Most lines in the configuration file contain one value. It's best to
put a slash (/
) after the required data on each line. Comments can
appear after the /
, as shown in the example below. Those items with
their description struck out are not available or ignored, either
because they are no longer needed or computed internally. Items
Line | Field | Type | Description |
---|---|---|---|
1 | 1 | string | Run title -- for user documentation only |
2 | 1 | flag | Enable hydrodynamics simulation |
3 | 1 | flag | Enable lateral inflow |
4 | 1 | flag | Enable TDG simulation |
5 | 1 | flag | Enable temperature simulation |
6 | 1 | flag | Enable detailed results print out |
7 | 1 | flag | Enable gage results output |
8 | 1 | flag | Enable profile results output |
2 | flag | Average gage and profile output over output time | |
9 | 1 | flag | Enable TDG dispersion |
10 | 1 | flag | Enable atmospheric TDG exchange (requires met data) |
11 | 1 | flag | Enable temperature dispersion |
12 | 1 | flag | Enable atmospheric energy exchange (requires met data) |
13 | 1 | flag | If true, read initial conditions from a hotstart file |
otherwise, read initial conditions file | |||
14 | 1 | flag | Write a hotstart file at the end of simulation |
15 | 1 | int | Units option: 0 = English, |
16 | 1 | int | Time option: |
17 | 1 | int | Units used for channel length in the point file: |
0 = feet, 1 = meters, 2 = miles, 3 = kilometers | |||
18 | 1 | int | Boundary condition at outlet: |
0 = stage, 1 = discharge | |||
19 | 1 | int | Maximum number of links (>= actual number of links) |
20 | 1 | int | Maximum number of points on a link |
21 | 1 | int | |
22 | 1 | int | Number of transport time sub-steps (0 = automatic) |
23 | 1 | flag | Enable debugging output |
24 | 1 | string | Link file name |
25 | 1 | string | Point file name |
26 | 1 | string | Section file name |
27 | 1 | string | Link BC file name |
28 | 1 | string | Initial conditions file name |
29 | 1 | string | Output file name |
30 | 1 | string | TDG BC file name |
31 | 1 | string | Temperature BC file name |
32 | 1 | string | Meteorologic zone table file name |
33 | 1 | string | Hydropower BC file name |
34 | 1 | string | TDG Coefficients file name |
35 | 1 | string | Restart file from which initial conditions are read |
36 | 1 | string | Hotstart file to write |
37 | 1 | string | Gage control file name |
38 | 1 | string | Profile control file name |
39 | 1 | string | Lateral inflow BC file name |
40 | 1 | string | Simulation start date (mm-dd-yyyy) |
41 | 1 | string | Simulation start time (HH:MM:SS) |
42 | 1 | string | Simulation end date (mm-dd-yyyy) |
43 | 1 | string | Simulation end time (HH:MM:SS) |
44 | 1 | real | Hydrodynamics time step |
2 | string | Optional time step units, one of: hr , min , day , and sec . hr is default. |
|
45 | 1 | int | Gage and profile output frequency (time steps) |
MASS1 Configuration File - Version 0.83
1 / Do Flow
0 / Do lateral inflow
0 / Do Gas
0 / Do Temp
0 / Do Printout
1 / Do Gage Printout
1 / Do Profile Printout
0 / Do Gas Dispersion
0 / Do Gas Air/Water Exchange
1 / Do Temp Dispersion
1 / Do Temp surface exchange
1 / Do Hotstart read file
0 / Do Restart write file
0 / Do Print section geometry
0 / Do write binary section geom
0 / Do read binary section geom
0 / units option
1 / time option
2 / time units
2 / channel length untis
0 / downstream bc type
5 / max links
400 / max points on a link
28 / max bc table
60000 / max times in a bc table
1379 / total number of x-sections
15 / number of transport sub time steps
0 / debug print flag
"../BaseFiles/prd2mcn.link" / link file name
"../BaseFiles/prd2mcn.point" / point file name nonuniform manning n
"../BaseFiles/CAN2MCN.dat" / section file name
"link-bc-files.dat" / linkBC file name
"initial.dat" / initial file name
"output.out" / output file name
"./transbc-files.dat" / gas transport file name
"temp-bc-files.dat" / temperature input
"weather-files.dat" / weather data files for each met_zone input
"./hydrobc-init.dat" / hydropower file name
"../Common_Files/tdg_coeff.dat" / TDG Coeff file name
"../Rampdown/restart.dat" / hotstart-warmup-unix.dat / read restart file name
"hotstart.dat" / Write restart file name
"../BaseFiles/gage-control.dat" / gage control file name
"../BaseFiles/profile-control.dat" / profile file name
"../latflow-files.dat" / lateral inflow bs file name
02-01-2000 / date run begins
00:00:00 / time run begins
01-10-2001 / date run ends
00:00:00 / time run ends
0.5 / delta t in hours (0.5 for flow only; 0.02 for transport)
336 / printout frequency