90 changes: 40 additions & 50 deletions docs/docs/about/modelling/examples/drogon.md
Original file line number Diff line number Diff line change
Expand Up @@ -30,7 +30,7 @@ The results of a performed characterization of the equipment are listed below:
| Consumer |Type | Description |
|----------------------------------|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------|
| Generator set A |Generator set | Variable fuel consumer with electricity to fuel function |
| Base production load |Power consumer | Constant load - 10 MW |
| Base production load |Power consumer | Constant load - 9 MW |
| Gas compression train |Power consumer | Variable consumption depending on produced gas rate |
| Gas re-compressors |Power consumer | Constant load - 2 MW |
| Sea water injection pump |Power consumer | Variable consumption depending on water injection rate |
Expand Down Expand Up @@ -76,16 +76,16 @@ TIME_SERIES:

In this case, the compressors are not specified in this section as [GENERIC COMPRESSOR CHARTS](/about/modelling/setup/models/compressor_modelling/compressor_charts/index.md). Thus, the pump chart and generator set will be the only facility components specified within this section.

The pump will be variable speed, meaning that the pump type will be `PUMP_CHART_VARIABLE_SPEED`. The generator set will be a tabulated, where power consumption will be linked to fuel gas utilised.
The pump will be single speed, meaning that the pump type will be `PUMP_CHART_SINGLE_SPEED`. The generator set will be a tabulated, where power consumption will be linked to fuel gas utilised.

~~~~~~~~yaml
FACILITY_INPUTS:
- NAME: genset_a_power_fuel
TYPE: ELECTRICITY2FUEL
FILE: genset.csv
- NAME: wi_200
FILE: wi_200bar_vsp.csv
TYPE: PUMP_CHART_VARIABLE_SPEED
FILE: wi_200bar_ssp.csv
TYPE: PUMP_CHART_SINGLE_SPEED
UNITS:
HEAD: M
RATE: AM3_PER_HOUR
Expand Down Expand Up @@ -155,7 +155,7 @@ In the `INSTALLATIONS` section, the previously defined models and facility input

~~~~~~~~yaml
INSTALLATIONS:
- NAME: drogon
- NAME: drogon_installation
CATEGORY: FIXED
HCEXPORT: SIM1;OIL_PROD {+} SIM1;GAS_PROD {/} 1000
FUEL: fuel_gas
Expand Down Expand Up @@ -184,7 +184,7 @@ As only one pump has been defined, the same pump model will be used for each tra
A fluid density of 1025 kg/m<sup>3</sup> is used, with a suction and discharge pressure of 12 and 200 bar respectively.

~~~~~~~~yaml
- NAME: wi_lp
- NAME: water injection
CATEGORY: PUMP
ENERGY_USAGE_MODEL:
TYPE: PUMP_SYSTEM
Expand Down Expand Up @@ -212,17 +212,22 @@ A fluid density of 1025 kg/m<sup>3</sup> is used, with a suction and discharge p

For the compression model, a compressor system is not used. This is due to the use of generic compressor charts. As the generic charts are shifted from input data there is no need for an additional compression train. No matter what rate/head values are inputted here, the generic chart is shifted so that all operational points will be within the operational envelope of the compressor.

Here, 13 bar and 431 bar is specified for the suction and discharge pressure respectively.
Here, 13 bar and 421 bar is specified for the suction and discharge pressure respectively.

~~~~~~~~yaml
- NAME: compressor_train
- NAME: gas export compressor train
CATEGORY: COMPRESSOR
ENERGY_USAGE_MODEL:
TYPE: COMPRESSOR
ENERGYFUNCTION: simplified_compressor_train_model
RATE: SIM1;GAS_PROD
SUCTION_PRESSURE: 13
DISCHARGE_PRESSURE: 421
TYPE: COMPRESSOR_SYSTEM
COMPRESSORS:
- NAME: train1_2
COMPRESSOR_MODEL: simplified_compressor_train_model
TOTAL_SYSTEM_RATE: SIM1;GAS_PROD
OPERATIONAL_SETTINGS:
- RATE_FRACTIONS:
- 1
SUCTION_PRESSURE: 13
DISCHARGE_PRESSURE: 421
~~~~~~~~

#### BASE-LOAD
Expand All @@ -239,7 +244,7 @@ Three different constant-loads are specified in this section. These being the bo
CATEGORY: BASE-LOAD
ENERGY_USAGE_MODEL:
TYPE: DIRECT
LOAD: 10
LOAD: 9
- NAME: re-compressors
CATEGORY: BASE-LOAD
ENERGY_USAGE_MODEL:
Expand All @@ -260,8 +265,8 @@ FACILITY_INPUTS:
FILE: genset.csv
TYPE: ELECTRICITY2FUEL
- NAME: wi_200
FILE: wi_200bar_vsp.csv
TYPE: PUMP_CHART_VARIABLE_SPEED
FILE: wi_200bar_ssp.csv
TYPE: PUMP_CHART_SINGLE_SPEED
UNITS:
HEAD: M
RATE: AM3_PER_HOUR
Expand Down Expand Up @@ -303,7 +308,7 @@ FUEL_TYPES:
- NAME: co2_fuel_gas
FACTOR: 2.416
INSTALLATIONS:
- NAME: drogon
- NAME: drogon_installation
CATEGORY: FIXED
HCEXPORT: SIM1;OIL_PROD {+} SIM1;GAS_PROD {/} 1000
FUEL: fuel_gas
Expand Down Expand Up @@ -335,14 +340,19 @@ INSTALLATIONS:
SUCTION_PRESSURE: 12
DISCHARGE_PRESSURE: 200

- NAME: compressor_train
- NAME: gas export compressor train
CATEGORY: COMPRESSOR
ENERGY_USAGE_MODEL:
TYPE: COMPRESSOR
ENERGYFUNCTION: simplified_compressor_train_model
RATE: SIM1;GAS_PROD
SUCTION_PRESSURE: 13
DISCHARGE_PRESSURE: 421
TYPE: COMPRESSOR_SYSTEM
COMPRESSORS:
- NAME: train1_2
COMPRESSOR_MODEL: simplified_compressor_train_model
TOTAL_SYSTEM_RATE: SIM1;GAS_PROD
OPERATIONAL_SETTINGS:
- RATE_FRACTIONS:
- 1
SUCTION_PRESSURE: 13
DISCHARGE_PRESSURE: 421

- NAME: boosterpump
CATEGORY: BASE-LOAD
Expand All @@ -353,7 +363,7 @@ INSTALLATIONS:
CATEGORY: BASE-LOAD
ENERGY_USAGE_MODEL:
TYPE: DIRECT
LOAD: 10
LOAD: 9
- NAME: re-compressors
CATEGORY: BASE-LOAD
ENERGY_USAGE_MODEL:
Expand Down Expand Up @@ -388,33 +398,13 @@ POWER, FUEL
42.84,283582.3
~~~~~~~~

~~~~~~~~text title="wi_200bar_vsp.csv"
~~~~~~~~text title="wi_200bar_ssp.csv"
RATE,HEAD,EFFICIENCY,SPEED
967,1810,78,4365
900,1900,80.4,4365
700,2280,81,4365
600,2385,78,4365
500,2450,72.5,4365
480,2475,71.5,4365
900,1700,80.4,4157
700,2000,81,4157
600,2130,78,4157
500,2200,72.5,4157
460,2210,69,4157
830,1340,81,3741
800,1400,81.7,3741
600,1675,78,3741
500,1765,72.5,3741
415,1805,66,3741
740,1075,81.5,3326
700,1120,81,3326
500,1350,72.5,3326
400,1405,64.5,3326
365,1425,62,3326
640,800,79.5,2885
600,840,78,2885
400,1050,64.5,2885
320,1075,57,2885
830,1490,81,3741
800,1550,81.7,3741
600,1825,78,3741
500,1915,72.5,3741
415,1955,66,3741
~~~~~~~~

### Timeseries resources
Expand Down
8 changes: 4 additions & 4 deletions docs/docs/about/modelling/examples/simple.md
Original file line number Diff line number Diff line change
Expand Up @@ -131,7 +131,7 @@ For our model, we specify the following variables:
VARIABLES:
hydrocarbon_export_sm3_per_day:
VALUE: SIM;OIL_PROD {+} SIM;GAS_PROD {/} 1000 # divide the gas rate by 1000 to get oil equivalent
salt_water_injection_rate_m3_per_day:
sea_water_injection_rate_m3_per_day:
VALUE: SIM;WATER_INJ {-} SIM;WATER_PROD {+} SIM;WATER_PROD {*} (SIM;WATER_PROD < 1500) {+} (SIM;WATER_PROD {-} 17000) {*} (SIM;WATER_PROD > 17000) {*} (SIM;WATER_PROD < 18500)
gas_export_rate_sm3_per_day:
VALUE: SIM;GAS_PROD
Expand Down Expand Up @@ -315,7 +315,7 @@ The model is specified:
- NAME: Gas export compressor
CATEGORY: COMPRESSOR
ENERGY_USAGE_MODEL:
TYPE: COMPRESSOR
TYPE: GAS-DRIVEN-COMPRESSOR
ENERGYFUNCTION: compressor_with_turbine_sampled
RATE: $var.gas_export_rate_sm3_per_day
SUCTION_PRESSURE: 50 #not used but a number is needed for eCalc
Expand Down Expand Up @@ -358,7 +358,7 @@ FUEL_TYPES:
VARIABLES:
hydrocarbon_export_sm3_per_day:
VALUE: SIM;OIL_PROD {+} SIM;GAS_PROD {/} 1000 # divide the gas rate by 1000 to get oil equivalent
salt_water_injection_rate_m3_per_day:
sea_water_injection_rate_m3_per_day:
VALUE: SIM;WATER_INJ {-} SIM;WATER_PROD {+} SIM;WATER_PROD {*} (SIM;WATER_PROD < 1500) {+} (SIM;WATER_PROD {-} 17000) {*} (SIM;WATER_PROD > 17000) {*} (SIM;WATER_PROD < 18500)
gas_export_rate_sm3_per_day:
VALUE: SIM;GAS_PROD
Expand Down Expand Up @@ -423,7 +423,7 @@ INSTALLATIONS:
- NAME: Gas export compressor
CATEGORY: COMPRESSOR
ENERGY_USAGE_MODEL:
TYPE: COMPRESSOR
TYPE: GAS-DRIVEN-COMPRESSOR
ENERGYFUNCTION: compressor_with_turbine_sampled
RATE: $var.gas_export_rate_sm3_per_day
SUCTION_PRESSURE: 50 #not used but a number is needed for eCalc