Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

fix bug when traversing ems devices when using cmd allvalues #1426

Merged
merged 2 commits into from
Nov 15, 2023
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
6 changes: 3 additions & 3 deletions src/emsdevice.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -817,7 +817,7 @@ std::string EMSdevice::get_value_uom(const std::string & shortname) const {
return std::string{}; // not found
}

bool EMSdevice::export_values(uint8_t device_type, JsonObject & output, const int8_t id, const uint8_t output_target) {
bool EMSdevice::export_values(uint8_t unique_id, JsonObject & output, const int8_t id, const uint8_t output_target) {
bool has_value = false;
uint8_t tag;
if (id >= 1 && id <= (1 + DeviceValueTAG::TAG_HS16 - DeviceValueTAG::TAG_HC1)) {
Expand All @@ -830,7 +830,7 @@ bool EMSdevice::export_values(uint8_t device_type, JsonObject & output, const in

if (id > 0 || output_target == EMSdevice::OUTPUT_TARGET::API_VERBOSE) {
for (const auto & emsdevice : EMSESP::emsdevices) {
if (emsdevice && (emsdevice->device_type() == device_type)) {
if (emsdevice->unique_id() == unique_id) {
has_value |= emsdevice->generate_values(output, tag, (id < 1), output_target); // use nested for id -1 and 0
}
}
Expand All @@ -842,7 +842,7 @@ bool EMSdevice::export_values(uint8_t device_type, JsonObject & output, const in
JsonObject output_hc = output;
bool nest_created = false;
for (const auto & emsdevice : EMSESP::emsdevices) {
if (emsdevice && (emsdevice->device_type() == device_type)) {
if (emsdevice->unique_id() == unique_id) {
if (!nest_created && emsdevice->has_tags(tag)) {
output_hc = output.createNestedObject(EMSdevice::tag_to_mqtt(tag));
nest_created = true;
Expand Down
12 changes: 4 additions & 8 deletions src/system.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -112,14 +112,10 @@ bool System::command_allvalues(const char * value, const int8_t id, JsonObject &
DynamicJsonDocument doc(EMSESP_JSON_SIZE_XXXLARGE);
JsonObject device_output;

for (const auto & device_class : EMSFactory::device_handlers()) {
for (const auto & emsdevice : EMSESP::emsdevices) {
if (emsdevice->device_type() == device_class.first) {
std::string title = emsdevice->device_type_2_device_name_translated() + std::string(" ") + emsdevice->to_string();
device_output = output.createNestedObject(title);
emsesp::EMSdevice::export_values(emsdevice->device_type(), device_output, id, EMSdevice::OUTPUT_TARGET::API_VERBOSE);
}
}
for (const auto & emsdevice : EMSESP::emsdevices) {
std::string title = emsdevice->device_type_2_device_name_translated() + std::string(" ") + emsdevice->to_string();
device_output = output.createNestedObject(title);
emsesp::EMSdevice::export_values(emsdevice->unique_id(), device_output, id, EMSdevice::OUTPUT_TARGET::API_VERBOSE);
}

// Custom entities
Expand Down
9 changes: 6 additions & 3 deletions src/test/test.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -37,19 +37,22 @@ bool Test::run_test(const char * command, int8_t id) {

// simulate HansRemmerswaal's setup - see https://github.com/emsesp/EMS-ESP32/issues/859
add_device(0x08, 172); // 176 entities - boiler: Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i

// add_device(0x10, 158); // 62 entities - thermostat: RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410
// add_device(0x38, 200); // 4 entities - thermostat: RC100H
add_device(0x10, 158); // 62 entities - thermostat: RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410
add_device(0x38, 200); // 4 entities - thermostat: RC100H

return true;
}

if (strcmp(command, "general") == 0) {
EMSESP::logger().info("Testing general. Adding a Boiler and Thermostat");

// System::test_set_all_active(true); // uncomment if we want to show all entities and give them fake values

add_device(0x08, 123); // Nefit Trendline
add_device(0x18, 157); // Bosch CR100

// add_device(0x10, 158); // RC300 - there's no data here

// add some data
// Boiler -> Me, UBAMonitorFast(0x18), telegram: 08 00 18 00 00 02 5A 73 3D 0A 10 65 40 02 1A 80 00 01 E1 01 76 0E 3D 48 00 C9 44 02 00 (#data=25)
uart_telegram({0x08, 0x00, 0x18, 0x00, 0x00, 0x02, 0x5A, 0x73, 0x3D, 0x0A, 0x10, 0x65, 0x40, 0x02, 0x1A,
Expand Down