MASS1 Configuration File

Format

Most lines in the configuration file contain one value. It's best to put a slash (/) after the required data on each line. Comments can appear after the /, as shown in the example below. Those items with their description struck out are not available or ignored, either because they are no longer needed or computed internally. Items

Line Field Type Description
1 1 string Run title -- for user documentation only
2 1 flag Enable hydrodynamics simulation
3 1 flag Enable lateral inflow
4 1 flag Enable TDG simulation
5 1 flag Enable temperature simulation
6 1 flag Enable detailed results print out
7 1 flag Enable gage results output
8 1 flag Enable profile results output
2 flag Average gage and profile output over output time
9 1 flag Enable TDG dispersion
10 1 flag Enable atmospheric TDG exchange (requires met data)
11 1 flag Enable temperature dispersion
12 1 flag Enable atmospheric energy exchange (requires met data)
13 1 flag If true, read initial conditions from a hotstart file
otherwise, read initial conditions file
14 1 flag Write a hotstart file at the end of simulation
15 1 int Units option: 0 = English, 1 = metric1 (only 0 works)
16 1 int Time option: 0 = real2, 1 = date/time
17 1 int Units used for channel length in the point file:
0 = feet, 1 = meters, 2 = miles, 3 = kilometers
18 1 int Boundary condition at outlet:
0 = stage, 1 = discharge
19 1 int Maximum number of links (>= actual number of links)
20 1 int Maximum number of points on a link
21 1 int Maximum number of values in a BC file
22 1 int Number of transport time sub-steps (0 = automatic)
23 1 flag Enable debugging output
24 1 string Link file name
25 1 string Point file name
26 1 string Section file name
27 1 string Link BC file name
28 1 string Initial conditions file name
29 1 string Output file name
30 1 string TDG BC file name
31 1 string Temperature BC file name
32 1 string Meteorologic zone table file name
33 1 string Hydropower BC file name
34 1 string TDG Coefficients file name
35 1 string Restart file from which initial conditions are read
36 1 string Hotstart file to write
37 1 string Gage control file name
38 1 string Profile control file name
39 1 string Lateral inflow BC file name
40 1 string Simulation start date (mm-dd-yyyy)
41 1 string Simulation start time (HH:MM:SS)
42 1 string Simulation end date (mm-dd-yyyy)
43 1 string Simulation end time (HH:MM:SS)
44 1 real Hydrodynamics time step
2 string Optional time step units, one of: hr, min, day, and sec. hr is default.
45 1 int Gage and profile output frequency (time steps)

Example

MASS1 Configuration File - Version 0.83
1	/	Do Flow
0	/	Do lateral inflow
0	/	Do Gas
0	/	Do Temp
0	/	Do Printout
1	/	Do Gage Printout
1	/	Do Profile Printout
0	/	Do Gas Dispersion
0	/	Do Gas Air/Water Exchange
1	/	Do Temp Dispersion
1	/	Do Temp surface exchange
1	/	Do Hotstart read file
0	/	Do Restart write file
0	/	Do Print section geometry
0	/	Do write binary section geom
0	/	Do read binary section geom
0	/	units option
1	/	time option
2	/	time units
2	/	channel length untis
0	/	downstream bc type
5	/	max links
400	/	max points on a link
28	/	max bc table
60000	/	max times in a bc table
1379	/	total number of x-sections
15  /   number of transport sub time steps
0 	/	debug print flag
"../BaseFiles/prd2mcn.link"	/	link file name
"../BaseFiles/prd2mcn.point"	/	point file name nonuniform manning n
"../BaseFiles/CAN2MCN.dat" 	/	section file name
"link-bc-files.dat"	/	linkBC file name
"initial.dat" 	/	initial file name
"output.out" 	/	output file name
"./transbc-files.dat"	/	gas transport file name
"temp-bc-files.dat"	/	temperature input
"weather-files.dat"	/	weather data files for each met_zone input
"./hydrobc-init.dat" /	hydropower file name
"../Common_Files/tdg_coeff.dat" 	/	TDG Coeff file name
"../Rampdown/restart.dat" 	/	hotstart-warmup-unix.dat /	read restart file name
"hotstart.dat" /	Write restart file name
"../BaseFiles/gage-control.dat"			/	gage control file name
"../BaseFiles/profile-control.dat" 	 	/	profile file name
"../latflow-files.dat"     		/	lateral inflow bs file name
02-01-2000	/	date run begins
00:00:00	/	time run begins
01-10-2001	/	date run ends
00:00:00	/	time run ends
0.5	/	delta t in hours (0.5 for flow only; 0.02 for transport)
336	/	printout frequency

Footnotes

  1. The metric units option is untested and probably doesn't work.

  2. Using decimal time in time series input no longer works, so don't try it.