v1.0.0

Breaking Changes

  • Name of package is now @openbci/cyton

v0.3.6

Bug Fixes

  • Fix bug where parseGanglion could result in a concat of non-buffer types

v0.3.5

Bug Fixes

  • Fix bug where getFirmware failed for patch or minor versions over 9 (aka double digits)

v0.3.4

Bug Fixes

  • Protect and ensure buffer returned for raw data packets

v0.3.3

Enhancements

  • Add raw of version to getFirmware
  • Bump mathjs to 4.0.0 to resolve insecurity

v0.3.1

Enhancements

  • Removed lodash from dependencies to reduce bundle size (thanks @alexcastillo!!)

v0.3.0

You can now use this module in the browser!! Huge should out to @alexcastillo for help with making with refactoring the project!

Breaking Changes

  • Removed simulator file back into cyton repo
  • Removed safe-buffer in place of buffer
  • Removed support for node version 5 and below
  • Utilities changed to to utilities
  • Constants is now constants
  • Inidividual functions can now be importated from the utilities module.

v0.2.7

Bug Fixes

  • No stopByte property for daisy samples. Added tests.

v0.2.6

Bug Fixes

  • Accel data with counts did not work for cyton with daisy over wifi.

v0.2.5

Bug Fixes

  • Had incorrect ganglion accel multiplication factor of 32mg per count but was really 16mg per count
  • newSample and newSampleNoScale in utility file did not have valid is true property.

v0.2.4

New Features

  • Add new constants for emitter

Bug Fixes

  • Fix bug where ganglion sample channel data when scale was false produced array of 8 values instead of 4

v0.2.3

New Features

  • Add function for parsing an impedance object .parsePacketImpedance()

v0.2.2

Bug Fixes

  • Fix wrap around bug in extractRawBLEDataPackets

v0.2.1

Bug Fixes

  • Accel data with counts did not work for cyton with daisy. Also fixed up some test errors with the effected functions.

New Features

  • Add features for openbci-ganglion

v0.2.0

New Feature

  • With scale option false, .parsePacketStandardAccel() .parsePacketTimeSyncedAccel() will now return array called will now return accelDataCounts property with un-scaled data.

v0.1.5

Bug Fixes

  • Was missing errors in constants used by ganglion and other ble projects.
  • Fixed getChannelData functions to support 2 channel cytons

v0.1.4

Bug Fixes

  • E-patch on new function added 0.1.3

v0.1.3

New Features

  • A bunch of functions to support synchronization of channel settings with cyton. Will be used by both the Wifi and the Cyton node modules.

v0.1.2

Bug Fixes

  • Send counts did not work for daisy.
  • Sample output was inconsistent
  • Fixed timeStamp to timestamp this was pr #147 (thanks @alexdevmotion)

v0.1.1

Bug Fixes

  • Send counts did not work for daisy.

v0.1.0

New Functions

  • Add function getFirmware(dataBuffer) to utilities

Breaking Changes

  • Removed function called findV2Firmware() because it's useless with v3.0.0 firmware

v0.0.10

New Function

  • Add boardTypeForNumberOfChannels() to Constants

v0.0.9

New Features

  • Add impedance calculation functions from cyton
  • The simulator from OpenBCI_NodeJS has been ripped out and place into this library! Woo.

v0.0.8

New Features

  • Sample object now has property valid of type boolean, false when error parseing packet, true otherwise. On false there will be another property called error of type string which contains an error message.

v0.0.7

Continuous Integration

  • Add npm run test-lint to add linting to travis.yml

Bug Fixes

  • Last sample number was confusing to use with transformRawDataPacketsToSample

New Features

  • In openBCIUtilities.js add function transformRawDataPacketToSample to parse a single raw data packet
  • In openBCIConstants.js add function rawDataToSampleObjectDefault(numChannels) which should be used by drivers to create the object that is passed through each call to transformRawDataPacketsToSample

v0.0.6

Bug Fixes

  • Could not use 'daisy' with sample rate setter.

New Features

  • Add function in utilities for making daisy packets.
  • Add code to getChannelDataArray for ganglion and daisy data being routed over wifi
  • Create idea of protocols i.e. BLE, Wifi, and Serial

Breaking changes

  • getChannelDataArray now takes object as only arg.

v0.0.5

Bug Fixes

  • When not scaling outputs channelDataCounts instead of channelData

v0.0.4

Bug Fixes

  • Fix bug where samples were not properly being extracted

v0.0.2

Breaking Changes

  • Renamed Sample to Utilities in index.js
  • Renamed openBCIUtilities.js to openBCIUtilities.js
  • Renamed openBCIUtilities-test.js to openBCIUtilities-test.js

New Features

  • Added a function in the sample module that parses a raw buffer of OpenBCI data, extracts raw data packets and returns the buffer with just the raw data packets removed. Allowing the user to process other data that is not a raw data.

v0.0.1

Initial release