-
Notifications
You must be signed in to change notification settings - Fork 20
/
semp-tcp.py
executable file
·271 lines (237 loc) · 14.6 KB
/
semp-tcp.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
#!/usr/bin/env python3
import argparse
import configparser
import importlib
import logging
import sys
import threading
import time
from pymodbus.server import StartTcpServer
from pymodbus.constants import Endian
from pymodbus.device import ModbusDeviceIdentification
from pymodbus.transaction import ModbusSocketFramer
from pymodbus.transaction import ModbusRtuFramer
from pymodbus.datastore import ModbusSlaveContext
from pymodbus.datastore import ModbusServerContext
from pymodbus.payload import BinaryPayloadBuilder
def t_update(ctx, stop, module, device, refresh):
this_t = threading.currentThread()
logger = logging.getLogger()
while not stop.is_set():
try:
values = module.values(device)
if not values:
logger.debug(f"{this_t.name}: no new values")
continue
block_1001 = BinaryPayloadBuilder(byteorder=Endian.Big, wordorder=Endian.Little)
block_1001.add_32bit_float(values.get("energy_active", 0)) # total active energy
block_1001.add_32bit_float(values.get("import_energy_active", 0)) # imported active energy
block_1001.add_32bit_float(values.get("energy_active", 0)) # total active energy non-reset
block_1001.add_32bit_float(values.get("import_energy_active", 0)) # imported active energy non-reset
block_1001.add_32bit_float(values.get("power_active", 0)) # total power
block_1001.add_32bit_float(values.get("l1_power_active", 0)) # power l1
block_1001.add_32bit_float(values.get("l2_power_active", 0)) # power l2
block_1001.add_32bit_float(values.get("l3_power_active", 0)) # power l3
block_1001.add_32bit_float(values.get("voltage_ln", 0)) # l-n voltage
block_1001.add_32bit_float(values.get("l1n_voltage", 0)) # l1-n voltage
block_1001.add_32bit_float(values.get("l2n_voltage", 0)) # l2-n voltage
block_1001.add_32bit_float(values.get("l3n_voltage", 0)) # l3-n voltage
block_1001.add_32bit_float(values.get("voltage_ll", 0)) # l-l voltage
block_1001.add_32bit_float(values.get("l12_voltage", 0)) # l1-l2 voltage
block_1001.add_32bit_float(values.get("l23_voltage", 0)) # l2-l3 voltage
block_1001.add_32bit_float(values.get("l31_voltage", 0)) # l3-l1 voltage
block_1001.add_32bit_float(values.get("frequency", 0)) # line frequency
ctx.setValues(3, 1000, block_1001.to_registers())
block_1101 = BinaryPayloadBuilder(byteorder=Endian.Big, wordorder=Endian.Little)
block_1101.add_32bit_float(values.get("l1_energy_active", 0)) # total active energy l1
block_1101.add_32bit_float(values.get("l2_energy_active", 0)) # total active energy l2
block_1101.add_32bit_float(values.get("l3_energy_active", 0)) # total active energy l3
block_1101.add_32bit_float(values.get("l1_import_energy_active", 0)) # imported active energy l1
block_1101.add_32bit_float(values.get("l2_import_energy_active", 0)) # imported active energy l2
block_1101.add_32bit_float(values.get("l3_import_energy_active", 0)) # imported active energy l3
block_1101.add_32bit_float(values.get("export_energy_active", 0)) # total exported active energy
block_1101.add_32bit_float(values.get("export_energy_active", 0)) # total exported active energy non-reset
block_1101.add_32bit_float(values.get("l1_export_energy_active", 0)) # exported energy l1
block_1101.add_32bit_float(values.get("l2_export_energy_active", 0)) # exported energy l2
block_1101.add_32bit_float(values.get("l3_export_energy_active", 0)) # exported energy l3
block_1101.add_32bit_float(values.get("energy_reactive", 0)) # total reactive energy
block_1101.add_32bit_float(values.get("l1_energy_reactive", 0)) # reactive energy l1
block_1101.add_32bit_float(values.get("l2_energy_reactive", 0)) # reactive energy l2
block_1101.add_32bit_float(values.get("l3_energy_reactive", 0)) # reactive energy l3
block_1101.add_32bit_float(values.get("energy_apparent", 0)) # total apparent energy
block_1101.add_32bit_float(values.get("l1_energy_apparent", 0)) # apparent energy l1
block_1101.add_32bit_float(values.get("l2_energy_apparent", 0)) # apparent energy l2
block_1101.add_32bit_float(values.get("l3_energy_apparent", 0)) # apparent energy l3
block_1101.add_32bit_float(values.get("power_factor", 0)) # power factor
block_1101.add_32bit_float(values.get("l1_power_factor", 0)) # power factor l1
block_1101.add_32bit_float(values.get("l2_power_factor", 0)) # power factor l2
block_1101.add_32bit_float(values.get("l3_power_factor", 0)) # power factor l3
block_1101.add_32bit_float(values.get("power_reactive", 0)) # total reactive power
block_1101.add_32bit_float(values.get("l1_power_reactive", 0)) # reactive power l1
block_1101.add_32bit_float(values.get("l2_power_reactive", 0)) # reactive power l2
block_1101.add_32bit_float(values.get("l3_power_reactive", 0)) # reactive power l3
block_1101.add_32bit_float(values.get("power_apparent", 0)) # total apparent power
block_1101.add_32bit_float(values.get("l1_power_apparent", 0)) # apparent power l1
block_1101.add_32bit_float(values.get("l2_power_apparent", 0)) # apparent power l2
block_1101.add_32bit_float(values.get("l3_power_apparent", 0)) # apparent power l3
block_1101.add_32bit_float(values.get("l1_current", 0)) # current l1
block_1101.add_32bit_float(values.get("l2_current", 0)) # current l2
block_1101.add_32bit_float(values.get("l3_current", 0)) # current l3
block_1101.add_32bit_float(values.get("demand_power_active", 0)) # demand power
block_1101.add_32bit_float(values.get("minimum_demand_power_active", 0)) # minimum demand power
block_1101.add_32bit_float(values.get("maximum_demand_power_active", 0)) # maximum demand power
block_1101.add_32bit_float(values.get("demand_power_apparent", 0)) # apparent demand power
block_1101.add_32bit_float(values.get("l1_demand_power_active", 0)) # demand power l1
block_1101.add_32bit_float(values.get("l2_demand_power_active", 0)) # demand power l2
block_1101.add_32bit_float(values.get("l3_demand_power_active", 0)) # demand power l3
ctx.setValues(3, 1100, block_1101.to_registers())
except Exception as e:
logger.critical(f"{this_t.name}: {e}")
finally:
time.sleep(refresh)
if __name__ == "__main__":
argparser = argparse.ArgumentParser()
argparser.add_argument("-c", "--config", type=str, default="semp-tcp.conf")
argparser.add_argument("-v", "--verbose", action="store_true", default=False)
args = argparser.parse_args()
default_config = {
"server": {
"address": "0.0.0.0",
"port": 5502,
"framer": "socket",
"log_level": "INFO",
"meters": ''
},
"meters": {
"dst_address": 2,
"type": "generic",
"ct_current": 5,
"ct_inverted": 0,
"phase_offset": 120,
"serial_number": 987654,
"refresh_rate": 5
}
}
confparser = configparser.ConfigParser()
confparser.read(args.config)
if not confparser.has_section("server"):
confparser["server"] = default_config["server"]
log_handler = logging.StreamHandler(sys.stdout)
log_handler.setFormatter(logging.Formatter("%(asctime)s %(levelname)s: %(message)s", datefmt="%Y-%m-%d %H:%M:%S"))
logger = logging.getLogger()
logger.setLevel(getattr(logging, confparser["server"].get("log_level", fallback=default_config["server"]["log_level"]).upper()))
logger.addHandler(log_handler)
if args.verbose:
logger.setLevel(logging.DEBUG)
slaves = {}
threads = []
thread_stops = []
try:
if confparser.has_option("server", "meters"):
meters = [m.strip() for m in confparser["server"].get("meters", fallback=default_config["server"]["meters"]).split(',')]
for meter in meters:
address = confparser[meter].getint("dst_address", fallback=default_config["meters"]["dst_address"])
meter_type = confparser[meter].get("type", fallback=default_config["meters"]["type"])
meter_module = importlib.import_module(f"devices.{meter_type}")
meter_device = meter_module.device(confparser[meter])
slave_ctx = ModbusSlaveContext()
block_1601 = BinaryPayloadBuilder(byteorder=Endian.Big, wordorder=Endian.Little)
block_1601.add_32bit_int(1234) # config passcode
block_1601.add_16bit_int(confparser[meter].getint("ct_current", fallback=default_config["meters"]["ct_current"])) # ct rated current
block_1601.add_16bit_int(confparser[meter].getint("ct_current", fallback=default_config["meters"]["ct_current"])) # ct rated current l1
block_1601.add_16bit_int(confparser[meter].getint("ct_current", fallback=default_config["meters"]["ct_current"])) # ct rated current l2
block_1601.add_16bit_int(confparser[meter].getint("ct_current", fallback=default_config["meters"]["ct_current"])) # ct rated current l3
block_1601.add_16bit_int(confparser[meter].getint("ct_inverted", fallback=default_config["meters"]["ct_inverted"])) # ct direction inversion
block_1601.add_16bit_int(0) # measurement averaging
block_1601.add_16bit_int(0) # power scale
block_1601.add_16bit_int(15) # demand period
block_1601.add_16bit_int(1) # demand subintervals
block_1601.add_16bit_int(10000) # power/energy adjustment l1
block_1601.add_16bit_int(10000) # power/energy adjustment l2
block_1601.add_16bit_int(10000) # power/energy adjustment l3
block_1601.add_16bit_int(-1000) # ct phase angle adjustment l1
block_1601.add_16bit_int(-1000) # ct phase angle adjustment l2
block_1601.add_16bit_int(-1000) # ct phase angle adjustment l3
block_1601.add_16bit_int(1500) # minimum power reading
block_1601.add_16bit_int(confparser[meter].getint("phase_offset", fallback=default_config["meters"]["phase_offset"])) # phase offset
block_1601.add_16bit_int(0) # reset energy
block_1601.add_16bit_int(0) # reset demand
block_1601.add_16bit_int(20000) # current scale
block_1601.add_16bit_int(0) # io pin mode
slave_ctx.setValues(3, 1600, block_1601.to_registers())
block_1651 = BinaryPayloadBuilder(byteorder=Endian.Big, wordorder=Endian.Little)
block_1651.add_16bit_int(0) # apply config
block_1651.add_16bit_int(address) # modbus address
block_1651.add_16bit_int(4) # baud rate
block_1651.add_16bit_int(0) # parity mode
block_1651.add_16bit_int(0) # modbus mode
block_1651.add_16bit_int(5) # message delay
slave_ctx.setValues(3, 1650, block_1651.to_registers())
block_1701 = BinaryPayloadBuilder(byteorder=Endian.Big, wordorder=Endian.Little)
block_1701.add_32bit_int(confparser[meter].getint("serial_number", fallback=default_config["meters"]["serial_number"])) # serial number
block_1701.add_32bit_int(0) # uptime (s)
block_1701.add_32bit_int(0) # total uptime (s)
block_1701.add_16bit_int(202) # wattnode model
block_1701.add_16bit_int(31) # firmware version
block_1701.add_16bit_int(0) # wattnode options
block_1701.add_16bit_int(0) # error status
block_1701.add_16bit_int(0) # power fail count
block_1701.add_16bit_int(0) # crc error count
block_1701.add_16bit_int(0) # frame error count
block_1701.add_16bit_int(0) # packet error count
block_1701.add_16bit_int(0) # overrun count
block_1701.add_16bit_int(0) # error status 1
block_1701.add_16bit_int(0) # error status 2
block_1701.add_16bit_int(0) # error status 3
block_1701.add_16bit_int(0) # error status 4
block_1701.add_16bit_int(0) # error status 5
block_1701.add_16bit_int(0) # error status 6
block_1701.add_16bit_int(0) # error status 7
block_1701.add_16bit_int(0) # error status 8
slave_ctx.setValues(3, 1700, block_1701.to_registers())
update_t_stop = threading.Event()
update_t = threading.Thread(
target=t_update,
name=f"t_update_{address}",
args=(
slave_ctx,
update_t_stop,
meter_module,
meter_device,
confparser[meter].getint("refresh_rate", fallback=default_config["meters"]["refresh_rate"])
)
)
threads.append(update_t)
thread_stops.append(update_t_stop)
slaves.update({address: slave_ctx})
logger.info(f"Created {update_t}: {meter} {meter_type} {meter_device}")
if not slaves:
logger.warning(f"No meters defined in {args.config}")
config_framer = confparser["server"].get("framer", fallback=default_config["server"]["framer"])
framer = False
if config_framer == "socket":
framer = ModbusSocketFramer
elif config_framer == "rtu":
framer = ModbusRtuFramer
identity = ModbusDeviceIdentification()
server_ctx = ModbusServerContext(slaves=slaves, single=False)
time.sleep(1)
for t in threads:
t.start()
logger.info(f"Starting {t}")
server = StartTcpServer(
context=server_ctx,
framer=framer,
identity=identity,
address=(
confparser["server"].get("address", fallback=default_config["server"]["address"]),
confparser["server"].getint("port", fallback=default_config["server"]["port"])
)
)
except KeyboardInterrupt:
pass
finally:
for t_stop in thread_stops:
t_stop.set()
for t in threads:
t.join()