modbus: improved config format #7941

Closed
Closed
Show file tree
Hide file tree
Changes from 5 commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
104 changes: 58 additions & 46 deletions plugins/inputs/modbus/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -12,8 +12,9 @@ Registers via Modbus TCP or Modbus RTU/ASCII.
## The plugin supports connections to PLCs via MODBUS/TCP or
## via serial line communication in binary (RTU) or readable (ASCII) encoding
##
## Device name
name = "Device"

## Name of the MODBUS device to read from
device_name = "Device"

## Slave ID - addresses a MODBUS device on the bus
## Range: 0 - 255 [0 = broadcast; 248 - 255 = reserved]
Expand All @@ -22,6 +23,12 @@ Registers via Modbus TCP or Modbus RTU/ASCII.
## Timeout for each request
timeout = "1s"

## Do not add Device Name as Tag
omit_device_name = false

## Do not add Register Type as Tag
omit_register_type = false

## Maximum number of retries and the time to wait between retries
## when a slave-device is busy.
# busy_retries = 0
Expand All @@ -42,49 +49,54 @@ Registers via Modbus TCP or Modbus RTU/ASCII.
## Measurements
##

## Digital Variables, Discrete Inputs and Coils
## measurement - the (optional) measurement name, defaults to "modbus"
## name - the variable name
## address - variable address

discrete_inputs = [
{ name = "start", address = [0]},
{ name = "stop", address = [1]},
{ name = "reset", address = [2]},
{ name = "emergency_stop", address = [3]},
]
coils = [
{ name = "motor1_run", address = [0]},
{ name = "motor1_jog", address = [1]},
{ name = "motor1_stop", address = [2]},
]

## Analog Variables, Input Registers and Holding Registers
## measurement - the (optional) measurement name, defaults to "modbus"
## name - the variable name
## byte_order - the ordering of bytes
## |---AB, ABCD - Big Endian
## |---BA, DCBA - Little Endian
## |---BADC - Mid-Big Endian
## |---CDAB - Mid-Little Endian
## data_type - INT16, UINT16, INT32, UINT32, INT64, UINT64, FLOAT32-IEEE (the IEEE 754 binary representation)
## FLOAT32 (deprecated), FIXED, UFIXED (fixed-point representation on input)
## scale - the final numeric variable representation
## address - variable address

holding_registers = [
{ name = "power_factor", byte_order = "AB", data_type = "FIXED", scale=0.01, address = [8]},
{ name = "voltage", byte_order = "AB", data_type = "FIXED", scale=0.1, address = [0]},
{ name = "energy", byte_order = "ABCD", data_type = "FIXED", scale=0.001, address = [5,6]},
{ name = "current", byte_order = "ABCD", data_type = "FIXED", scale=0.001, address = [1,2]},
{ name = "frequency", byte_order = "AB", data_type = "UFIXED", scale=0.1, address = [7]},
{ name = "power", byte_order = "ABCD", data_type = "UFIXED", scale=0.1, address = [3,4]},
]
input_registers = [
{ name = "tank_level", byte_order = "AB", data_type = "INT16", scale=1.0, address = [0]},
{ name = "tank_ph", byte_order = "AB", data_type = "INT16", scale=1.0, address = [1]},
{ name = "pump1_speed", byte_order = "ABCD", data_type = "INT32", scale=1.0, address = [3,4]},
]
[[inputs.modbus.measurement]]
name = "power"
tags = [
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Hi Henry, I like being able to specify tags here, but saying key = foo, value = bar feels wrong. The existing way to add tags to a plugin lets you say foo = bar. see https://github.com/influxdata/telegraf/blob/master/docs/CONFIGURATION.md#input-plugins I don't think we should add a second tag settings format.

There's not currently a way to have a plugin get arbitrary settings from toml, like we would need in order to get tags in the foo = bar format. The existing plugin level tags table is handled as a special case that accesses the toml ast.

cp.Tags = make(map[string]string)

I'm working on a PR on the OPC UA input (#8389) that groups variables in a similar way to this PR. I'd like to add tags to a group just like you're doing here. I suspect other similar inputs will need this in the future too. I think the tag config syntax should be the same across plugins and I'd like it to be in foo = bar format.

Lets work together to add a way to get tags in foo = bar format for both PRs.

{key = "system", value = "solar"},
{key = "location", value = "roof"},
]

## Digital Variables, Discrete Inputs and Coils
## name - the variable name
## address - variable address

discrete_inputs = [
{ name = "start", address = [0]},
{ name = "stop", address = [1]},
{ name = "reset", address = [2]},
{ name = "emergency_stop", address = [3]},
]
coils = [
{ name = "motor1_run", address = [0]},
{ name = "motor1_jog", address = [1]},
{ name = "motor1_stop", address = [2]},
]

## Analog Variables, Input Registers and Holding Registers
## name - the variable name
## byte_order - the ordering of bytes
## |---AB, ABCD - Big Endian
## |---BA, DCBA - Little Endian
## |---BADC - Mid-Big Endian
## |---CDAB - Mid-Little Endian
## data_type - INT16, UINT16, INT32, UINT32, INT64, UINT64, FLOAT32-IEEE (the IEEE 754 binary representation)
## FLOAT32, FIXED, UFIXED (fixed-point representation on input)
## scale - the final numeric variable representation
## address - variable address

holding_registers = [
{ name = "power_factor", byte_order = "AB", data_type = "FIXED", scale=0.01, address = [8]},
{ name = "voltage", byte_order = "AB", data_type = "FIXED", scale=0.1, address = [0]},
{ name = "energy", byte_order = "ABCD", data_type = "FIXED", scale=0.001, address = [5,6]},
{ name = "current", byte_order = "ABCD", data_type = "FIXED", scale=0.001, address = [1,2]},
{ name = "frequency", byte_order = "AB", data_type = "UFIXED", scale=0.1, address = [7]},
{ name = "power", byte_order = "ABCD", data_type = "UFIXED", scale=0.1, address = [3,4]},
]
input_registers = [
{ name = "tank_level", byte_order = "AB", data_type = "INT16", scale=1.0, address = [0]},
{ name = "tank_ph", byte_order = "AB", data_type = "INT16", scale=1.0, address = [1]},
{ name = "pump1_speed", byte_order = "ABCD", data_type = "INT32", scale=1.0, address = [3,4]},
]
```

### Metrics
Expand Down Expand Up @@ -131,5 +143,5 @@ from unsigned values).

```
$ ./telegraf -config telegraf.conf -input-filter modbus -test
modbus.InputRegisters,host=orangepizero Current=0,Energy=0,Frecuency=60,Power=0,PowerFactor=0,Voltage=123.9000015258789 1554079521000000000
power,device_name=Device,host=orangepizero,type=holding_register,system=solar,location=roof current=0,energy=0,frecuency=60,power=0,power_factor=0,voltage=123.9000015258789 1554079521000000000
```