Releases: open-ephys-plugins/neuropixels-pxi
Releases · open-ephys-plugins/neuropixels-pxi
0.7.0
Neuropixels-PXI Plugin v0.7.0
Release notes
New features:
- Add OneBox plugin
- Includes up to 4 probe data streams and one 12-channel ADC stream
- Can run in simulation mode if no OneBox is connected
- Support for DAC outputs coming in next release
- Add full electrode layout for Neuropixels Ultra (switchable) probes
- Add support for new probe types
- Neuropixels 2.0 quad base
- Neuropixels 2.0 single-shank (commercial)
- Update IMRO format to latest spec
- Supports sharing IMRO files with SpikeGLX for all probe types except Neuropixels Ultra
- Exported ProbeInterface JSON files now include all electrodes, not just selected ones
- Add “refresh” button to Neuropixels PXI plugin to rescan for connected probes
- Add progress bar when loading or refreshing plugins
- Add the ability to disable individual probe data streams
- Restrict sync output frequency to 1 Hz
- Show electrode info in tooltip window
Bug fixes:
- Normalize by correct number of ADC bits for Neuropixels 2.0 commercial probes (12 vs. 14). Data recorded with previous plugin versions can be corrected by multiplying by 4.
- Prevent crash when deleting plugin before initialization is complete
- Prevent multiple Neuropix-PXI plugins from connecting to the same device; additional plugins now run in simulation mode
0.6.6
Neuropixels-PXI Plugin v0.6.6
Release Notes
- Add option to set the reference to ground on NP2014 probes
0.6.5
Neuropixels-PXI Plugin v0.6.5
Release Notes
- Add 2 x 192, 4 x 96 and 2 x 2 x 96 electrode configurations for Neuropixels Ultra (Active)
- Enable IMRO file loading for 45 mm NHP probes
0.6.4
Neuropixels-PXI Plugin v0.6.4
Release Notes
- Add option to set the reference to ground on NP2013 probes
- Fix bug with multi-shank probes where it would incorrectly set the reference if the tip ref on shanks 2-4 was selected
- Make scrollbars visible in the Settings Interface
0.6.3
Neuropixels-PXI Plugin v0.6.3
Release Notes
- Update to Neuropixels API version 3.62.1 (adds part number NP1016)
- Add more preset configurations for NHP probes
- Fix crash when sending certain configs using Remote Control
0.6.2
Neuropixels-PXI Plugin v0.6.2
Release Notes
- Add progress bar when using the "apply to all" button, to ensure all probes are updated before subsequent actions are allowed
- Add tab-based interface for browsing between probe settings interfaces
- Electrode layout can be changed by choosing between different presets, in addition to dragging to select
- Fix bug in calculating y-position of UHD probes (y position needed to be divided by the number of columns)
- Adjust layout of settings interface to prevent overlapping text
- Disable copy/paste/apply to all buttons during acquisition
0.6.1
Neuropixels-PXI Plugin v0.6.1
Release Notes
- Display headstage test results in the console rather than a popup window; fixes freezes on plugin initialization when headstage dongle is connected.
0.6.0
Neuropixels-PXI Plugin v0.6.0
Release Notes
- Update to Neuropixels API v3.62 (requires basestation firmware update)
- Add part numbers for commercial 2.0 probes
- Allow basestation firmware updates when no probes are connected
- Send broadcast messages to indicate when timestamp jumps are detected (can happen if PCIe bus is overloaded or the Neuropixels data cable is unplugged)
- Fix bug when overwriting existing IMRO file
0.5.0
Neuropixels-PXI Plugin v0.5.0
Release Notes
- Update to Neuropixels API v3.57 (requires basestation firmware update)
- Add part numbers for commercial NHP probes and NP Ultra Phase 3
- Include
electrode_index
as channel metadata
0.4.1
Neuropixels-PXI Plugin v0.4.1
Release Notes
- Add electrode geometry for Neuropixels Opto
- Fix depth metadata for Neuropixels 2.0 probes (this only affected the LFP Viewer's sorting by depth functionality, not channel selection)
- Enable mouse wheel scrolling in probe display