Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Inaccurate fitted amplitude in rabi_amplitude_msr #656

Closed
aorgazf opened this issue Dec 6, 2023 · 2 comments · Fixed by #659 or #677
Closed

Inaccurate fitted amplitude in rabi_amplitude_msr #656

aorgazf opened this issue Dec 6, 2023 · 2 comments · Fixed by #659 or #677
Labels
bug Something isn't working calibration
Milestone

Comments

@aorgazf
Copy link
Member

aorgazf commented Dec 6, 2023

Hi,
I've noticed that the fit of the amplitude of the pi pulse in rabi_amplitude_msr returns a value that is close, but incorrect.
image
As you may see in the picture, the returned value is 0.436, but the argmax of the fitting curve is 0.466.
I've tried it on several qubits and it always gives a slightly smaller value.

20231205_spinq10q_.zip

@aorgazf aorgazf added bug Something isn't working calibration labels Dec 6, 2023
@andrea-pasquale
Copy link
Contributor

Hi @aorgazf,
thanks for opening the issue.
From the report it seems that you are using an older version of the code.
Do you see the same bug with the latest version of the code?

andrea-pasquale added a commit that referenced this issue Dec 7, 2023
@andrea-pasquale andrea-pasquale added this to the Qibocal 0.0.7 milestone Dec 7, 2023
@aorgazf aorgazf reopened this Dec 20, 2023
@aorgazf
Copy link
Member Author

aorgazf commented Dec 20, 2023

20231220_spinq10q_09_rabi_amp.zip
Hi @andrea-pasquale, I believe the issue is still there:
image

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment