Training a silicon MLFF with nequip shows reasonable force error but high energy MAEs. A colab notebook is kept here . Any thoughts on what could be going wrong in terms of setting config parameters etc.?

@knc6 knc6 added the question Further information is requested label Feb 7, 2024
@cw-tan
Copy link
Collaborator

cw-tan commented Jun 26, 2024

Hi @knc6,

Thank you for your interest in using NequIP and apologies for the delay! Maybe you've figured it out by now, but it appears that the config file you're using only includes forces in the loss function, i.e.

# loss function
loss_coeffs: forces

You can also include energies in the loss function as follows

# loss function
loss_coeffs:                                                                        
  forces: 1
  total_energy:                                                                    
    - 1
    - PerAtomMSELoss

For example, see this example.yaml.