You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Hi,
I've noticed that the fit of the amplitude of the pi pulse in rabi_amplitude_msr returns a value that is close, but incorrect.
As you may see in the picture, the returned value is 0.436, but the argmax of the fitting curve is 0.466.
I've tried it on several qubits and it always gives a slightly smaller value.
Hi @aorgazf,
thanks for opening the issue.
From the report it seems that you are using an older version of the code.
Do you see the same bug with the latest version of the code?
Hi,
I've noticed that the fit of the amplitude of the pi pulse in
rabi_amplitude_msr
returns a value that is close, but incorrect.As you may see in the picture, the returned value is 0.436, but the argmax of the fitting curve is 0.466.
I've tried it on several qubits and it always gives a slightly smaller value.
20231205_spinq10q_.zip
The text was updated successfully, but these errors were encountered: