Sharp7Reactive

Release Licence Nuget Version

This is an additional library for the usage if Sharp7. It combines the S7 communication library with the power of System.Reactive.

Main features

  • Completly free and ready for usage (the library is already widely used in many enterprise environments)
  • Connection status observation and auto-reconnect
  • Type safe and with generics
  • Threadsafe (Sharp7 is basically not threadsafe)

Quick start

Install the Sharp7.Rx Nuget package.

The example below shows you how to create and use the Sharp7Rx PLC.

using (var disposables = new CompositeDisposable())
{
    // create a new PLC
    var plc = new Sharp7Plc("10.30.3.10", 0, 2);
    disposables.Add(plc);
    
    // initialize and connect to the plc
    await plc.InitializeConnection();
    
    await plc.SetValue<bool>("DB2.DBX0.4", true); // set a bit
    var value = await plc.GetValue<short>("DB2.Int4"); // get an 16 bit integer
    Console.WriteLine(value)

    // create a nofication for data change in the plc
    var notification = plc.CreateNotification<bool>("DB1.DBX0.2", TransmissionMode.OnChange)
                          .Where(b => b) //select rising edge
                          .Do(_ => doStuff())
                          .Subscribe();
    disposables.Add(notification);
    
    //wait for enter before ending the program
    Console.ReadLine();
    
}

The best way to test your PLC application is running your SoftPLC locally.

Examples

This library comes with integrated LinqPad examples - even for the free edition. Just download the Sharp7.Rx Nuget package after pressing Ctrl + Shift + P and browse the "Samples".

Sharp7Monitor is a console application for monitoring S7 variables over RFC1006, based on this library.

Addressing rules

Sharp7Reactive uses a syntax for identifying addresses similar to official siemens syntax. Every address has the form (case unsensitive) DB<number>.<TYPE><Start>.<Length/Position>.

Example Explaination
DB42.Int4 or
DB42.DBD4
Datablock 42, 16 bit integer from bytes 4 to 5 (zero based index)
DB42.Bit0.7 or
DB42.DBX0.7
Datablock 42, bit from byte 0, position 7
DB42.Byte4.25 or
DB42.DBB4.25
Datablock 42, 25 bytes from byte 4 to 29 (zero based index)

Here is a table of supported data types:

.Net Type Identifier Description Length or bit Example Example remark
bool bit, dbx Bit as boolean value Bit index (0 .. 7) Db200.Bit2.2 Reads bit 3
byte byte, dbb, b* 8 bit unsigned integer Db200.Byte4
byte[] byte, dbb, b* Array of bytes Array length in bytes Db200.Byte4.16
short int, dbw, w* 16 bit signed integer Db200.Int4
ushort uint 16 bit unsigned integer Db200.UInt4
int dint, dbd 32 bit signed integer Db200.DInt4
uint udint 32 bit unsigned integer Db200.UDInt4
long lint 64 bit signed integer Db200.LInt4
ulong ulint, dul*, dulint*, dulong* 64 bit unsigned integer Db200.ULInt4
float real, d* 32 bit float Db200.Real4
double lreal 64 bit float Db200.LReal4
string string, s* ASCII text string with string size String length in bytes (1 .. 254) Db200.String4.16 Uses 18 bytes = 16 + 2
string wstring UTF-16 Big Endian text string with string size String length in characters (1 .. 16382) Db200.WString4.16 Uses 36 bytes = 16 * 2 + 4
string byte[] ASCII string as byte array String length in bytes Db200.Byte4.16 Uses 16 bytes

Identifiers marked with * are kept for compatability reasons and might be removed in the future.

Performance considerations

Frequent reads of variables using GetValue can cause performance pressure on the S7 PLC, resulting in an increase of cycle time.

If you frequently read variables, like polling triggers, use CreateNotification. Internally all variable polling initialized with CreateNotification is pooled to a single (or some) multi-variable-reads.

You can provide a cycle time (delay between consecutive multi variable reads) in the Sharp7Plc constructor:

public Sharp7Plc(string ipAddress, int rackNumber, int cpuMpiAddress, int port = 102, TimeSpan? multiVarRequestCycleTime = null)

The default value for multiVarRequestCycleTime is 100 ms, the minimal value is 5 ms.