Node.js P1-Reader

Node.js package for reading and parsing data from the P1 port of a Dutch Smart Meter. Data is parsed according to the official DSMR4.0 specification by Netbeheer Nederland, which is currently used by most popular Kaifa and Landis+Gyr Smart Meters.

How to use

The serial connection is automatically opened on initiating the P1-Reader. Use the reading event to start receiving data, which should come in every 10 seconds.

var P1Reader = require('p1-reader');
var p1Reader = new P1Reader();

p1Reader.on('reading', function(data) {
    console.log('Currently consuming: ' + data.electricity.received.actual.reading + data.electricity.received.actual.unit);
});

p1Reader.on('error', function(err) {
    console.log('Error while reading: ' + err);
});

Events

The module emits the following events:

  • connected : When a connection with the Smart Meter was successfully setup
  • reading : When a reading is received via the serial connection (should be on a 10 second interval)
  • reading-raw : Same as the reading event but instead returning the raw data as a string
  • error : When the serial connection emits an error
  • close : When the serial connection closes for some reason

Reading structure

The reading event returns the following data structure:

{
    "meterType": "ISk5\2MT382-1000",
    "version": "42",
    "timestamp": "2010-12-09T10:30:20.000Z",
    "equipmentId": "4B384547303034303436333935353037",
    "textMessage": {
        "codes": "3031203631203831",
        "message": "0123456789:;<=>?0123456789:;<=>?0123456789:;<=>?0123456789:;<=>?0123456789:;<=>?"
    },
    "electricity": {
        "received": {
            "tariff1": {
                "reading": 123456.789,
                "unit": "kWh"
            },
            "tariff2": {
                "reading": 123456.789,
                "unit": "kWh"
            },
            "actual": {
                "reading": 1.193,
                "unit": "kW"
            }
        },
        "delivered": {
            "tariff1": {
                "reading": 123456.789,
                "unit": "kWh"
            },
            "tariff2": {
                "reading": 123456.789,
                "unit": "kWh"
            },
            "actual": {
                "reading": 0,
                "unit": "kW"
            }
        },
        "tariffIndicator": 2,
        "threshold": {
            "value": 16.1,
            "unit": "kW"
        },
        "switchPosition": "1",
        "numberOfPowerFailures": 4,
        "numberOfLongPowerFailures": 2,
        "longPowerFailureLog": {
            "count": 2,
            "log": [
                {
                    "startOfFailure": "2010-12-08T14:20:15.000Z",
                    "endOfFailure": "2010-12-08T14:24:15.000Z",
                    "duration": 240,
                    "unit": "s"
                },
                {
                    "startOfFailure": "2010-12-08T14:05:03.000Z",
                    "endOfFailure": "2010-12-08T14:10:04.000Z",
                    "duration": 301,
                    "unit": "s"
                }
            ]
        },
        "voltageSags": {
            "L1": 2,
            "L2": 1,
            "L3": 0
        },
        "voltageSwell": {
            "L1": 0,
            "L2": 3,
            "L3": 0
        },
        "instantaneous": {
            "current": {
                "L1": {
                    "reading": 1,
                    "unit": "A"
                },
                "L2": {
                    "reading": 2,
                    "unit": "A"
                },
                "L3": {
                    "reading": 3,
                    "unit": "A"
                }
            },
            "power": {
                "positive": {
                    "L1": {
                        "reading": 1.111,
                        "unit": "kW"
                    },
                    "L2": {
                        "reading": 2.222,
                        "unit": "kW"
                    },
                    "L3": {
                        "reading": 3.333,
                        "unit": "kW"
                    }
                },
                "negative": {
                    "L1": {
                        "reading": 4.444,
                        "unit": "kW"
                    },
                    "L2": {
                        "reading": 5.555,
                        "unit": "kW"
                    },
                    "L3": {
                        "reading": 6.666,
                        "unit": "kW"
                    }
                }
            }
        }
    },
    "gas": {
        "deviceType": "003",
        "equipmentId": "3232323241424344313233343536373839",
        "timestamp": "2010-12-09T10:00:00.000Z",
        "reading": 12785.123,
        "unit": "m3",
        "valvePosition": "1"
    }
}

Emulator mode

Since your development machine is usually not connected to the serial port directly the emulator mode can be enabled. When enabled the module will not connect to a serial port but instead will use a mocked version that will emit messages according to the DSMR 4.0 specification.

The emulator will emit a reading event every 10 seconds just like an actual Smart Meter would do with the most important variables (timestamp, electricity.received.tariff1, electricity.received.actual, gas.timestamp and gas.reading) being incremented.

Provide the emulator option parameter to run the module in emulator mode:

var p1Reader = new P1Reader({emulator: true});

The emulator defaults can be overriden by passing an emulatorOverrides object, which can contain the following parameters:

  • electricityOffset : Starting value of electricity on tariff 1 in kWh (default: 0)
  • electricityIncrement : Incremental value (every 10 seconds) of electricity on tariff 1 in kW (default: 0.1)
  • gasOffset : Starting value of gas in m3 (default: 0)
  • gasIncrement : Incremental value (every hour) of gas in m3 (default: 0.1)
  • interval : Interval (in seconds) in which readings are emitted (default: 10)
  • intervalGas Interval (in seconds) in which the gas reading is incremented (default: 3600)

Debug mode

In debug mode all raw and parsed packages are written to 2 separate log files (debug-data-raw.log and debug-data-parsed.log) and stored in the directory from which the module was triggered.

Provide the debug option parameter to run the module in debug mode:

var p1Reader = new P1Reader({debug: true});

Force specific serial port

If for some reason the automatic serial port discovery does not work it is possible to force a certain port.

Provide the serialPort option parameter to use a specific serial port:

var p1Reader = new P1Reader({serialPort: '/dev/tty-usbserial1'});

Official DSMR documentation

The official DSMR Smart Meter P1 interface documentation from Netbeheer Nederland can be found here: http://www.netbeheernederland.nl/publicaties/publicatie/?documentregistrationid=1745033 This documentation was used as a reference to create and verify this module.

Changelog

1.4.1

  • Minor bug fix on incorrectly returning the LongPowerFailureLog object

1.4.0

  • Exposing and calculating the datetime of the start of a LongPowerFailure
  • Added the 'reading-raw' event to retrieve the raw data (as a string) that was retrieved from the Smart Meter

1.3.1

  • Added option to control the interval of the emulator mode via an option parameter

1.3.0

  • Added emulator mode for development purposes
  • Extended example with all possible option parameters

1.2.0

  • Upgraded serialport to 4.0.7
  • Serial port is now automatically locked preventing other processes from opening it
  • Added 'connected' event
  • Exposed used serial port name via getSerialPort()

1.1.1

  • Minor bug fix

1.1.0

  • Added option to force a specific port
  • Log more debugging information

1.0.1

  • Updated readme

1.0.0

  • Initial version with full DSMR 4.0 specification implemented

About

Node.js package for reading and parsing data from the P1 port of a Dutch Smart Meter.

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • JavaScript 100.0%