This repository has been archived by the owner on Apr 14, 2021. It is now read-only.
fritzctl 1.4.20
- Command
temperature
supports reset to "comfort" and "saving" viarespectively.fritzctl temperature comf <devices> fritzctl temperature sav <devices>
- Experimental:
list thermostats
as well aslist switches
now have an option--output=json
, which serializes the data into json format and prints it to stdout. An example is:{ "numberOfItems": 1, "devices": [ { "id": "44363 2777777", "internalId": "12", "name": "HKR_1", "properties": { "vendor": { "manufacturer": "AVM", "productName": "Comet DECT", "firmwareVersion": "03.54" }, "lock": { "hwLock": "LOCKED", "swLock": "UNLOCKED" }, "warnings": [ "Battery is running on low capacity" ] }, "measurements": { "temperature": "20.5" }, "state": { "connected": true, "temperatureControl": { "goal": "OFF", "saving": "18", "comfort": "20", "nextChange": { "at": "2017-09-30T23:00:00+02:00", "goal": "20" } } } } ] }
- Improve error message when no configuration file is found.
- NOTICE file and debian copyright file
- Upgrade of 3rd party dependencies.