Notifications
You must be signed in to change notification settings - Fork 47
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
how fast do we expect things to start? #296
Comments
Now with today snapshot https://github.com/rusefi/wideband/releases/tag/20231122-2 60 seconds to report AFR. is it a coincidence that I had to touch throttle to get reading? Can wideband detect "too lean" and "too rich" and report those as separate states? |
@rusefillc give it another try with current master |
nope, that's just a coincidence.
It could detect that the pump drive is pinned against the stop (and so the nernst voltage isn't being controlled at ~0.45v), we could at least clear the valid bit when that happens. |
progress! we now get AFR in about 20 seconds from engine start |
this is detected and transmitted in ea46db5 |
hellen 042
first release
not first start today - exhaust and sensor are not completely cold
yet it seems to take ~45 seconds to see WBO reasing
(also all that time fault code is just 0 maybe I shall migrate to fresh binary)
2023-11-22_14.52.35 with sensor.mlg.zip
The text was updated successfully, but these errors were encountered: