This project aims to translate the Nissan Consult protocol to CAN bus. It is based on the STM32F103 microcontroller and custom-made board. The adapter is both powered and communicates with the ECU through the 14-pin Consult connector.
500 Kbit/s
ID | DLC | Byte 0 | Byte 1 | Byte 2 | Byte 3 | Byte 4 | Byte 5 | Byte 6 | Byte 7 |
---|---|---|---|---|---|---|---|---|---|
0x666 | 8 | BATTERY_VOLTAGE | COOLANT_TEMP | IGNITION_TIMING | LEFT_O2 | TPS | AAC_VALVE | LEFT_AF_ALPHA | LEFT_AF_ALPHA_SELFLEARN |
0x667 | 8 | VEHICLE_SPEED | TACH_MSB | TACH_LSB | INJ_TIME_MSB | INJ_TIME_LSB | LEFT_MAF_MSB | LEFT_MAF_LSB | |
0x668 | 8 | BIT_1 | BIT_2 | DEVICE_VOLTAGE | First DTC Code | Heartbeat |
- STM32F103TBU6
- MCP2562
- MC74HC4060