Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Allow changing temperature setpoint for heat load calculation in PartialZone #1337

Open
jelgerjansen opened this issue Nov 7, 2023 · 0 comments
Assignees

Comments

@jelgerjansen
Copy link
Contributor

IDEAS.Buildings.Components.Interfaces.PartialZone calculates the design load for the zone as the sum of transmission losses QTra_design, infiltration losses QInf_design, and a term related to reheating after night setback QRH_design. QTra_design and QInf_design assume an indoor temperatuur of 21°C which cannot be changed. Since the room setpoint temperature differs between different rooms (e.g. living room vs bedroom), we might consider to add a temperature parameter for calculating the design heat load. This value should also be propagated to the different constructions connected to the zone, since the tranmission losses of every building component is calculated in those components.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

3 participants