The APIs in this library (and tool) should not be considered stable!
To install:
$ pip install mficlient
To get started, set your connection information like this:
$ export MFI="https://user:[email protected]:6443"
Then you can run the client, doing something like:
$ mfi dump_sensors Model | Label | Tag | Value | Extra ------------------------------------------------------------------------------- Output 12v | Relay Control | output | 0 | 0.0 Output 24v | Relay | output | 0 | 0.0 Ubiquiti mFi-THS | Temp | temperature | 14.3 | None Input Digital | Garage Door | input | 1 | None Outlet | Heater Control | active_pwr | 5.810242 | 1.0 Ubiquiti mFi-CS | Furnace | amps | 1.0539 | None Ubiquiti mFi-CS | Water Heater | amps | 0.0 | None $ mfi control_device --device 'Heater Control' --state on
Client API example:
>>> c = mficlient.MFiClient('192.168.1.123', 'admin', 'password') >>> p = c.get_port(label='Water Heater Control') >>> p.model 'Outlet' >>> p.value 5.746462 >>> p.tag 'active_pwr' >>> p.data {'rpt_time': 1456258144771, 'mac': 'redacted', 'locked': False, 'label': 'Water Heater Control', 'wattHours': 8001.875, 'y': 222.18320610687024, 'map_id': 'redacted', 'output': 1.0, 'fovrotation': 0, 'active_pwr': 5.746462, 'pf': 0.678653, 'reported_val': 1.0, '_id': 'redacted', 'i_rms': 0.069931, 'fovradius': 10, 'v_rms': 121.082737, 'val_time': 1456258144000, 'port': '1', 'energy_sum': 8001.875, 'wattHoursBase': 0.0, 'tag': 'active_pwr', 'val': 5.746462, 'wh_rpt_time': 1456258144761, 'model': 'Outlet', 'x': 564.8839694656489, 'fovangle': 1.5707963267948966, 'output_val': 1.0} >>> p.control(False)