Notifications
You must be signed in to change notification settings - Fork 2.1k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Cura 12069 move machine nozzle head distance #19483
Cura 12069 move machine nozzle head distance #19483
Conversation
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Clang-Tidy
found issue(s) with the introduced code (1/1)
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I don't even think we're using this right now? (Maybe we'd have found it earlier if we did already...) In any case, the switch to extruder doesn't seem to give a problem right now.
machine_nozzle_head_distance original definition is in fdmPrinter and not in fdmExtruder. So on the Cura side it's not overriding the setting with the values defined in left extruder of ultimaker s5 (value 2.7 for left extruder) for example but instead takes the default value of 3 in fdmPrinter. So initial impression would be that the Cura results are invalid