smart micro solar lose conection to openDTU 3 or 4 times a day #2126
Comments
@Tom-Solar I am sorry for my english too :) It is normal for the inverter to be unreachable during night times. As the whole inverter is powered only by the DC / PV panels connected to it. Regarding the smaller outages during daytime this could be connection problems. You are using HM models which can be reached via NRF24L01+ Modules using the so called Enhanced Shockburst protocol by Nordic Semiconductors. This is usually only for short distance communication like Bluetooth mice/keyboards/headphones. Ie the link relies heavily on your hardware setup, antenna direction, a stable power/voltage source and also what you send to the inverter. It has been seen that the inverter may seize responding if you send it repeatedly or too frequently (the same) Active Power Limit commands or query it too frequently. |
@stefan123t Current setup: In mornings and evenings the connection is stable, most outages happen during the afternoon at the hottest parts of the day. |
@taneltumanski can you show a picture or two of your setup. I recall that the BlinkyParts CMT Breakout board has some tiny weeny pins to solder. |
Maybe same issue as here? As I mentioned in the corresponding thread, changing the frequency "solves" the issue. Happens several times a day on my side. |
@lehmartin no as explained elsewhere the HM models NRF communication chip is distinct from CMT communication chip in HMS/HMT models. Frequency hopping is used in CMT and your situation, whereas @Tom-Solar has three HM model inverters and needs to respond to this Issue in order to answer our questions and progress this issue. |
What happened?
smart micro say there is a conection to dtu but the parameter do not arrive in dtu.
To Reproduce Bug
i just start both
Expected Behavior
smart micro send values to dtu but dtu stays at the value to the time the connection get lost.
1 x hoymiles hm 800 and 1 x hoymiles hm1500. sometimes hm1500 is in funktion and hm800 akt with one value the hole time. i have to restart both then it will go on normal til it wil loose conection again. ( i‘m sorry about my english)
Install Method
Pre-Compiled binary from GitHub
What git-hash/version of OpenDTU?
v24.6.10
Relevant log/trace output
No response
Anything else?
No response