mbpoll

Copyright © 2015 epsilonRT, All rights reserved.

Presentation

mbpoll is a command line utility to communicate with ModBus slave (RTU or TCP).
It uses libmodbus.
This is a multiplatform project, the compilation was tested on GNU Linux x86 and x86_64, Microsoft Windows 7 x86 and GNU Linux ARM 6 (Raspbian).
Although the syntax of these options is very close modpoll proconX program, it is a completely independent project.

mbpoll can:

  • read discrete inputs
  • read and write binary outputs (coil)
  • read input registers
  • read and write output registers (holding register)

The reading and writing registers may be in decimal, hexadecimal or floating single precision.

Installation

The installation instructions are in the INSTALL file.

For example, for a debian system:

  • Install dependencies:

      sudo apt-get update
      sudo apt-get install cmake build-essential
    
  • Generate Makefile with cmake:

      cd mbpoll
      mkdir build
      cd build
      cmake ..
    
  • Compile and install mbpoll:

      make
      sudo make install
    

If you prefer, you can in the place of direct compilation create a package and install it:

    make package
    sudo dpkg -i * .deb

That's all !

Examples

The following command is used to read the input registers 1 and 2 of the slave at address 33 connected through RTU /dev/ttyUSB2 (38400 Bd)


    mbpoll -a 33 -b 38400 -t 3 -r 1 -c 2 /dev/ttyUSB2
    
    mbpoll 0.1-10 - FieldTalk(tm) Modbus(R) Master Simulator
    Copyright (c) 2015 epsilonRT, All rights reserved.
    This software is governed by the CeCILL license <http://www.cecill.info>

    Protocol configuration: Modbus RTU
    Slave configuration...: address = [33]
                            start reference = 1, count = 2
    Communication.........: /dev/ttyUSB2, 38400-8E1 
                            t/o 1.00 s, poll rate 1000 ms
    Data type.............: 16-bit register, input register table

    -- Polling slave 33... Ctrl-C to stop)
    [1]: 	9997
    [2]: 	10034
    -- Polling slave 33... Ctrl-C to stop)
    [1]: 	10007
    [2]: 	10034
    -- Polling slave 33... Ctrl-C to stop)
    [1]: 	10007
    [2]: 	10034
    -- Polling slave 33... Ctrl-C to stop)
    [1]: 	10007
    [2]: 	10034
    ^C--- /dev/ttyUSB2 poll statistics ---
    4 frames transmitted, 4 received, 0 errors, 0.0% frame loss

    everything was closed.
    Have a nice day !

Help

A complete help is available with the -h option:

    usage : mbpoll [ options ] device|host [ writevalues... ] [ options ]

    ModBus Master Simulator. It allows to read and write in ModBus slave registers
                             connected by serial (RTU only) or TCP.

    Arguments :
      device        Serial port when using ModBus RTU protocol
                      COM1, COM2 ...              on Windows
                      /dev/ttyS0, /dev/ttyS1 ...  on Linux
                      /dev/ser1, /dev/ser2 ...    on QNX
      host          Host name or dotted IP address when using ModBus/TCP protocol
      writevalues   List of values to be written.
                    If none specified (default) mbpoll reads data.
                    If negative numbers are provided, it will precede the list of
                    data to be written by two dashes ('--'). for example :
                    mbpoll -t4:int /dev/ttyUSB0 -- 123 -1568 8974 -12
    General options : 
      -m #          mode (rtu or tcp, TCP is default)
      -a #          Slave address (1-255 for rtu, 0-255 for tcp, 1 is default)
                    for reading, it is possible to give an address list
                    separated by commas or colons, for example :
                    -a 32,33,34,36:40 read [32,33,34,36,37,38,39,40]
      -r #          Start reference (1 is default)
      -c #          Number of values to read (1-125, 1 is default)
      -u            Read the description of the type, the current status, and other
                    information specific to a remote device (RTU only)
      -t 0          Discrete output (coil) data type (binary 0 or 1)
      -t 1          Discrete input data type (binary 0 or 1)
      -t 3          16-bit input register data type
      -t 3:hex      16-bit input register data type with hex display
      -t 3:int      32-bit integer data type in input register table
      -t 3:float    32-bit float data type in input register table
      -t 4          16-bit output (holding) register data type (default)
      -t 4:hex      16-bit output (holding) register data type with hex display
      -t 4:int      32-bit integer data type in output (holding) register table
      -t 4:float    32-bit float data type in output (holding) register table
      -0            First reference is 0 (PDU addressing) instead 1
      -1            Poll only once only, otherwise every poll rate interval
      -l #          Poll rate in ms, ( > 100, 1000 is default)
      -o #          Time-out in seconds (0.01 - 10.00, 1.00 s is default)
    Options for ModBus / TCP : 
      -p #          TCP port number (502 is default)
    Options for ModBus RTU : 
      -b #          Baudrate (1200-921600, 19200 is default)
      -d #          Databits (7 or 8, 8 for RTU)
      -s #          Stopbits (1 or 2, 1 is default)
      -P #          Parity (none, even, odd, even is default)
      -4            RS-485 mode

      -h            Print this help summary page
      -V            Print version and exit
      -v            Verbose mode.  Causes mbpoll to print debugging messages about
                    its progress.  This is helpful in debugging connection...

This software is governed by the CeCILL license under French law and abiding by the rules of distribution of free software. You can use, modify and/ or redistribute the software under the terms of the CeCILL license as circulated by CEA, CNRS and INRIA at the following URL "http://www.cecill.info".

As a counterpart to the access to the source code and rights to copy, modify and redistribute granted by the license, users are provided only with a limited warranty and the software's author, the holder of the economic rights, and the successive licensors have only limited liability.

In this respect, the user's attention is drawn to the risks associated with loading, using, modifying and/or developing or reproducing the software by the user in light of its specific status of free software, that may mean that it is complicated to manipulate, and that also therefore means that it is reserved for developers and experienced professionals having in-depth computer knowledge. Users are therefore encouraged to load and test the software's suitability as regards their requirements in conditions enabling the security of their systems and/or data to be ensured and, more generally, to use and operate it in the same conditions as regards security.

The fact that you are presently reading this means that you have had knowledge of the CeCILL license and that you accept its terms.

About

command line utility to communicate with ModBus slave (RTU or TCP)

Resources

License

Unknown, Unknown licenses found

Licenses found

Unknown
LICENCE
Unknown
LICENSE

Stars

Watchers

Forks

Packages

No packages published

Languages

  • C 72.9%
  • Inno Setup 14.9%
  • CMake 9.9%
  • QMake 2.3%