Neware Database Documentation

Minimal documentation and list of queries

NB: current version of the Neware Report Exportation Software = V1.0.0.4_20240123_64

Database structure

alt text

Table description and definitions

A test is defined by a protocol, which is a list of steps with their settings.

Example of a protocol:

  1. rest for 10’

  2. charge at constant current (CC phase) of C/5 for 6h

  3. charge at constant voltage (CV phase) of 4.3V, cutoff current C/20 for 1h

  4. rest for 10’

  5. discharge at constant current of C/2 for 3h

  6. rest for 10’

  7. repeat from step 2 for 999 times

The database is composed by the following landing tables:

  • channel_status

  • cycle

  • step

  • record

  • schedule

  • log

Each table resumes the performed test on a different aggregation level:

Channel status table describes the current status of all the available channels, the rows of this table are fixed to the number of channels.

Cycle table is the highest aggregation level, it describes the parameters of the test for each cycle, which is defined by the steps from the first charge step to the last discharge step (from 2 to 6 in the example). Example: the charged capacity will be the sum of the charged capacity of the step 2 and 3, the cycle duration is the sum of the duration of the step from 2 to 6, etc..

Step table describes the parameters of the test for each step (the steps from 1 to 6 in the example). Example: there will be the duration of each step, the charged capacity for the CC and the charged capacity for the CV phase, etc..

Record table is the lowest aggregation level and it can be very big, it contains all the datapoints of the test. Example if the sampling rate is 1Hz (1 point every second) only the step 1 of the Example protocol will produce 36000 rows! The least amount of parameter to measure are voltage, current, capacity, energy and power, so the corresponding table for the step 1 will contain 36000x5=180000 elements!!

Schedule table resumes the protocol executed in each test.

Log table describes the logs of each test.

List of variables and types

Table Select Parameter Unit Decimal point Type of data Length string Field name Default value Primary Key new name
0 channel_status True Computer name nan nan string 20 nan nan nan computer_name
1 channel_status True Device ID nan 0 int nan equiptCode nan nan equipt_code
2 channel_status True Unit ID nan 0 int nan channelNo nan nan channel_no
3 channel_status True CH ID nan 0 int nan channelCode nan nan channel_code
4 channel_status False Local IP nan nan string 20 localIP nan nan nan
5 channel_status True Computer name nan nan string nan pcName nan nan pc_name
6 channel_status True Barcode nan 0 string 60 packBarCode empty string YES barcode
7 channel_status False System state nan nan string nan systemStatus nan nan nan
8 channel_status False Test program name nan nan string nan solutionName nan nan nan
9 channel_status False Test project name nan nan string nan projectName nan nan nan
10 channel_status False Test project number nan nan string nan projectNO nan nan nan
11 channel_status True Step Index nan 0 int nan stepNO nan nan step_id
12 channel_status False Cycle group number nan nan string nan cycleGroupNO nan nan nan
13 channel_status True Cycle count nan 0 int nan cycleCount nan nan cycle_id
14 channel_status True Step Time ms 0 bigint nan stepTime nan nan step_duration
15 channel_status True Total Time ms 0 bigint nan totalTime nan nan total_duration
16 channel_status True Charge and discharge system state nan nan string 20 btsSysState nan nan nan
17 channel_status False Charge and discharge operation mode nan nan string nan btsRunMode nan nan nan
18 channel_status False Charge and discharge control mode nan nan string nan btsControlMode nan nan nan
19 channel_status True Voltage V 3 double nan voltage nan nan nan
20 channel_status True Current A 3 double nan current nan nan nan
21 channel_status True Power W 3 double nan power nan nan nan
22 channel_status True Capacity Ah 3 double nan stepAH nan nan step_capacity
23 channel_status True Total capacity Ah 3 double nan totalAH nan nan total_capacity
24 channel_status True Energy Wh 3 double nan stepKWH nan nan step_energy
25 channel_status True Total energy Wh 3 double nan totalKWH nan nan total_energy
26 channel_status True Total Chg Cap. Ah 3 double nan totalChargeAH nan nan total_charge_capacity
27 channel_status True Total DChg Cap. Ah 3 double nan totalDisChargeAH nan nan total_discharge_capacity
28 channel_status True Total Chg Eng. Wh 3 double nan totalChargeKWH nan nan total_charge_energy
29 channel_status True Total DChg Eng. Wh 3 double nan totalDisChargeKWH nan nan total_discharge_energy
30 channel_status True Voltage setting value V 3 double nan voltageSetting nan nan voltage_setting
31 channel_status True Current setting value A 3 double nan currentSetting nan nan current_setting
32 channel_status True Aux. Vmax V 3 double nan maxSingleVoltage nan nan max_single_voltage
33 channel_status True Aux. Vmin V 3 double nan minSingleVoltage nan nan min_single_voltage
34 channel_status True Aux. Tmax 2 double nan maxSingleTemperature nan nan max_single_temperature
35 channel_status True Aux. Tmin 2 double nan minSingleTemperature nan nan min_single_temperature
36 channel_status True Date unix timestamp nan bigint nan transmitTime nan nan transmit_time
37 channel_status True Aux CH volt. V 3 double nan singleVoltage nan nan single_voltage
38 channel_status True Aux CH temp. 2 double nan singleTemperature nan nan single_temperature
39 channel_status False Laboratory nan nan string nan laboratory nan nan nan
40 channel_status False Area nan nan string nan area nan nan nan
41 channel_status False Supplier nan nan string nan supplier nan nan nan
42 channel_status True ΔTemperature nan double nan delta_temperature nan nan nan
43 channel_status True Step Name nan nan string 20 step_name nan nan nan
44 channel_status True Device IP nan nan string 20 device_IP nan nan nan
45 channel_status True Upload time unix timestamp nan bigint nan upload_time nan nan nan
46 channel_status True End time duration ms nan bigint nan end_time nan nan nan
47 schedule True nan nan nan int nan test_id 0 YES nan
48 schedule True nan nan nan int nan seq_id nan nan nan
49 schedule True nan nan nan string 20 computer_name nan nan nan
50 schedule True CH ID nan nan string 20 chl_id nan nan nan
51 schedule True Cell bar code nan nan string 60 barcode empty string YES nan
52 schedule True Step Index nan 0 int nan step_id nan nan nan
53 schedule True Step Name 工步简称 nan string 15 step_type nan nan nan
54 schedule True Step Time ms nan bigint nan step_time nan nan step_duration
55 schedule True Voltage V 4 double nan setting_voltage nan nan nan
56 schedule True C-rate nan nan string nan setting_rate nan nan nan
57 schedule True Current A 4 double nan setting_current nan nan nan
58 schedule True Cut-off C-rate nan nan string nan cut_of_rate nan nan nan
59 schedule True Cut-off curr. A 4 double nan cut_of_current nan nan nan
60 schedule True Energy Wh 4 double nan energy nan nan nan
61 schedule True -ΔV V 4 double nan DV nan nan nan
62 schedule True Power W 4 double nan power nan nan nan
63 schedule True Resistance 4 double nan IR nan nan nan
64 schedule True Capacity Ah 4 double nan capacity nan nan nan
65 schedule True Record settings s,V,A nan string 100 recording_conditions nan nan nan
66 schedule True Aux.CH recording condition s,V,A nan string 100 aux_record_conditions nan nan nan
67 schedule True Max Vi V nan double nan MaxVi nan nan nan
68 schedule True Min Vi V nan double nan MinVi nan nan nan
69 schedule True Max Ti nan double nan MaxTi nan nan nan
70 schedule True Min Ti nan double nan MinTi nan nan nan
71 schedule True Segment record1 nan nan string 100 record1 nan nan nan
72 schedule True Segment record2 nan nan string 100 record2 nan nan nan
73 schedule True Test start time unix timestamp nan bigint nan StartTime nan nan starting_time
74 schedule True Test end time unix timestamp nan bigint nan EndTime nan nan end_time
75 schedule True Remarks nan nan string 60 Remark nan nan nan
76 schedule True P/N nan nan string 25 P nan nan nan
77 schedule True Builder nan nan string 25 Builder nan nan builder
78 schedule True Active material mg nan double nan Active_material nan nan nan
79 schedule True Cut-off voltage V nan double nan curoff_voltage nan nan nan
80 schedule True Start step ID nan nan int nan start_step_ID nan nan nan
81 schedule True Cycle count nan nan int nan cycle_count nan nan nan
82 schedule True Upload time unix timestamp nan bigint nan upload_time nan nan nan
83 schedule True Customize settings nan nan string 100 customize_setting nan nan nan
84 schedule True Customize settings2 nan nan string 100 customize_setting_2 nan nan nan
85 schedule True Equipment remarks nan nan string 50 DevRemark nan nan equipment_remarks
86 cycle True nan nan nan int nan test_id 0 YES nan
87 cycle True nan nan nan int nan seq_id nan nan nan
88 cycle True nan nan nan string 20 computer_name nan nan nan
89 cycle True CH ID nan nan string 20 chl_id nan nan nan
90 cycle True Cell bar code nan nan string 60 barcode empty string YES nan
91 cycle True Cycle Index nan nan int nan cycle_id nan nan nan
92 cycle True Chg. Cap. Ah 4 double nan charge_capacity nan nan nan
93 cycle True DChg. Cap. Ah 4 double nan discharge_capacity nan nan nan
94 cycle True Chg. Energy Wh 4 double nan charge_energy nan nan nan
95 cycle True DChg. Energy Wh 4 double nan discharge_energy nan nan nan
96 cycle True Net DChg. Cap. Ah 4 double nan Net_cap_dchg nan nan net_discharge_capacity
97 cycle True Net DChg. Energy Wh 4 double nan Net_eng_dchg nan nan net_discharge_energy
98 cycle True Chg. Med. Volt. V 4 double nan chg_mid_voltage nan nan charge_mid_voltage
99 cycle True DChg. Med. Volt. V 4 double nan dc_mid_voltage nan nan discharge_mid_voltage
100 cycle True Process name nan nan string 60 batch_no nan nan nan
101 cycle True Remarks nan nan string 60 Remark nan nan remark
102 cycle True Starting time unix timestamp nan bigint nan staring_time nan nan nan
103 cycle True End time unix timestamp nan bigint nan end_time nan nan nan
104 cycle True Builder nan nan string 25 builder nan nan nan
105 cycle True Active material nan nan double nan active_material nan nan nan
106 cycle False Active materialUnit nan nan string nan active_material_unit nan nan nan
107 cycle True Discharge capacity attenuation rate (%) % 4 string nan dicharge_capacity_attenuation_rate nan nan nan
108 cycle False Aux. Tmax 4 string nan nan nan nan nan
109 cycle False Aux. Tmin 4 string nan nan nan nan nan
110 cycle False Upload time hh:mm:ss 4 string nan nan nan nan nan
111 cycle False Data upload completion identification nan 4 string nan nan nan nan nan
112 cycle False Charge capacity retention rate % 4 string nan nan nan nan nan
113 cycle False Discharge capacity retention rate % 4 double nan nan nan nan nan
114 cycle False Charge energy retention rate % 4 string nan nan nan nan nan
115 cycle True Discharge energy retention rate % 4 double nan discharge_energy_retention_rate nan nan nan
116 cycle False Charge capacity retention rate % 4 string nan nan nan nan nan
117 cycle True Discharge capacity retention rate % 4 double nan soh nan nan nan
118 cycle False Mutation retention rate % 4 string nan nan nan nan nan
119 cycle True Chg.-DChg. Eff % 4 double nan charge_discharge_efficiency nan nan nan
120 cycle False constant volt ratio % 4 string nan nan nan nan nan
121 cycle True Charging capacity mAh/g 4 double nan specific_charge_capacity nan nan nan
122 cycle True Specific discharge capacity mAh/g 4 double nan specific_discharge_capacity nan nan nan
123 cycle True Charge specific energy mWh/g 4 double nan specific_charge_energy nan nan nan
124 cycle True Discharge specific energy mWh/g 4 double nan specific_discharge_energy nan nan nan
125 step True nan nan nan int nan test_id 0 YES nan
126 step True nan nan nan int nan seq_id nan nan nan
127 step True nan nan nan string 20 computer_name nan nan nan
128 step True CH ID nan nan string 20 chl_id nan nan nan
129 step True Cell bar code nan nan string 60 barcode empty string YES nan
130 step True Cycle Index nan nan int nan cycle_id nan nan nan
131 step True Step Number nan nan int nan step_num nan nan nan
132 step True Original step nan nan int nan step_id nan nan nan
133 step True Step Name 工步简称 nan string 15 step_type nan nan nan
134 step True Step Time ms 0 bigint nan step_time nan nan step_duration
135 step True Step file name nan nan string `150 step_file_name nan nan nan
136 step True Chg. Energy Wh 4 double nan chg_energy nan nan charge_energy
137 step True DChg. Energy Wh 4 double nan dc_energy nan nan discharge_energy
138 step False Chg. Med. Volt. V 4 string nan chg_mid_voltage nan nan nan
139 step True Chg. Cap. Ah 4 double nan chg_capacity nan nan charge_capacity
140 step True DChg. Cap. Ah 4 double nan dchag_capacity nan nan discharge_capacity
141 step False DChg. Med. Volt. V 4 string nan dc_mid_voltage nan nan nan
142 step True Net DChg. Cap. Ah 4 double nan Net_cap_dchg nan nan net_discharge_capacity
143 step True Net DChg. Energy Wh 4 double nan Net_eng_dchg nan nan net_discharge_energy
144 step True Chg. Time ms 0 bigint nan chg_time nan nan charge_time
145 step True DChg. Time ms 0 bigint nan dchg_time nan nan discharge_time
146 step True Oneset Volt. V 4 double nan start_voltage nan nan nan
147 step True End Voltage V 4 double nan end_voltage nan nan nan
148 step True End T 4 double nan end_temp nan nan nan
149 step True Process name nan nan string 25 batch_no nan nan nan
150 step True Starting time unix timestamp nan bigint nan starting_time nan nan nan
151 step True End time unix timestamp nan bigint nan end_time nan nan nan
152 step True Remarks nan nan string 60 Remark nan nan nan
153 step True Builder nan nan string 25 builder nan nan nan
154 step True Active material mg nan double nan active_material nan nan nan
155 step False Active materialUnit nan nan string nan nan nan nan nan
156 step True Starting current A nan double nan start_current nan nan nan
157 step True End Current A nan double nan end_current nan nan nan
158 step True Capacity Ah nan double nan capacity nan nan nan
159 step True Energy Wh nan double nan energy nan nan nan
160 step False Constant current ratio % nan string nan nan nan nan nan
161 step False Upload time hh:mm:ss nan string nan nan nan nan nan
162 step False Data upload completion identification nan nan string nan nan nan nan nan
163 step True First current at non-zero time A 4 double nan first_current nan nan nan
164 step True First voltage at non-zero time V 4 double nan first_voltage nan nan nan
165 step True Nominal capacity mAh nan double nan nominal_capacity nan nan nan
166 record True nan nan nan int nan test_id 0 YES nan
167 record True nan nan nan int nan seq_id nan nan nan
168 record True nan nan nan string 20 computer_name nan nan nan
169 record True CH ID nan nan string 20 chl_id nan nan nan
170 record True Cell bar code nan nan string 60 barcode empty string YES nan
171 record True Cycle Index nan nan int nan cycle_id nan nan nan
172 record True Step Number nan nan int nan step_num nan nan nan
173 record True Original step nan nan int nan step_id nan nan nan
174 record True DataPoint nan nan int nan record_id nan nan nan
175 record True Step Name 工步简称 nan string 20 step_type nan nan nan
176 record True Record time ms 0 bigint nan record_time nan nan nan
177 record True Voltage V 4 double nan voltage nan nan nan
178 record True Current A 4 double nan current nan nan nan
179 record True Capacity Ah 4 double nan capacity nan nan nan
180 record True Energy Wh 4 double nan energy nan nan nan
181 record True Power W 4 double nan power nan nan nan
182 record True Date unix timestamp nan bigint nan abs_time nan nan absolute_time
183 record True Aux CH temp. 4 string 255 temperature nan nan nan
184 record True Process name nan nan string 25 batch_no nan nan nan
185 record True Remarks nan nan string 60 Remark nan nan nan
186 record True Builder nan nan string 25 builder nan nan nan
187 record True Active material nan nan double nan active_material nan nan nan
188 record False Active materialUnit nan nan string nan active_material_unit nan nan nan
189 record False Aux. Vmax V nan string nan nan nan nan nan
190 record False Aux. Vmin V nan string nan nan nan nan nan
191 record False Aux. Tmax nan string nan nan nan nan nan
192 record False Aux. Tmin nan string nan nan nan nan nan
193 record False Upload time hh:mm:ss nan string nan nan nan nan nan
194 record False Data upload completion identification nan nan string nan nan nan nan nan
195 record True Customize settings nan nan string 255 customize_settings nan nan nan
196 record True Customize settings2 nan nan string 255 customize_settings_2 nan nan nan
197 record True Equipment remarks nan nan string 100 equipment_remarks nan nan nan
198 record True Total Time ms 0 bigint nan TotalTime nan nan total_time
199 log True nan nan nan int nan test_id 0 YES nan
200 log True nan nan nan int nan seq_id nan nan nan
201 log True nan nan nan string 20 computer_name nan nan nan
202 log True CH ID nan nan string 20 chl_id nan nan nan
203 log True Time unix timestamp nan bigint nan log_time nan nan nan
204 log True Cell bar code nan nan string 60 barcode empty string YES nan
205 log True Log code nan nan string 25 log_code nan nan nan
206 log True Class nan nan string 5 log_level nan nan nan
207 log True Event nan nan string 200 log_event nan nan nan
208 log True Upload time unix timestamp nan bigint nan upload_time nan nan nan

Folder testlab-db

MySQL scripts to define the casted tables and the triggers

Folder vmp

Python script to open a measurement file and create a pandas dataframe with the structure of a database table It includes some exception handling for ill formatted filenames

Folder qualification

MySQL queries to fetch the result of the qualification protocols

Folder calculation_neware_db

MySQL queries to create views with calculation of quantities like DCIR, dQ/dV, step durations, step capacities and step end voltages