' test it myself to be honest).When taking a look at the external control urscript I can not find this command being used to set the tool io. (But we definitely can via the ROS2 Driver). I guess the IOs are set via a different control method.
So my request is: Support setting the tool IO via the urscript in order to workaround with issues in combination with the Robotiq Gripper UrCap. Perhaps you have a better contact to UR and can figure out why Robotiq was forced to include this check...
Relevant log output
No response
Accept Public visibility
The text was updated successfully, but these errors were encountered: