Notifications
You must be signed in to change notification settings - Fork 0
/
registers.txt
92 lines (89 loc) · 8.08 KB
/
registers.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
Reference: https://diysolarforum.com/resources/solis-grid-tied-inverters-2018-rs485-modbus-communication-protocol.272/download
Registers may vary depending on the model of the inverter. THe following is for a Solis single-phase, 3-MPPT 7.6kW Solis 4G Series B2 inverter.
Register: 02999 Value: 00000178 (0x00b2) - PRODUCT MODEL
Register: 03000 Value: 00000024 (0x0018) - DSP SOFTWARE VERSION (HEX)
Register: 03001 Value: 00000053 (0x0035) - LCD SOFTWARE (HEX)
Register: 03002 Value: 00000000 (0x0000) - AC OUTPUT TYPE (0=SINGLE, 1=3P4WIRES, 2=3P3WIRES, 3=3P4WIRES OR 3P3WIRES BOTH AVAILABLE)
Register: 03003 Value: 00000003 (0x0003) - DC INPUT TYPE (0=1 DC INPUT, 1 2=DC INPUT, 2=3 DC INPUT, ETC.)
Register: 03004 Value: 00000000 (0x0000) - AC POWER (1 W)
Register: 03005 Value: 00001750 (0x06d6) - AC POWER (1 W)
Register: 03006 Value: 00000000 (0x0000) - DC POWER (1 W)
Register: 03007 Value: 00001855 (0x073f) - DC POWER (1 W)
Register: 03008 Value: 00000000 (0x0000) - TOTAL YIELD (0.1 kWh)
Register: 03009 Value: 00033528 (0x82f8) - TOTAL YIELD (0.1 kWh)
Register: 03010 Value: 00000000 (0x0000) - THIS MONTH YIELD (0.1 kWh)
Register: 03011 Value: 00000646 (0x0286) - THIS MONTH YIELD (0.1 kWh)
Register: 03012 Value: 00000000 (0x0000) - PREVIOUS MONTH YIELD (0.1 kWh)
Register: 03013 Value: 00000593 (0x0251) - PREVIOUS MONTH YIELD (0.1 kWh)
Register: 03014 Value: 00000489 (0x01e9) - DAILY YIELD (0.1 kWh)
Register: 03015 Value: 00000034 (0x0022) - DAILY YIELD (0.1 kWh)
Register: 03016 Value: 00000000 (0x0000) - ANNUAL YIELD (0.1 kWh)
Register: 03017 Value: 00001588 (0x0634) - ANNUAL YIELD (0.1 kWh)
Register: 03018 Value: 00000000 (0x0000) - PREVIOUS ANNUAL YIELD (0.1 kWh)
Register: 03019 Value: 00010747 (0x29fb) - PREVIOUS ANNUAL YIELD (0.1 kWh)
Register: 03020 Value: 00000000 (0x0000) - RESERVED
Register: 03021 Value: 00002146 (0x0862) - DC 1 VOLTAGE (0.1 V)
Register: 03022 Value: 00000017 (0x0011) - DC 1 AMPS (0.1 A)
Register: 03023 Value: 00002916 (0x0b64) - DC 2 VOLTAGE (0.1 V)
Register: 03024 Value: 00000026 (0x001a) - DC 2 AMPS (0.1 A)
Register: 03025 Value: 00003617 (0x0e21) - DC 3 VOLTAGE (0.1 V)
Register: 03026 Value: 00000021 (0x0015) - DC 3 AMPS (0.1 A)
Register: 03027 Value: 00000008 (0x0008) - DC 4 VOLTAGE (0.1 V)
Register: 03028 Value: 00000001 (0x0001) - DC 4 AMPS (0.1 A)
Register: 03029 Value: 00000000 (0x0000) - RESERVED
Register: 03030 Value: 00001984 (0x07c0) - GROUND VOLTAGE (0.1 V)
Register: 03031 Value: 00003997 (0x0f9d) - DC BUSBAR VOLTAGE (0.1 V)
Register: 03032 Value: 00000000 (0x0000) - DC HALF-BUSBAR VOLTAGE (0.1 V)
Register: 03033 Value: 00000000 (0x0000) - AB LINE VOLTAGE / A PHASE VOLTAGE (0.1 V)
Register: 03034 Value: 00000000 (0x0000) - BC LINE VOLTAGE / B PHASE VOLTAGE (0.1 V)
Register: 03035 Value: 00002420 (0x0974) - CA LINE VOLTAGE / C PHASE VOLTAGE (SINGLE PHASE MAIN) (0.1 V)
Register: 03036 Value: 00000000 (0x0000) - A PHASE CURRENT (0.1 A)
Register: 03037 Value: 00000000 (0x0000) - B PHASE CURRENT (0.1 A)
Register: 03038 Value: 00000075 (0x004b) - C PHASE CURRENT (AC AMPS) (SINGLE PHASE MAIN) (0.1 A)
Register: 03039 Value: 00000000 (0x0000) - MASTER/SLAVE DSP UPGRADE SWITCH (00 MASTER DSP UPGRADE, 01 SLAVE DSP UPGRADE)
Register: 03040 Value: 00000007 (0x0007) - WORKING MODE (00=NO RESPONSE MODE, 01=VOLT-WATT DEFAULT, 02=VOLT-VAR, 03=FIXED POWER FACTOR, 04=FIX REACTIVE POWER, 05=POWER PF, 06=RULE21 VOLT-WATT)
Register: 03041 Value: 00000219 (0x00db) - INVERTER TEMPERATURE (0.1 CELSIUS)
Register: 03042 Value: 00006002 (0x1772) - GRID AC FREQUENCY (0.01 HZ)
Register: 03043 Value: 00000003 (0x0003) - STATUS (0-2 INIT, 3 READY OR ALERT)
Register: 03044 Value: 00000000 (0x0000) - LIMIT REACTIVE POWER ADJUSTMENT RATED POWER (1 W)
Register: 03045 Value: 00000000 (0x0000) - LIMIT REACTIVE POWER ADJUSTMENT RATED POWER (1 W)
Register: 03046 Value: 00000000 (0x0000) - LIMITED POWER ACTUAL VALUE (1 Var)
Register: 03047 Value: 00000000 (0x0000) - LIMITED POWER ACTUAL VALUE (1 Var)
Register: 03048 Value: 00000000 (0x0000) - INVERTER CONTROL WORD, 15K BELOW NO FUNCTION
Register: 03049 Value: 00011000 (0x2af8) - POWER LIMIT ACTUAL VALUE (1%)
Register: 03050 Value: 00001000 (0x03e8) - ACTUAL ADJUST VALUE OF POWER FACTOR (0.01)
Register: 03051 Value: 00001000 (0x03e8) - ACTUAL ADJUST VALUE OF POWER FACTOR (0.01)
Register: 03052 Value: 00000000 (0x0000) - REACTIVE POWER LIMITATION (1%)
Register: 03053 Value: 00000045 (0x002d) - COUNTRY STANDARD CODE
Register: 03054 Value: 00000004 (0x0004) - POWER CURVE CODE (crossed out)
Register: 03055 Value: 00000000 (0x0000) - REACTIVE POWER (1 Var)
Register: 03056 Value: 00000000 (0x0000) - REACTIVE POWER (1 Var)
Register: 03057 Value: 00000000 (0x0000) - APPARENT POWER (AC APPARENT POWER) (1 VA)
Register: 03058 Value: 00001740 (0x06cc) - APPARENT POWER (AC APPARENT POWER) (1 VA)
Register: 03059 Value: 00001000 (0x03e8) - NOT LISTED
Register: 03060 Value: 00000000 (0x0000) - INVERTER SERIAL NUMBER
Register: 03061 Value: 00000000 (0x0000) - INVERTER SERIAL NUMBER 2
Register: 03062 Value: 00000000 (0x0000) - INVERTER SERIAL NUMBER 3
Register: 03063 Value: 00000000 (0x0000) - INVERTER SERIAL NUMBER 4
Register: 03064 Value: 00000000 (0x0000) - RESERVED
Register: 03065 Value: 00000002 (0x0002) - SETTING FLAG
Register: 03066 Value: 00000000 (0x0000) - FAULT CODE 01
Register: 03067 Value: 00000000 (0x0000) - FAULT CODE 02
Register: 03068 Value: 00000000 (0x0000) - FAULT CODE 03
Register: 03069 Value: 00000000 (0x0000) - FAULT CODE 04
Register: 03070 Value: 00000000 (0x0000) - FAULT CODE 05
Register: 03071 Value: 00000001 (0x0001) - WORKING STATUS
Register: 03072 Value: 00000023 (0x0017) - CLOCK YEAR
Register: 03073 Value: 00000003 (0x0003) - CLOCK MONTH
Register: 03074 Value: 00000026 (0x001a) - CLOCK DAY
Register: 03075 Value: 00000015 (0x000f) - CLOCK HOUR (24H)
Register: 03076 Value: 00000056 (0x0038) - CLOCK MINUTE
Register: 03077 Value: 00000021 (0x0015) - CLOCK SECOND
Register: 03078 Value: 00000000 (0x0000) - RESERVED
Register: 03079 Value: 00000000 (0x0000) - METER GENERATION (1 Wh)
Register: 03080 Value: 00000000 (0x0000) - METER GENERATION (1 Wh)
Register: 03081 Value: 00000000 (0x0000) - METER VOLTAGE (1 V)
Register: 03082 Value: 00000000 (0x0000) - METER CURRENT (1 A)
Register: 03083 Value: 00000000 (0x0000) - METER ACTIVE POWER (1 W)
Register: 03084 Value: 00000000 (0x0000) - METER ACTIVE POWER (1 W)
Register: 03085 Value: 00000240 (0x00f0) - LEAKED CURRENT THRESHOLD (1 mA)