Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

not producing / producing 0.5.17 #246

Closed
Pony1966 opened this issue Sep 5, 2022 · 5 comments
Closed

not producing / producing 0.5.17 #246

Pony1966 opened this issue Sep 5, 2022 · 5 comments
Labels
bug Something isn't working duplicate This issue or pull request already exists fixed dev fixed

Comments

@Pony1966
Copy link

Pony1966 commented Sep 5, 2022

Die Anzeige springt zwischen producing und not producing hin und her.
Mqtt Datenpunkte werden im Mqtt Broker nicht mehr erstellt.
Ein Wechsel zwischen No Limit und Absolut in Watt non Persistent zeigt keine Veränderung.
Payload unterschiedlicher Länge sind per hterm zu sehen.
Wemos D1, HM600, Soft 0ae56ef

@aschiffler
Copy link
Contributor

Bitte mal ca. 20 Sekunden serial log dazu posten.

@aschiffler aschiffler added bug Something isn't working ESP ESP8266 / ESP32 related labels Sep 5, 2022
@Pony1966
Copy link
Author

Pony1966 commented Sep 5, 2022

Log

I: connect to network '500' ...<\r><\n>
...........<\r><\n>
........................................<\r><\n>
........................................<\r><\n>
....................................<\r><\n>
I: <\n><\n>----------------------------------------<\r><\n>
I: Welcome to AHOY!<\r><\n>
I: <\n>point your browser to http://192.168.2.00<\r><\n>
I: to configure your device<\r><\n>
I: ----------------------------------------<\n><\r><\n>
I: RF24 Amp Pwr: RF24_PA_I: HIGH<\r><\n>
I: Radio Config:<\r><\n>
SPI Frequency<9><9>= 1 Mhz<\n>Channel<9><9><9>= 3 (~ 2403 MHz)<\r><\n>
Model<9><9><9>= nRF24L01+<\r><\n>
RF Data Rate<9><9>= 250 KBPS<\r><\n>
RF Power Amplifier<9>= PA_HIGH<\r><\n>
RF Low Noise Amplifier<9>= Enabled<\r><\n>
CRC Length<9><9>= 16 bits<\r><\n>
Address Length<9><9>= 5 bytes<\r><\n>
Static Payload Length<9>= 32 bytes<\r><\n>
Auto Retry Delay<9>= 250 microseconds<\r><\n>
Auto Retry Attempts<9>= 0 maximum<\r><\n>
Packets lost on<\n>    current channel<9>= 0<\r><\n>
Retry attempts made for<\n>    last transmission<9>= 0<\r><\n>
Multicast<9><9>= Disabled<\r><\n>
Custom ACK Payload<9>= Disabled<\r><\n>
Dynamic Payloads<9>= Enabled<\r><\n>
Auto Acknowledgment<9>= Disabled<\r><\n>
Primary Mode<9><9>= RX<\r><\n>
TX address<9><9>= 0xe7e7e7e7e7<\r><\n>
pipe 0 (closed) bound<9>= 0xe7e7e7e7e7<\r><\n>
pipe 1 ( open ) bound<9>= 0x1234567801<\r><\n>
pipe 2 (closed) bound<9>= 0xc3<\r><\n>
pipe 3 (closed) bound<9>= 0xc4<\r><\n>
pipe 4 (closed) bound<9>= 0xc5<\r><\n>
pipe 5 (closed) bound<9>= 0xc6<\r><\n>
I: [NTP]: 2022-09-05 18:44:28<\r><\n>
I: enqueued cmd failed/timeout<\r><\n>
I: Inverter #0 I: no Payload received! (retransmits: 0)<\r><\n>
I: Requesting Inverter SN 114181867721<\r><\n>
I: RX 27B Ch23 | 95 81 86 77 21 81 86 77 21 81 27 1A 07 E5 04 4D 03 4A 00 68 00 00 00 00 E6 FB BE <\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 01 00 01 00 F2 00 28 00 62 01 F4 00 33 01 00 00 00 EA <\r><\n>
I: RX 23B Ch3 | 95 81 86 77 21 81 86 77 21 83 00 00 00 0E 03 E8 01 29 24 8B 2C 68 30 <\r><\n>
E: while retrieving data: Frame 2 missing: Request Retransmit<\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 02 5D 90 00 00 17 DA 07 6F 11 4C 09 32 13 85 01 52 5C <\r><\n>
I: RX 27B Ch23 | 95 81 86 77 21 81 86 77 21 02 5D 90 00 00 17 DA 07 6F 11 4C 09 32 13 85 01 52 5C <\r><\n>
I: Payload (42): 00 01 00 F2 00 28 00 62 01 F4 00 33 01 00 00 00 5D 90 00 00 17 DA 07 6F 11 4C 09 32 13 85 01 52 00 00 00 0E 03 E8 01 29 24 8B <\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch0/FWVersion: 1.000 <\r><\n>
I: myInv0/ch0/FWBuildYear: 242.000 <\r><\n>
I: myInv0/ch0/FWBuildMonthDay: 40.000 <\r><\n>
I: myInv0/ch0/HWPartId: 500.000 <\r><\n>
I: <\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch0/FWVersion: 1.000 <\r><\n>
I: myInv0/ch0/FWBuildYear: 242.000 <\r><\n>
I: myInv0/ch0/FWBuildMonthDay: 40.000 <\r><\n>
I: myInv0/ch0/HWPartId: 500.000 <\r><\n>
I: <\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch0/FWVersion: 1.000 <\r><\n>
I: myInv0/ch0/FWBuildYear: 242.000 <\r><\n>
I: myInv0/ch0/FWBuildMonthDay: 40.000 <\r><\n>
I: myInv0/ch0/HWPartId: 500.000 <\r><\n>
I: <\r><\n>
I: Requesting Inverter SN 114181867721<\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 81 00 01 00 53 00 00 03 E8 FF FF FF FF 01 68 9F 8F D4 <\r><\n>
I: RX 27B Ch23 | 95 81 86 77 21 81 86 77 21 81 00 01 00 53 00 00 03 E8 FF FF FF FF 01 68 9F 8F D4 <\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 01 00 01 00 E7 00 2A 00 61 01 F4 00 33 01 00 00 00 FE <\r><\n>
I: RX 27B Ch23 | 95 81 86 77 21 81 86 77 21 01 00 01 00 E7 00 2A 00 61 01 F4 00 33 01 00 00 00 FE <\r><\n>
I: RX 23B Ch3 | 95 81 86 77 21 81 86 77 21 83 00 00 00 0E 03 E8 01 29 24 8D 56 1D 39 <\r><\n>
E: while retrieving data: Frame 2 missing: Request Retransmit<\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 02 5D 90 00 00 17 DA 07 6F 11 4C 09 32 13 85 01 51 5F <\r><\n>
I: RX 27B Ch23 | 95 81 86 77 21 81 86 77 21 02 5D 90 00 00 17 DA 07 6F 11 4C 09 32 13 85 01 51 5F <\r><\n>
I: Payload (42): 00 01 00 E7 00 2A 00 61 01 F4 00 33 01 00 00 00 5D 90 00 00 17 DA 07 6F 11 4C 09 32 13 85 01 51 00 00 00 0E 03 E8 01 29 24 8D <\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch0/PowerLimit: 23.100 %<\r><\n>
I: <\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch0/PowerLimit: 23.100 %<\r><\n>
I: <\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch0/PowerLimit: 23.100 %<\r><\n>
I: <\r><\n>
I: Requesting Inverter SN 114181867721<\r><\n>
I: enqueuedCmd: 11<\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 01 00 01 00 EA 00 2A 00 62 01 F4 00 33 01 00 00 00 F0 <\r><\n>
I: RX 27B Ch23 | 95 81 86 77 21 81 86 77 21 01 00 01 00 EA 00 2A 00 62 01 F4 00 33 01 00 00 00 F0 <\r><\n>
I: RX 23B Ch3 | 95 81 86 77 21 81 86 77 21 83 00 00 00 0E 03 E8 01 29 24 8E AE C7 18 <\r><\n>
I: RX 23B Ch23 | 95 81 86 77 21 81 86 77 21 83 00 00 00 0E 03 E8 01 29 24 8E AE C7 18 <\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 01 00 01 00 EA 00 2A 00 62 01 F4 00 33 01 00 00 00 F0 <\r><\n>
I: RX 27B Ch23 | 95 81 86 77 21 81 86 77 21 01 00 01 00 EA 00 2A 00 62 01 F4 00 33 01 00 00 00 F0 <\r><\n>
I: RX 23B Ch3 | 95 81 86 77 21 81 86 77 21 83 00 00 00 0E 03 E8 01 29 24 8F 6E 06 18 <\r><\n>
I: RX 23B Ch23 | 95 81 86 77 21 81 86 77 21 83 00 00 00 0E 03 E8 01 29 24 8F 6E 06 18 <\r><\n>
E: while retrieving data: Frame 2 missing: Request Retransmit<\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 02 5D 90 00 00 17 DB 07 6F 11 4D 09 33 13 85 01 52 5D <\r><\n>
I: RX 27B Ch23 | 95 81 86 77 21 81 86 77 21 02 5D 90 00 00 17 DB 07 6F 11 4D 09 33 13 85 01 52 5D <\r><\n>
I: Payload (42): 00 01 00 EA 00 2A 00 62 01 F4 00 33 01 00 00 00 5D 90 00 00 17 DB 07 6F 11 4D 09 33 13 85 01 52 00 00 00 0E 03 E8 01 29 24 8F <\r><\n>
I: enqueuedCmd: 17<\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch1/U_DC: 23.400 V<\r><\n>
I: myInv0/ch1/I_DC: 0.420 A<\r><\n>
I: myInv0/ch1/P_DC: 9.800 W<\r><\n>
I: myInv0/ch1/YieldDay: 1903.000 <\r><\n>
I: myInv0/ch1/YieldTotal: 23.952 kW<\r><\n>
I: myInv0/ch1/Irradiation: 2.882 %<\r><\n>
I: myInv0/ch2/U_DC: 50.000 V<\r><\n>
I: myInv0/ch2/I_DC: 0.510 A<\r><\n>
I: myInv0/ch2/P_DC: 25.600 W<\r><\n>
I: myInv0/ch2/YieldDay: 4429.000 <\r><\n>
I: myInv0/ch2/YieldTotal: 6.107 kWh<\r><\n>
I: myInv0/ch2/Irradiation: 7.529 %<\r><\n>
I: myInv0/ch0/U_AC: 235.500 V<\r><\n>
I: myInv0/ch0/I_AC: 0.140 A<\r><\n>
I: myInv0/ch0/P_AC: 33.800 W<\r><\n>
I: myInv0/ch0/Freq: 49.970 Hz<\r><\n>
I: myInv0/ch0/Temp: 29.700 °<\r><\n>
I: myInv0/ch0/ALARM_MES_ID: 9359.000 <\r><\n>
I: myInv0/ch0/YieldDay: 6332.000 <\r><\n>
I: myInv0/ch0/YieldTotal: 30.059 kW<\r><\n>
I: myInv0/ch0/P_DC: 35.400 W<\r><\n>
I: myInv0/ch0/Efficiency: 95.480 %<\r><\n>
I: <\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch1/U_DC: 23.400 V<\r><\n>
I: myInv0/ch1/I_DC: 0.420 A<\r><\n>
I: myInv0/ch1/P_DC: 9.800 W<\r><\n>
I: myInv0/ch1/YieldDay: 1903.000 <\r><\n>
I: myInv0/ch1/YieldTotal: 23.952 kW<\r><\n>
I: myInv0/ch1/Irradiation: 2.882 %<\r><\n>
I: myInv0/ch2/U_DC: 50.000 V<\r><\n>
I: myInv0/ch2/I_DC: 0.510 A<\r><\n>
I: myInv0/ch2/P_DC: 25.600 W<\r><\n>
I: myInv0/ch2/YieldDay: 4429.000 <\r><\n>
I: myInv0/ch2/YieldTotal: 6.107 kWh<\r><\n>
I: myInv0/ch2/Irradiation: 7.529 %<\r><\n>
I: myInv0/ch0/U_AC: 235.500 V<\r><\n>
I: myInv0/ch0/I_AC: 0.140 A<\r><\n>
I: myInv0/ch0/P_AC: 33.800 W<\r><\n>
I: myInv0/ch0/Freq: 49.970 Hz<\r><\n>
I: myInv0/ch0/Temp: 29.700 °<\r><\n>
I: myInv0/ch0/ALARM_MES_ID: 9359.000 <\r><\n>
I: myInv0/ch0/YieldDay: 6332.000 <\r><\n>
I: myInv0/ch0/YieldTotal: 30.059 kW<\r><\n>
I: myInv0/ch0/P_DC: 35.400 W<\r><\n>
I: myInv0/ch0/Efficiency: 95.480 %<\r><\n>
I: <\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch1/U_DC: 23.400 V<\r><\n>
I: myInv0/ch1/I_DC: 0.420 A<\r><\n>
I: myInv0/ch1/P_DC: 9.800 W<\r><\n>
I: myInv0/ch1/YieldDay: 1903.000 <\r><\n>
I: myInv0/ch1/YieldTotal: 23.952 kW<\r><\n>
I: myInv0/ch1/Irradiation: 2.882 %<\r><\n>
I: myInv0/ch2/U_DC: 50.000 V<\r><\n>
I: myInv0/ch2/I_DC: 0.510 A<\r><\n>
I: myInv0/ch2/P_DC: 25.600 W<\r><\n>
I: myInv0/ch2/YieldDay: 4429.000 <\r><\n>
I: myInv0/ch2/YieldTotal: 6.107 kWh<\r><\n>
I: myInv0/ch2/Irradiation: 7.529 %<\r><\n>
I: myInv0/ch0/U_AC: 235.500 V<\r><\n>
I: myInv0/ch0/I_AC: 0.140 A<\r><\n>
I: myInv0/ch0/P_AC: 33.800 W<\r><\n>
I: myInv0/ch0/Freq: 49.970 Hz<\r><\n>
I: myInv0/ch0/Temp: 29.700 °<\r><\n>
I: myInv0/ch0/ALARM_MES_ID: 9359.000 <\r><\n>
I: myInv0/ch0/YieldDay: 6332.000 <\r><\n>
I: myInv0/ch0/YieldTotal: 30.059 kW<\r><\n>
I: myInv0/ch0/P_DC: 35.400 W<\r><\n>
I: myInv0/ch0/Efficiency: 95.480 %<\r><\n>
I: <\r><\n>
I: Requesting Inverter SN 114181867721<\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 81 00 01 B0 02 24 90 5F 00 5F 00 FF FF CA 84 8B 13 C5 <\r><\n>
I: RX 27B Ch23 | 95 81 86 77 21 81 86 77 21 81 00 01 B0 02 24 90 5F 00 5F 00 FF FF CA 84 8B 13 C5 <\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 01 00 01 00 EE 00 29 00 62 01 F5 00 32 00 FA 00 00 0C <\r><\n>
I: RX 23B Ch3 | 95 81 86 77 21 81 86 77 21 83 00 00 00 0E 03 E8 01 29 24 91 9B 5F AA <\r><\n>
E: while retrieving data: Frame 2 missing: Request Retransmit<\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 02 5D 90 00 00 17 DB 07 6F 11 4D 09 32 13 85 01 4D 43 <\r><\n>
I: RX 27B Ch23 | 95 81 86 77 21 81 86 77 21 02 5D 90 00 00 17 DB 07 6F 11 4D 09 32 13 85 01 4D 43 <\r><\n>
I: Payload (42): 00 01 00 EE 00 29 00 62 01 F5 00 32 00 FA 00 00 5D 90 00 00 17 DB 07 6F 11 4D 09 32 13 85 01 4D 00 00 00 0E 03 E8 01 29 24 91 <\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch0/LastAlarmCode: 1.000 <\r><\n>
I: <\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch0/LastAlarmCode: 1.000 <\r><\n>
I: <\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch0/LastAlarmCode: 1.000 <\r><\n>
I: <\r><\n>
I: Requesting Inverter SN 114181867721<\r><\n>
I: enqueuedCmd: 11<\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 01 00 01 00 EF 00 29 00 62 01 F5 00 30 00 F1 00 00 04 <\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 01 00 01 00 EF 00 29 00 62 01 F5 00 30 00 F1 00 00 04 <\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 02 5D 90 00 00 17 DB 07 6F 11 4D 09 31 13 86 01 44 4A <\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 01 00 01 00 EF 00 29 00 62 01 F5 00 30 00 F1 00 00 04 <\r><\n>
I: RX 27B Ch3 | 95 81 86 77 21 81 86 77 21 02 5D 90 00 00 17 DB 07 6F 11 4D 09 31 13 86 01 44 4A <\r><\n>
E: while retrieving data: last frame missing: Request Retransmit<\r><\n>
I: RX 23B Ch3 | 95 81 86 77 21 81 86 77 21 83 00 00 00 0E 03 E8 01 29 24 93 65 DF D6 <\r><\n>
I: RX 23B Ch23 | 95 81 86 77 21 81 86 77 21 83 00 00 00 0E 03 E8 01 29 24 93 65 DF D6 <\r><\n>
I: Payload (42): 00 01 00 EF 00 29 00 62 01 F5 00 30 00 F1 00 00 5D 90 00 00 17 DB 07 6F 11 4D 09 31 13 86 01 44 00 00 00 0E 03 E8 01 29 24 93 <\r><\n>
I: enqueuedCmd: 17<\r><\n>
I: Inverter: 0<\r><\n>
I: myInv0/ch1/U_DC: 23.900 V<\r><\n>
I: myInv0/ch1/I_DC: 0.410 A<\r><\n>
I: myInv0/ch1/P_DC: 9.800 W<\r><\n>
I: myInv0/ch1/YieldDay: 1903.000 <\r><\n>
I: myInv0/ch1/YieldTotal: 23.952 kW<\r><\n>
I: myInv0/ch1/Irradiation: 2.882 %<\r><\n>
I: myInv0/ch2/U_DC: 50.100 V<\r><\n>
I: myInv0/ch2/I_DC: 0.480 A<\r><\n>
I: myInv0/ch2/P_DC: 24.100 W<\r><\n>
I: myInv0/ch2/YieldDay: 4429.000 <\r><\n>
I: myInv0/ch2/YieldTotal: 6.107 kWh<\r><\n>
I: myInv0/ch2/Irradiation: 7.088 %<\r><\n>
I: myInv0/ch0/U_AC: 235.300 V<\r><\n>
I: myInv0/ch0/I_AC: 0.140 A<\r><\n>
I: myInv0/ch0/P_AC: 32.400 W<\r><\n>
I: myInv0/ch0/Freq: 49.980 Hz<\r><\n>
I: myInv0/ch0/Temp: 29.700 °<\r><\n>
I: myInv0/ch0/ALARM_MES_ID: 9363.000 <\r><\n>
I: myInv0/ch0/YieldDay: 6332.000 <\r><\n>
I: myInv0/ch0/YieldTotal: 30.059 kW<\r><\n>
I: myInv0/ch0/P_DC: 33.900 W<\r><\n>
I: myInv0/ch0/Efficiency: 95.575 %<\r><\n>
I: <\r><\n>

Edit (lumapu): code format

@Pony1966
Copy link
Author

Pony1966 commented Sep 5, 2022

not Producing wenn 2 Alarm Code kommt.

s  log 1

@DirkausHH
Copy link

Bei meinem HM-300 und 0.5.17 passiert das nicht.

@aschiffler
Copy link
Contributor

Ok. Der Code oben ist ab reboot/start von ahoy. Hier kommt es bedingt durch die Abfrage von Firmware / Alarm Code zu Zuständen die nicht eindeutig sind.
Siehe dazu die Doku hier: https://github.com/grindylow/ahoy/blob/main/tools/esp8266/User_Manual.md#developer-information-about-command-queue
Es sollte aber nachdem "nur noch" das enqueuedCmd: 11 kommt funktionieren.
Im aktuellen Release müsste das so funktionieren.

Bitte nochmals berichten / testen und ggf. issue wieder öffnen

@stefan123t stefan123t added implemented implemented in development duplicate This issue or pull request already exists labels Sep 7, 2022
@stefan123t stefan123t added fixed dev fixed and removed ESP ESP8266 / ESP32 related implemented implemented in development labels Jan 12, 2023
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
bug Something isn't working duplicate This issue or pull request already exists fixed dev fixed
Projects
None yet
Development

No branches or pull requests

4 participants