Available nodes

Dirk-Jan Faber edited this page Nov 1, 2024 · 43 revisions

On this page you find and overview of all possible services and measurements for the available nodes. The edit panel will only show items available in your system. For example a Cerbo CX has 2 relays and thus will show 2 relays to control. An EasySolar-II GX has only one relay and thus will only show one.

You can find more background information on the paths and how to use them here.

Input nodes: AC Charger, AC Load, AC System, Alternator, Battery Monitor, DC-DC, DC Load, DC Source, DC System, Dynamic ESS, Digital Input, ESS, EV Charger, Fuel cell, Generator, GPS, Grid Meter, Inverter, Meteo, Motordrive, Multi RS, Pulsemeter, Pump, PV Inverter, Relay, Settings, Solar Charger, System, Tank Sensor, Temperature Sensor, VE.Bus System
Output nodes: AC Charger Control, AC System Control, Battery Monitor Control, Charger Control, DC-DC Control, Dynamic ESS Control, ESS Control, EV Charger Control, GX Generator Control, Inverter Control, Multi RS Control, Pump Control, PV Inverter Control, Relay Control, Settings Control, Solar Charger Control, VE.Bus System Control
If there are services and paths not covered by the above nodes, there are also 2 custom nodes that allow you to read from and write to all found dbus services and paths.

Input nodes

The input nodes have two selectable inputs: the devices select and measurement select. The available options are dynamically updated based on the data that is actually available on the Venus device.

  • Device select - lists all available devices
  • Measurement select - lists all available device-specific measurements
  • Node label input field - sets a custom label for the node

The measurement unit type is shown in the measurement label in brackets, e.g. Battery voltage (V). In case the data type is enumerated, an appropriate enum legend is shown below the selected option.

If the data type is float, a dropdown for rounding the output appears.

By default the node outputs its value every five seconds. If the only changes is checked, the node will only output on value changes.

In case of an enumerated type, the textual value of the payload is also send out as msg.textvalue. input nodes

AC Charger

The AC charger can be read with this node.

AC Current limit (A), dbus path: /Ac/In/CurrentLimit, type float
AC Current (A), dbus path: /Ac/In/L1/I, type float
AC Power (W), dbus path: /Ac/In/L1/P, type float
High voltage alarm, dbus path: /Alarms/HighVoltage, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Low voltage alarm, dbus path: /Alarms/LowVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Output 1 - current (A), dbus path: /Dc/0/Current, type float
Output 1 - temperature (°C), dbus path: /Dc/0/Temperature, type float
Output 1 - voltage (V), dbus path: /Dc/0/Voltage, type float
Output 2 - current (A), dbus path: /Dc/1/Current, type float
Battery 1 temperature (°C), dbus path: /Dc/1/Temperature, type float
Output 2 - voltage (V), dbus path: /Dc/1/Voltage, type float
Output 3 - current (A), dbus path: /Dc/2/Current, type float
Battery 2 temperature (°C), dbus path: /Dc/2/Temperature, type float
Output 3 - voltage (V), dbus path: /Dc/2/Voltage, type float
Error, dbus path: /ErrorCode, type enum

  • 0 - No error
  • 1 - Err 1: Battery temperature too high
  • 2 - Err 2: Battery voltage too high
  • 3 - Err 3: Battery temperature sensor miswired (+)
  • 4 - Err 3: Battery temperature sensor miswired (-)
  • 5 - Err 5: Battery temperature sensor disconnected
  • 6 - Err 6: Battery voltage sense miswired (+)
  • 7 - Err 7: Battery voltage sense miswired (-)
  • 8 - Err 8: Battery voltage sense disconnected
  • 9 - Err 9: Battery voltage wire losses too high
  • 17 - Err 17: Charger temperature too high
  • 18 - Err 18: Charger over-current
  • 19 - Err 19: Charger current polarity reversed
  • 20 - Err 20: Bulk time limit reached
  • 22 - Err 22: Charger temperature sensor miswired
  • 23 - Err 23: Charger temperature sensor disconnected
  • 34 - Err 34: Input current too high
  • 67 - Err 67: No BMS

Charger on/off, dbus path: /Mode, type enum

  • 1 - On
  • 4 - Off

Relay on the charger, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Charge state, dbus path: /State, type enum

  • 0 - Off
  • 2 - Fault
  • 3 - Bulk
  • 4 - Absorption
  • 5 - Float
  • 6 - Storage
  • 7 - Equalize
  • 11 - Power supply mode
  • 246 - Repeated absorption
  • 247 - Equalize
  • 248 - Battery safe

AC Load

This node allows for AC load monitoring. Measuring can be done by using an energy meter and assigning it the 'ac load' role.

L1 Current (A), dbus path: /Ac/L1/Current, type float
L1 Energy (kWh), dbus path: /Ac/L1/Energy/Forward, type float
L1 Power (W), dbus path: /Ac/L1/Power, type float
L1 Voltage (V AC), dbus path: /Ac/L1/Voltage, type float
L2 Current (A), dbus path: /Ac/L2/Current, type float
L2 Energy (kWh), dbus path: /Ac/L2/Energy/Forward, type float
L2 Power (W), dbus path: /Ac/L2/Power, type float
L2 Voltage (V AC), dbus path: /Ac/L2/Voltage, type float
L3 Current (A), dbus path: /Ac/L3/Current, type float
L3 Energy (kWh), dbus path: /Ac/L3/Energy/Forward, type float
L3 Power (W), dbus path: /Ac/L3/Power, type float
L3 Voltage (V AC), dbus path: /Ac/L3/Voltage, type float
Serial number, dbus path: /Serial, type string

AC System

Managing service for Multi-RS and other future inverter/chargers.

Input voltage phase 1 (V AC), dbus path: /Ac/In/1/L1/V, type float
Input voltage phase 2 (V AC), dbus path: /Ac/In/1/L2/V, type float
Input voltage phase 3 (V AC), dbus path: /Ac/In/1/L3/V, type float
Input current phase 1 (A AC), dbus path: /Ac/In/1/L1/I, type float
Input current phase 2 (A AC), dbus path: /Ac/In/1/L2/I, type float
Input current phase 3 (A AC), dbus path: /Ac/In/1/L3/I, type float
Input power phase 1 (W), dbus path: /Ac/In/1/L1/P, type float
Input power phase 2 (W), dbus path: /Ac/In/1/L2/P, type float
Input power phase 3 (W), dbus path: /Ac/In/1/L3/P, type float
Input frequency (Hz), dbus path: /Ac/In/1/L1/F, type float
Output voltage phase 1 (V AC), dbus path: /Ac/Out/L1/V, type float
Output voltage phase 2 (V AC), dbus path: /Ac/Out/L2/V, type float
Output voltage phase 3 (V AC), dbus path: /Ac/Out/L3/V, type float
Output current phase 1 (A AC), dbus path: /Ac/Out/L1/I, type float
Output current phase 2 (A AC), dbus path: /Ac/Out/L2/I, type float
Output current phase 3 (A AC), dbus path: /Ac/Out/L3/I, type float
Output power phase 1 (W), dbus path: /Ac/Out/L1/P, type float
Output power phase 2 (W), dbus path: /Ac/Out/L2/P, type float
Output power phase 3 (W), dbus path: /Ac/Out/L3/P, type float
Output frequency (Hz), dbus path: /Ac/Out/L1/F, type float
Grid Lost Alarm, dbus path: /Alarms/GridLost, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Phase Rotation Alarm, dbus path: /Alarms/PhaseRotation, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

System state, dbus path: /State, type enum

  • 0 - Off
  • 1 - Low Power
  • 2 - Fault
  • 3 - Bulk
  • 4 - Absorption
  • 5 - Float
  • 6 - Storage
  • 7 - Equalize
  • 8 - Passthru
  • 9 - Inverting
  • 10 - Power assist
  • 11 - Power supply
  • 252 - External control

Alternator

This node allows for monitoring the state of BMVs configured in Monitor Mode and DC meter type is Alternator or an alternator controller which is interfaced to the Venus OS.

High auxiliary voltage alarm, dbus path: /Alarms/HighStarterVoltage, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

High temperature alarm, dbus path: /Alarms/HighTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

High voltage alarm, dbus path: /Alarms/HighVoltage, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low auxiliary voltage alarm, dbus path: /Alarms/LowStarterVoltage, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low temperature alarm, dbus path: /Alarms/LowTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low voltage alarm, dbus path: /Alarms/LowVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Battery current (A), dbus path: /Dc/0/Current, type float
Battery temperature (°C), dbus path: /Dc/0/Temperature, type float
Battery voltage (V), dbus path: /Dc/0/Voltage, type float
Auxiliary voltage (V DC), dbus path: /Dc/1/Voltage, type float
Input voltage (before DC/DC converter) (V DC), dbus path: /Dc/In/V, type float
Input power (W DC), dbus path: /Dc/In/P, type float
Engine speed (RPM), dbus path: /Engine/Speed, type float
Alternator error code, dbus path: /ErrorCode, type enum

  • 12 - High battery temperature
  • 13 - High battery voltage
  • 14 - Low battery voltage
  • 15 - VBat exceeds $CPB
  • 21 - High alternator temperature
  • 22 - Alternator overspeed
  • 24 - Internal error
  • 41 - High field FET temperature
  • 42 - Sensor missing
  • 43 - Low VAlt
  • 44 - High Voltage offset
  • 45 - VAlt exceeds $CPB
  • 53 - Battery instance out of range
  • 54 - Too many BMSes
  • 55 - AEBus fault
  • 56 - Too many Victron devices
  • 91 - BMS lost
  • 92 - Forced idle
  • 201 - DCDC converter fail
  • 51-52 - Battery disconnect request
  • 58-61 - Battery requested disconnection
  • 201-207 - DCDC error

Alternator Field Drive %, dbus path: /FieldDrive, type float
Cumulative amp-hours charged (Ah), dbus path: /History/Cumulative/User/ChargedAh, type float
Total energy produced (kWh), dbus path: /History/EnergyOut, type float
Mode, dbus path: /Mode, type enum

  • 1 - On
  • 4 - Off

Alternator speed (RPM), dbus path: /Speed, type float
Alternator state, dbus path: /State, type enum

  • 0 - Off
  • 2 - Fault
  • 3 - Bulk
  • 4 - Absorption
  • 5 - Float
  • 6 - Storage
  • 7 - Equalize
  • 11 - Psu
  • 252 - External control

Battery Monitor

This node allows for monitoring the state of the battery.

Alarm, dbus path: /Alarms/Alarm, type enum

  • 0 - No alarm
  • 2 - Alarm

Cell Imbalance alarm, dbus path: /Alarms/CellImbalance, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Fuse blown alarm, dbus path: /Alarms/FuseBlown, type enum

  • 0 - No alarm
  • 2 - Alarm

High charge current alarm, dbus path: /Alarms/HighChargeCurrent, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

High charge temperature alarm, dbus path: /Alarms/HighChargeTemperature, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

High discharge current alarm, dbus path: /Alarms/HighDischargeCurrent, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

High fused-voltage alarm, dbus path: /Alarms/HighFusedVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

High internal-temperature alarm, dbus path: /Alarms/HighInternalTemperature, type enum

  • 0 - No alarm
  • 2 - Alarm

High starter-voltage alarm, dbus path: /Alarms/HighStarterVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

High battery temperature alarm, dbus path: /Alarms/HighTemperature, type enum

  • 0 - No alarm
  • 2 - Alarm

High voltage alarm, dbus path: /Alarms/HighVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Internal failure, dbus path: /Alarms/InternalFailure, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Low cell voltage alarm, dbus path: /Alarms/LowCellVoltage, type enum

  • 0 - No alarm
  • 1 - Almost discharged
  • 2 - Alarm

Low charge temperature alarm, dbus path: /Alarms/LowChargeTemperature, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Low fused-voltage alarm, dbus path: /Alarms/LowFusedVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Low state-of-charge alarm, dbus path: /Alarms/LowSoc, type enum

  • 0 - No alarm
  • 2 - Alarm

Low starter-voltage alarm, dbus path: /Alarms/LowStarterVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Low battery temperature alarm, dbus path: /Alarms/LowTemperature, type enum

  • 0 - No alarm
  • 2 - Alarm

Low voltage alarm, dbus path: /Alarms/LowVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Mid-voltage alarm, dbus path: /Alarms/MidVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Balancing, dbus path: /Balancing, type enum

  • 0 - Inactive
  • 1 - Active

Balancer status, dbus path: /Balancer/Status, type enum

  • 0 - Unknown
  • 1 - Balanced
  • 2 - Balancing
  • 3 - Cell imbalance

Capacity (Ah), dbus path: /Capacity, type float
Connection information, dbus path: /ConnectionInformation, type string
Consumed Amphours (Ah), dbus path: /ConsumedAmphours, type float
Battery current (A), dbus path: /Dc/0/Current, type float
Mid-point voltage of the battery bank (V), dbus path: /Dc/0/MidVoltage, type float
Mid-point deviation of the battery bank (%), dbus path: /Dc/0/MidVoltageDeviation, type float
Battery power (W), dbus path: /Dc/0/Power, type float
Battery temperature (°C), dbus path: /Dc/0/Temperature, type float
Battery voltage (V), dbus path: /Dc/0/Voltage, type float
Starter battery voltage (V), dbus path: /Dc/1/Voltage, type float
Diagnostics; 1st last error, dbus path: /Diagnostics/LastErrors/1/Error, type enum

  • 0 - No error
  • 1 - Battery initialization error
  • 2 - No batteries connected
  • 3 - Unknown battery connected
  • 4 - Different battery type
  • 5 - Number of batteries incorrect
  • 6 - Lynx Shunt not found
  • 7 - Battery measure error
  • 8 - Internal calculation error
  • 9 - Batteries in series not ok
  • 10 - Number of batteries incorrect
  • 11 - Hardware error
  • 12 - Watchdog error
  • 13 - Over voltage
  • 14 - Under voltage
  • 15 - Over temperature
  • 16 - Under temperature
  • 17 - Hardware fault
  • 18 - Standby shutdown
  • 19 - Pre-charge charge error
  • 20 - Safety contactor check error
  • 21 - Pre-charge discharge error
  • 22 - ADC error
  • 23 - Slave error
  • 24 - Slave warning
  • 25 - Pre-charge error
  • 26 - Safety contactor error
  • 27 - Over current
  • 28 - Slave update failed
  • 29 - Slave update unavailable
  • 30 - Calibration data lost
  • 31 - Settings invalid
  • 32 - BMS cable
  • 33 - Reference failure
  • 34 - Wrong system voltage
  • 35 - Pre-charge timeout

Diagnostics; 1st last error timestamp, dbus path: /Diagnostics/LastErrors/1/Time, type float
Diagnostics; 2nd last error, dbus path: /Diagnostics/LastErrors/2/Error, type float
Diagnostics; 2nd last error timestamp, dbus path: /Diagnostics/LastErrors/2/Time, type float
Diagnostics; 3rd last error, dbus path: /Diagnostics/LastErrors/3/Error, type float
Diagnostics; 3rd last error timestamp, dbus path: /Diagnostics/LastErrors/3/Time, type float
Diagnostics; 4th last error, dbus path: /Diagnostics/LastErrors/4/Error, type float
Diagnostics; 4th last error timestamp, dbus path: /Diagnostics/LastErrors/4/Time, type float
Diagnostics; shutdowns due to error (count), dbus path: /Diagnostics/ShutDownsDueError, type float
Error, dbus path: /ErrorCode, type enum

  • 0 - No error
  • 1 - Battery initialization error
  • 2 - No batteries connected
  • 3 - Unknown battery connected
  • 4 - Different battery type
  • 5 - Number of batteries incorrect
  • 6 - Lynx Shunt not found
  • 7 - Battery measure error
  • 8 - Internal calculation error
  • 9 - Batteries in series not ok
  • 10 - Number of batteries incorrect
  • 11 - Hardware error
  • 12 - Watchdog error
  • 13 - Over voltage
  • 14 - Under voltage
  • 15 - Over temperature
  • 16 - Under temperature
  • 17 - Hardware fault
  • 18 - Standby shutdown
  • 19 - Pre-charge charge error
  • 20 - Safety contactor check error
  • 21 - Pre-charge discharge error
  • 22 - ADC error
  • 23 - Slave error
  • 24 - Slave warning
  • 25 - Pre-charge error
  • 26 - Safety contactor error
  • 27 - Over current
  • 28 - Slave update failed
  • 29 - Slave update unavailable
  • 30 - Calibration data lost
  • 31 - Settings invalid
  • 32 - BMS cable
  • 33 - Reference failure
  • 34 - Wrong system voltage
  • 35 - Pre-charge timeout

SmartLithium error flag: Communication, dbus path: /Errors/SmartLithium/Communication, type float
SmartLithium error flag: Invalid configuration, dbus path: /Errors/SmartLithium/InvalidConfiguration, type float
SmartLithium error flag: Battery number, dbus path: /Errors/SmartLithium/NrOfBatteries, type float
SmartLithium error flag: Voltage, dbus path: /Errors/SmartLithium/Voltage, type float
Automatic syncs (count), dbus path: /History/AutomaticSyncs, type float
Average discharge (Ah), dbus path: /History/AverageDischarge, type float
Charge cycles (count), dbus path: /History/ChargeCycles, type float
Charged Energy (kWh), dbus path: /History/ChargedEnergy, type float
Deepest discharge (Ah), dbus path: /History/DeepestDischarge, type float
Discharged Energy (kWh), dbus path: /History/DischargedEnergy, type float
Full discharges (count), dbus path: /History/FullDischarges, type float
High fused-voltage alarms (count), dbus path: /History/HighFusedVoltageAlarms, type float
High starter voltage alarms (count), dbus path: /History/HighStarterVoltageAlarms, type float
High voltage alarms (count), dbus path: /History/HighVoltageAlarms, type float
Last discharge (Ah), dbus path: /History/LastDischarge, type float
Low fused-voltage alarms (count), dbus path: /History/LowFusedVoltageAlarms, type float
Low starter voltage alarms (count), dbus path: /History/LowStarterVoltageAlarms, type float
Low voltage alarms (count), dbus path: /History/LowVoltageAlarms, type float
History; Max cell-voltage (V DC), dbus path: /History/MaximumCellVoltage, type float
Maximum fused voltage (V DC), dbus path: /History/MaximumFusedVoltage, type float
Maximum starter voltage (V DC), dbus path: /History/MaximumStarterVoltage, type float
Maximum voltage (V DC), dbus path: /History/MaximumVoltage, type float
History; Min cell-voltage (V DC), dbus path: /History/MinimumCellVoltage, type float
Minimum fused voltage (V DC), dbus path: /History/MinimumFusedVoltage, type float
Minimum starter voltage (V DC), dbus path: /History/MinimumStarterVoltage, type float
Minimum voltage (V DC), dbus path: /History/MinimumVoltage, type float
Time since last full charge (seconds), dbus path: /History/TimeSinceLastFullCharge, type float
Total Ah drawn (Ah), dbus path: /History/TotalAhDrawn, type float
Min discharge voltage (V DC), dbus path: /Info/BatteryLowVoltage, type float
CCL - Charge Current Limit (A), dbus path: /Info/MaxChargeCurrent, type float
CVL - Charge Voltage Limit (V), dbus path: /Info/MaxChargeVoltage, type float
DCL - Discharge Current Limit (A), dbus path: /Info/MaxDischargeCurrent, type float
ATC (Allow to Charge), dbus path: /Io/AllowToCharge, type enum

  • 0 - No
  • 1 - Yes

ATD (Allow to Discharge), dbus path: /Io/AllowToDischarge, type enum

  • 0 - No
  • 1 - Yes

IO; external relay, dbus path: /Io/ExternalRelay, type enum

  • 0 - Inactive
  • 1 - Active

Mode, dbus path: /Mode, type enum

  • 3 - On
  • 252 - Standby

Relay status, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

State of charge (%), dbus path: /Soc, type float
State of health (%), dbus path: /Soh, type float
State, dbus path: /State, type enum

  • 0 - Initializing (Wait start)
  • 1 - Initializing (before boot)
  • 2 - Initializing (Before boot delay)
  • 3 - Initializing (Wait boot)
  • 4 - Initializing
  • 5 - Initializing (Measure battery voltage)
  • 6 - Initializing (Calculate battery voltage)
  • 7 - Initializing (Wait bus voltage)
  • 8 - Initializing (Wait for lynx shunt)
  • 9 - Running
  • 10 - Error
  • 11 - Unused
  • 12 - Shutdown
  • 13 - Slave updating
  • 14 - Standby
  • 15 - Going to run
  • 16 - Pre-charging
  • 17 - Contactor check

System; batteries parallel (count), dbus path: /System/BatteriesParallel, type float
System; batteries series (count), dbus path: /System/BatteriesSeries, type float
System; ID of module with highest cell voltage, dbus path: /System/MaxVoltageCellId, type string
Maximum cell temperature (°C), dbus path: /System/MaxCellTemperature, type float
System; maximum cell voltage (V DC), dbus path: /System/MaxCellVoltage, type float
System; ID of module with highest cell temperature, dbus path: /System/MaxTemperatureCellId, type string
System; ID of module with lowest cell voltage, dbus path: /System/MinVoltageCellId, type string
Minimum cell temperature (°C), dbus path: /System/MinCellTemperature, type float
System; minimum cell voltage (V DC), dbus path: /System/MinCellVoltage, type float
System; ID of module with lowest cell temperature, dbus path: /System/MinTemperatureCellId, type string
System; number of batteries (count), dbus path: /System/NrOfBatteries, type float
System; number of cells per battery (count), dbus path: /System/NrOfCellsPerBattery, type float
Number of modules blocking charge, dbus path: /System/NrOfModulesBlockingCharge, type integer
Number of modules blocking discharge, dbus path: /System/NrOfModulesBlockingDischarge, type integer
Number of offline modules, dbus path: /System/NrOfModulesOffline, type integer
Number of online modules, dbus path: /System/NrOfModulesOnline, type integer
System-switch, dbus path: /SystemSwitch, type enum

  • 0 - Disabled
  • 1 - Enabled

For monitoring the state of the built-in contactor.

Time to go (s), dbus path: /TimeToGo, type float

DC-DC

This node allows for monitoring the state of an Orion XS.

/Dc/0/Current (A DC), dbus path: /Dc/0/Current, type float
/Dc/0/Temperature (Degrees celsius), dbus path: /Dc/0/Temperature, type float
/Dc/0/Voltage (V DC), dbus path: /Dc/0/Voltage, type float
/Dc/In/V (V DC), dbus path: /Dc/In/V, type float
/Dc/In/P (W), dbus path: /Dc/In/P, type float
/ErrorCode, dbus path: /ErrorCode, type enum

  • 0 - No error
  • 1 - Battery temperature too high
  • 2 - Battery voltage too high
  • 3 - Battery temperature sensor miswired (+)
  • 4 - Battery temperature sensor miswired (-)
  • 5 - Battery temperature sensor disconnected
  • 6 - Battery voltage sense miswired (+)
  • 7 - Battery voltage sense miswired (-)
  • 8 - Battery voltage sense disconnected
  • 9 - Battery voltage wire losses too high
  • 17 - Charger temperature too high
  • 18 - Charger over-current
  • 19 - Charger current polarity reversed
  • 20 - Bulk time limit reached
  • 22 - Charger temperature sensor miswired
  • 23 - Charger temperature sensor disconnected
  • 34 - Input current too high

/FirmwareVersion, dbus path: /FirmwareVersion, type float
/History/Cumulative/User/ChargedAh (Ah), dbus path: /History/Cumulative/User/ChargedAh, type float
/ProductId, dbus path: /ProductId, type float
/State, dbus path: /State, type enum

  • 0 - Off
  • 2 - Fault
  • 3 - Bulk
  • 4 - Absorption
  • 5 - Float
  • 6 - Storage
  • 7 - Equalize

DC Load

This node allows for monitoring the state of BMVs configured in Monitor Mode and DC meter type is a load.

High starter-voltage alarm, dbus path: /Alarms/HighStarterVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

High battery temperature alarm, dbus path: /Alarms/HighTemperature, type enum

  • 0 - No alarm
  • 2 - Alarm

High voltage alarm, dbus path: /Alarms/HighVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Low starter-voltage alarm, dbus path: /Alarms/LowStarterVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Low battery temperature alarm, dbus path: /Alarms/LowTemperature, type enum

  • 0 - No alarm
  • 2 - Alarm

Low voltage alarm, dbus path: /Alarms/LowVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Battery current (A), dbus path: /Dc/0/Current, type float
Battery temperature (°C), dbus path: /Dc/0/Temperature, type float
Battery voltage (V), dbus path: /Dc/0/Voltage, type float
Starter battery voltage (V), dbus path: /Dc/1/Voltage, type float
Total energy consumed (kWh), dbus path: /History/EnergyIn, type float
Relay status, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

DC Source

This node allows for monitoring the state of Battery Monitor Victron devices (BMV's) configured in Monitor Mode and DC meter type is a source.

High starter-voltage alarm, dbus path: /Alarms/HighStarterVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

High battery temperature alarm, dbus path: /Alarms/HighTemperature, type enum

  • 0 - No alarm
  • 2 - Alarm

High voltage alarm, dbus path: /Alarms/HighVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Low starter-voltage alarm, dbus path: /Alarms/LowStarterVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Low battery temperature alarm, dbus path: /Alarms/LowTemperature, type enum

  • 0 - No alarm
  • 2 - Alarm

Low voltage alarm, dbus path: /Alarms/LowVoltage, type enum

  • 0 - No alarm
  • 2 - Alarm

Battery current (A), dbus path: /Dc/0/Current, type float
Battery temperature (°C), dbus path: /Dc/0/Temperature, type float
Battery voltage (V), dbus path: /Dc/0/Voltage, type float
Starter battery voltage (V), dbus path: /Dc/1/Voltage, type float
Total energy produced (kWh), dbus path: /History/EnergyOut, type float
Relay status, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

DC System

DC system input node is a DC measurement for loads in your system.

High auxiliary voltage alarm, dbus path: /Alarms/HighStarterVoltage, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

High temperature alarm, dbus path: /Alarms/HighTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

High voltage alarm, dbus path: /Alarms/HighVoltage, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Low auxiliary voltage alarm, dbus path: /Alarms/LowStarterVoltage, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low temperature alarm, dbus path: /Alarms/LowTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low voltage alarm, dbus path: /Alarms/LowVoltage, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Battery current (A), dbus path: /Dc/0/Current, type float
Battery temperature (°C), dbus path: /Dc/0/Temperature, type float
Battery voltage (V DC), dbus path: /Dc/0/Voltage, type float
Auxiliary voltage (V DC), dbus path: /Dc/1/Voltage, type float
Total energy consumed (kWh), dbus path: /History/EnergyIn, type float
Total energy produced (kWh), dbus path: /History/EnergyOut, type float

Dynamic ESS

Dynamic ESS input node.

Is Dynamic ESS available, dbus path: /DynamicEss/Available, type enum

  • 0 - System is not capable of doing DynamicEss
  • 1 - System is capable of doing DynamicEss

Error, dbus path: /DynamicEss/ErrorCode, type enum

  • 0 - No error
  • 1 - No ESS
  • 2 - ESS mode
  • 3 - No matching schedule
  • 4 - SOC low
  • 5 - Battery capacity not configured

Active restrictions, dbus path: /DynamicEss/Restrictions, type enum

  • 0 - No restrictions between battery and the grid
  • 1 - Grid to battery energy flow is restricted
  • 2 - Battery to grid energy flow is restricted
  • 3 - No energy flow between battery and grid

Used strategy for current time slot, dbus path: /DynamicEss/Strategy, type enum

  • 0 - Target SOC
  • 1 - Self-consumption

The set target SOC for this time slot (%), dbus path: /DynamicEss/TargetSoc, type float
Battery capacity (kWh), dbus path: /Settings/DynamicEss/BatteryCapacity, type float
Full battery charge duration (hour), dbus path: /Settings/DynamicEss/FullChargeDuration, type float
Full battery charge interval (day), dbus path: /Settings/DynamicEss/FullChargeInterval, type float
Dynamic ESS mode, dbus path: /Settings/DynamicEss/Mode, type enum

  • 0 - Off
  • 1 - Auto
  • 4 - Node-RED

Allow grid feed-in during schedule 0, dbus path: /Settings/DynamicEss/Schedule/0/AllowGridFeedIn, type enum

  • 0 - Not allowed
  • 1 - Allowed

Duration for schedule 0 (Seconds), dbus path: /Settings/DynamicEss/Schedule/0/Duration, type float
Active restrictions for schedule 0, dbus path: /Settings/DynamicEss/Schedule/0/Restrictions, type enum

  • 0 - No restrictions between battery and the grid
  • 1 - Grid to battery energy flow is restricted
  • 2 - Battery to grid energy flow is restricted
  • 3 - No energy flow between battery and grid

Target SOC for schedule 0 (%), dbus path: /Settings/DynamicEss/Schedule/0/Soc, type float
Used strategy for schedule 0, dbus path: /Settings/DynamicEss/Schedule/0/Strategy, type enum

  • 0 - Target SOC
  • 1 - Self-consumption

Allow grid feed-in during schedule 1, dbus path: /Settings/DynamicEss/Schedule/1/AllowGridFeedIn, type enum

  • 0 - Not allowed
  • 1 - Allowed

Duration for schedule 1 (Seconds), dbus path: /Settings/DynamicEss/Schedule/1/Duration, type float
Active restrictions for schedule 1, dbus path: /Settings/DynamicEss/Schedule/1/Restrictions, type enum

  • 0 - No restrictions between battery and the grid
  • 1 - Grid to battery energy flow is restricted
  • 2 - Battery to grid energy flow is restricted
  • 3 - No energy flow between battery and grid

Target SOC for schedule 1 (%), dbus path: /Settings/DynamicEss/Schedule/1/Soc, type float
Used strategy for schedule 1, dbus path: /Settings/DynamicEss/Schedule/1/Strategy, type enum

  • 0 - Target SOC
  • 1 - Self-consumption

Allow grid feed-in during schedule 2, dbus path: /Settings/DynamicEss/Schedule/2/AllowGridFeedIn, type enum

  • 0 - Not allowed
  • 1 - Allowed

Duration for schedule 2 (Seconds), dbus path: /Settings/DynamicEss/Schedule/2/Duration, type float
Active restrictions for schedule 2, dbus path: /Settings/DynamicEss/Schedule/2/Restrictions, type enum

  • 0 - No restrictions between battery and the grid
  • 1 - Grid to battery energy flow is restricted
  • 2 - Battery to grid energy flow is restricted
  • 3 - No energy flow between battery and grid

Target SOC for schedule 2 (%), dbus path: /Settings/DynamicEss/Schedule/2/Soc, type float
Used strategy for schedule 2, dbus path: /Settings/DynamicEss/Schedule/2/Strategy, type enum

  • 0 - Target SOC
  • 1 - Self-consumption

Allow grid feed-in during schedule 3, dbus path: /Settings/DynamicEss/Schedule/3/AllowGridFeedIn, type enum

  • 0 - Not allowed
  • 1 - Allowed

Duration for schedule 3 (Seconds), dbus path: /Settings/DynamicEss/Schedule/3/Duration, type float
Active restrictions for schedule 3, dbus path: /Settings/DynamicEss/Schedule/3/Restrictions, type enum

  • 0 - No restrictions between battery and the grid
  • 1 - Grid to battery energy flow is restricted
  • 2 - Battery to grid energy flow is restricted
  • 3 - No energy flow between battery and grid

Target SOC for schedule 3 (%), dbus path: /Settings/DynamicEss/Schedule/3/Soc, type float
Used strategy for schedule 3, dbus path: /Settings/DynamicEss/Schedule/3/Strategy, type enum

  • 0 - Target SOC
  • 1 - Self-consumption

Digital Input

With this node it is possible to read the digital inputs from the Venus device. The node only shows the enabled digital inputs, so first make sure to enable the input from the Venus OS GUI (Settings -> I/O -> digital inputs) for the desired readout.Depending on the selected type of input, different measurements become available.Also see the section on digital inputs in the Cerbo GX manual.

Pulse meter aggregate, dbus path: /Aggregate, type float
Pulse meter count, dbus path: /Count, type float
Digital input alarm, dbus path: /Alarm, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Digital input count, dbus path: /Count, type float
Digital input state, dbus path: /State, type enum

  • 0 - low
  • 1 - high
  • 2 - off
  • 3 - on
  • 4 - no
  • 5 - yes
  • 6 - open
  • 7 - closed
  • 8 - ok
  • 9 - alarm
  • 10 - running
  • 11 - stopped

Digital input type, dbus path: /Type, type enum

  • 0 - Disabled
  • 1 - Pulse meter
  • 2 - Door sensor
  • 3 - Bilge pump
  • 4 - Bilge alarm
  • 5 - Burglar alarm
  • 6 - Smoke alarm
  • 7 - Fire alarm
  • 8 - CO2 alarm
  • 9 - Generator
  • 10 - Generic input

ESS

This node gives information on the energy storage system (ESS).

Maximum battery cell temperature, dbus path: /System/MaxCellTemperature, type integer
Maximum battery cell voltage, dbus path: /System/MaxCellVoltage, type integer
Minimum battery cell temperature, dbus path: /System/MinCellTemperature, type integer
Minimum battery cell voltage, dbus path: /System/MinCellVoltage, type integer
Number of modules blocking charge, dbus path: /System/NrOfModulesBlockingCharge, type integer
Number of modules blocking discharge, dbus path: /System/NrOfModulesBlockingDischarge, type integer
Number of offline modules, dbus path: /System/NrOfModulesOffline, type integer
Number of online modules, dbus path: /System/NrOfModulesOnline, type integer
Disable charge, dbus path: /Hub4/DisableCharge, type enum

  • 0 - No
  • 1 - Yes

Disable feed-in, dbus path: /Hub4/DisableFeedIn, type enum

  • 0 - No
  • 1 - Yes

Feed in overvoltage, dbus path: /Hub4/DoNotFeedInOvervoltage, type enum

  • 0 - Yes
  • 1 - No

AC Power L1 setpoint (W), dbus path: /Hub4/L1/AcPowerSetpoint, type integer
Maximum overvoltage feed-in power L1 (W), dbus path: /Hub4/L1/MaxFeedInPower, type integer
AC Power L2 setpoint (W), dbus path: /Hub4/L2/AcPowerSetpoint, type integer
Maximum overvoltage feed-in power L2 (W), dbus path: /Hub4/L2/MaxFeedInPower, type integer
Maximum overvoltage feed-in power L3 (W), dbus path: /Hub4/L3/MaxFeedInPower, type integer
AC Power L3 setpoint (W), dbus path: /Hub4/L3/AcPowerSetpoint, type integer
Disable PV inverter, dbus path: /PvInverter/Disable, type enum

  • 0 - No
  • 1 - Yes

VE.Bus system restart, dbus path: /SystemReset, type enum

  • 0 - No
  • 1 - Yes

Grid set-point (W), dbus path: /Settings/CGwacs/AcPowerSetPoint, type integer
Minimum Discharge SOC (%), dbus path: /Settings/CGwacs/BatteryLife/MinimumSocLimit, type integer
Schedule 1: Self-consumption above limit, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/0/AllowDischarge, type enum

  • 0 - Yes
  • 1 - No

Schedule 1: Day, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/0/Day, type enum

  • 0 - Sunday
  • 1 - Monday
  • 2 - Tuesday
  • 3 - Wednesday
  • 4 - Thursday
  • 5 - Friday
  • 6 - Saturday
  • 7 - Every day
  • 8 - Weekdays
  • 9 - Weekends

A negative value means that the schedule has been de-activated.

Schedule 1: Duration (seconds), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/0/Duration, type integer
Schedule 1: State of charge (%), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/0/Soc, type integer
Schedule 1: Start (seconds after midnight), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/0/Start, type integer
Schedule 2: Self-consumption above limit, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/1/AllowDischarge, type enum
  • 0 - Yes
  • 1 - No

Schedule 2: Day, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/1/Day, type enum

  • 0 - Sunday
  • 1 - Monday
  • 2 - Tuesday
  • 3 - Wednesday
  • 4 - Thursday
  • 5 - Friday
  • 6 - Saturday
  • 7 - Every day
  • 8 - Weekdays
  • 9 - Weekends

A negative value means that the schedule has been de-activated.

Schedule 2: Duration (seconds), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/1/Duration, type integer
Schedule 2: State of charge (%), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/1/Soc, type integer
Schedule 2: Start (seconds after midnight), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/1/Start, type integer
Schedule 3: Self-consumption above limit, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/2/AllowDischarge, type enum
  • 0 - Yes
  • 1 - No

Schedule 3: Day, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/2/Day, type enum

  • 0 - Sunday
  • 1 - Monday
  • 2 - Tuesday
  • 3 - Wednesday
  • 4 - Thursday
  • 5 - Friday
  • 6 - Saturday
  • 7 - Every day
  • 8 - Weekdays
  • 9 - Weekends

A negative value means that the schedule has been de-activated.

Schedule 3: Duration (seconds), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/2/Duration, type integer
Schedule 3: State of charge (%), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/2/Soc, type integer
Schedule 3: Start (seconds after midnight), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/2/Start, type integer
Schedule 4: Self-consumption above limit, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/3/AllowDischarge, type enum
  • 0 - Yes
  • 1 - No

Schedule 4: Day, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/3/Day, type enum

  • 0 - Sunday
  • 1 - Monday
  • 2 - Tuesday
  • 3 - Wednesday
  • 4 - Thursday
  • 5 - Friday
  • 6 - Saturday
  • 7 - Every day
  • 8 - Weekdays
  • 9 - Weekends

A negative value means that the schedule has been de-activated.

Schedule 4: Duration (seconds), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/3/Duration, type integer
Schedule 4: State of charge (%), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/3/Soc, type integer
Schedule 4: Start (seconds after midnight), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/3/Start, type integer
Schedule 5: Self-consumption above limit, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/4/AllowDischarge, type enum
  • 0 - Yes
  • 1 - No

Schedule 5: Day, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/4/Day, type enum

  • 0 - Sunday
  • 1 - Monday
  • 2 - Tuesday
  • 3 - Wednesday
  • 4 - Thursday
  • 5 - Friday
  • 6 - Saturday
  • 7 - Every day
  • 8 - Weekdays
  • 9 - Weekends

Writing a negative value to the path will de-activate the schedule. Schedule 5: Duration (seconds), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/4/Duration, type integer
Schedule 5: State of charge (%), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/4/Soc, type integer
Schedule 5: Start (seconds after midnight), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/4/Start, type integer
ESS state, dbus path: /Settings/CGwacs/BatteryLife/State, type enum

  • 1 - BatteryLife enabled (GUI controlled)
  • 2 - Optimized Mode /w BatteryLife: self consumption
  • 3 - Optimized Mode /w BatteryLife: self consumption, SoC exceeds 85%
  • 4 - Optimized Mode /w BatteryLife: self consumption, SoC at 100%
  • 5 - Optimized Mode /w BatteryLife: SoC below dynamic SoC limit
  • 6 - Optimized Mode /w BatteryLife: SoC has been below SoC limit for more than 24 hours. Charging the battery (5A)
  • 7 - Optimized Mode /w BatteryLife: Inverter/Charger is in sustain mode
  • 8 - Optimized Mode /w BatteryLife: recharging, SoC dropped by 5% or more below the minimum SoC
  • 9 - 'Keep batteries charged' mode is enabled
  • 10 - Optimized mode w/o BatteryLife: self consumption, SoC at or above minimum SoC
  • 11 - Optimized mode w/o BatteryLife: self consumption, SoC is below minimum SoC
  • 12 - Optimized mode w/o BatteryLife: recharging, SoC dropped by 5% or more below minimum SoC

ESS mode, dbus path: /Settings/CGwacs/Hub4Mode, type enum

  • 1 - Optimized mode or 'keep batteries charged' and phase compensation enabled
  • 2 - Optimized mode or 'keep batteries charged' and phase compensation disabled
  • 3 - External control

Max charge power (W), dbus path: /Settings/CGwacs/MaxChargePower, type integer

Not used with DVCC.

Max inverter power (W), dbus path: /Settings/CGwacs/MaxDischargePower, type integer
Feed excess DC-coupled PV into grid, dbus path: /Settings/CGwacs/OvervoltageFeedIn, type enum
  • 0 - Don’t feed excess DC-tied PV into grid
  • 1 - Feed excess DC-tied PV into the grid

Don’t feed excess AC-coupled PV into grid, dbus path: /Settings/CGwacs/PreventFeedback, type enum

  • 0 - Feed excess AC-tied PV into grid
  • 1 - Don’t feed excess AC-tied PV into the grid

Grid metering, dbus path: /Settings/CGwacs/RunWithoutGridMeter, type enum

  • 0 - External meter
  • 1 - Inverter/Charger

DVCC Charge current limit (A), dbus path: /Settings/SystemSetup/MaxChargeCurrent, type float
DVCC Maximum charge voltage (V), dbus path: /Settings/SystemSetup/MaxChargeVoltage, type float
Active SOC limit (%), dbus path: /Control/ActiveSocLimit, type integer

EV Charger

The EV charger input node is for reading from the EV Charging Station.Also see here for more information.

Energy consumed by charger (kWh), dbus path: /Ac/Energy/Forward, type float
L1 Power (W), dbus path: /Ac/L1/Power, type float
L2 Power (W), dbus path: /Ac/L2/Power, type float
L3 Power (W), dbus path: /Ac/L3/Power, type float
Total power (W), dbus path: /Ac/Power, type float
Charging time (seconds), dbus path: /ChargingTime, type float
Charge current (A), dbus path: /Current, type float
Display, dbus path: /EnableDisplay, type enum

  • 0 - Locked
  • 1 - Unlocked

Firmware version, dbus path: /FirmwareVersion, type float
Maximum charge current (A), dbus path: /MaxCurrent, type float
Mode, dbus path: /Mode, type enum

  • 0 - Manual
  • 1 - Auto
  • 2 - Schedule

Model, dbus path: /Model, type float
Product ID, dbus path: /ProductId, type float
Serial, dbus path: /Serial, type string
Set charge current (manual mode) (A), dbus path: /SetCurrent, type float
Start/stop charging (manual mode), dbus path: /StartStop, type enum

  • 0 - Stop
  • 1 - Start

Status, dbus path: /Status, type enum

  • 0 - Disconnected
  • 1 - Connected
  • 2 - Charging
  • 3 - Charged
  • 4 - Waiting for sun
  • 5 - Waiting for RFID
  • 6 - Waiting for start
  • 7 - Low SOC
  • 8 - Ground test error
  • 9 - Welded contacts test error
  • 10 - CP input test error (shorted)
  • 11 - Residual current detected
  • 12 - Undervoltage detected
  • 13 - Overvoltage detected
  • 14 - Overheating detected
  • 15 - Reserved
  • 16 - Reserved
  • 17 - Reserved
  • 18 - Reserved
  • 19 - Reserved
  • 20 - Charging limit
  • 21 - Start charging
  • 22 - Switching to 3 phase
  • 23 - Switching to 1 phase
  • 24 - Stop charging

Fuel cell

See https://github.com/victronenergy/venus/wiki/dbus#fuelcell for more information.

High voltage alarm, dbus path: /Alarms/HighVoltage, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

High auxiliary voltage alarm, dbus path: /Alarms/HighStarterVoltage, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

High temperature alarm, dbus path: /Alarms/HighTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low auxiliary voltage alarm, dbus path: /Alarms/LowStarterVoltage, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low temperature alarm, dbus path: /Alarms/LowTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low voltage alarm, dbus path: /Alarms/LowVoltage, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Battery current (A), dbus path: /Dc/0/Current, type float
Battery temperature (°C), dbus path: /Dc/0/Temperature, type float
Battery voltage (V DC), dbus path: /Dc/0/Voltage, type float
Auxiliary voltage (V DC), dbus path: /Dc/1/Voltage, type float
Total energy produced (kWh), dbus path: /History/EnergyOut, type float

Generator

Generator input node for relay controlled and Fischer Panda generators.In order to use the relay for controlling a generator, make sure to set the relay to Generator via the (remote) console first.The Generator start/stop dropdown is for the generic generator. It can activate a relay, but also, in case of Fischer panda, a generator directly via D-Bus.The other option(s) are for generator data like voltages, RPM, oil pressure etcetera.Also see here for more information.

Generator not detected at AC input alarm, dbus path: /Alarms/NoGeneratorAtAcIn, type enum

  • 0 - No alarm
  • 2 - Alarm

Auto start enabled/disabled, dbus path: /AutoStartEnabled, type enum

  • 0 - Autostart disabled
  • 1 - Autostart enabled

Generator remote error, dbus path: /Error, type enum

  • 0 - No Error
  • 1 - Remote disabled
  • 2 - Remote fault

Manual Start, dbus path: /ManualStart, type enum

  • 0 - Stop generator
  • 1 - Start generator

Quiet hours active, dbus path: /QuietHours, type enum

  • 0 - Quiet hours inactive
  • 1 - Quiet hours active

Condition that started the generator, dbus path: /RunningByConditionCode, type enum

  • 0 - Stopped
  • 1 - Manual
  • 2 - TestRun
  • 3 - LossOfComms
  • 4 - Soc
  • 5 - AcLoad
  • 6 - BatteryCurrent
  • 7 - BatteryVoltage
  • 8 - InverterTemperature
  • 9 - InverterOverload
  • 10 - StopOnAc1

Runtime in seconds (seconds), dbus path: /Runtime, type float
Service countdown counter (seconds until next generator service), dbus path: /ServiceCounter, type float
Generator start/stop state, dbus path: /State, type enum

  • 0 - Stopped
  • 1 - Running
  • 2 - Warm-up
  • 3 - Cool-down
  • 4 - Stopping
  • 10 - Error

Run time since last test run (seconds), dbus path: /TestRunIntervalRuntime, type float
Today's run time (seconds), dbus path: /TodayRunTime, type float
AC Frequency (Hz), dbus path: /Ac/Frequency, type float
Phase 1 current (A AC), dbus path: /Ac/L1/Current, type float
Phase 1 frequency (Hz), dbus path: /Ac/L1/Frequency, type float
Phase 1 power (W), dbus path: /Ac/L1/Power, type float
Phase 1 voltage (V AC), dbus path: /Ac/L1/Voltage, type float
Phase 2 current (A AC), dbus path: /Ac/L2/Current, type float
Phase 2 frequency (Hz), dbus path: /Ac/L2/Frequency, type float
Phase 2 power (W), dbus path: /Ac/L2/Power, type float
Phase 2 voltage (V AC), dbus path: /Ac/L2/Voltage, type float
Phase 3 current (A AC), dbus path: /Ac/L3/Current, type float
Phase 3 frequency (Hz), dbus path: /Ac/L3/Frequency, type float
Phase 3 power (W), dbus path: /Ac/L3/Power, type float
Phase 3 voltage (V AC), dbus path: /Ac/L3/Voltage, type float
The number of phases (1, 2 or 3), dbus path: /NrOfPhases, type float
Remote start mode, dbus path: /RemoteStartModeEnabled, type enum

  • 0 - Disabled
  • 1 - Enabled

DC output 1 - Current (A), dbus path: /Dc/0/Current, type float
DC output 1 - Power (W), dbus path: /Dc/0/Power, type float
DC output 1 - Voltage (V), dbus path: /Dc/0/Voltage, type float
Engine coolant temperature (°C), dbus path: /Engine/CoolantTemperature, type float
Engine exhaust temperature (°C), dbus path: /Engine/ExaustTemperature, type float
Oil temperature (°C), dbus path: /Engine/OilTemperature, type float
Engine load (%), dbus path: /Engine/Load, type float
Oil pressure (kPa), dbus path: /Engine/OilPressure, type float
Engine operating hours (s), dbus path: /Engine/OperatingHours, type float
Engine speed (RPM), dbus path: /Engine/Speed, type float
Nr of starts (absolute count), dbus path: /Engine/Starts, type float
Engine winding temperature (°C), dbus path: /Engine/WindingTemperature, type float
Generator specific error code 0, dbus path: /Error/0/Id, type string
Generator specific error code 1, dbus path: /Error/1/Id, type string
Generator specific error code 2, dbus path: /Error/2/Id, type string
Generator specific error code 3, dbus path: /Error/3/Id, type string
Generator specific error code 4, dbus path: /Error/4/Id, type string
Generator specific error code 5, dbus path: /Error/5/Id, type string
Generator specific error code 6, dbus path: /Error/6/Id, type string
Generator specific error code 7, dbus path: /Error/7/Id, type string
Error, dbus path: /ErrorCode, type enum

  • 0 - No error
  • 1 - AC voltage L1 too low
  • 2 - AC frequency L1 too low
  • 3 - AC current too low
  • 4 - AC power too low
  • 5 - Emergency stop
  • 6 - Servo current too low
  • 7 - Oil pressure too low
  • 8 - Engine temperature too low
  • 9 - Winding temperature too low
  • 10 - Exhaust temperature too low
  • 13 - Starter current too low
  • 14 - Glow current too low
  • 15 - Glow current too low
  • 16 - Fuel holding magnet current too low
  • 17 - Stop solenoid hold coil current too low
  • 18 - Stop solenoid pull coil current too low
  • 19 - Optional DC out current too low
  • 20 - 5V output voltage too low
  • 21 - Boost output current too low
  • 22 - Panel supply current too high
  • 25 - Starter battery voltage too low
  • 26 - Startup aborted (rotation too low)
  • 28 - Rotation too low
  • 29 - Power contactor current too low
  • 30 - AC voltage L2 too low
  • 31 - AC frequency L2 too low
  • 32 - AC current L2 too low
  • 33 - AC power L2 too low
  • 34 - AC voltage L3 too low
  • 35 - AC frequency L3 too low
  • 36 - AC current L3 too low
  • 37 - AC power L3 too low
  • 62 - Fuel temperature too low
  • 63 - Fuel level too low
  • 65 - AC voltage L1 too high
  • 66 - AC frequency too high
  • 67 - AC current too high
  • 68 - AC power too high
  • 70 - Servo current too high
  • 71 - Oil pressure too high
  • 72 - Engine temperature too high
  • 73 - Winding temperature too high
  • 74 - Exhaust temperature too low
  • 77 - Starter current too low
  • 78 - Glow current too high
  • 79 - Glow current too high
  • 80 - Fuel holding magnet current too high
  • 81 - Stop solenoid hold coil current too high
  • 82 - Stop solenoid pull coil current too high
  • 83 - Optional DC out current too high
  • 84 - 5V output voltage too high
  • 85 - Boost output current too high
  • 89 - Starter battery voltage too high
  • 90 - Startup aborted (rotation too high)
  • 92 - Rotation too high
  • 93 - Power contactor current too high
  • 94 - AC voltage L2 too high
  • 95 - AC frequency L2 too high
  • 96 - AC current L2 too high
  • 97 - AC power L2 too high
  • 98 - AC voltage L3 too high
  • 99 - AC frequency L3 too high
  • 100 - AC current L3 too high
  • 101 - AC power L3 too high
  • 126 - Fuel temperature too high
  • 127 - Fuel level too high
  • 130 - Lost control unit
  • 131 - Lost panel
  • 132 - Service needed
  • 133 - Lost 3-phase module
  • 134 - Lost AGT module
  • 135 - Synchronization failure
  • 137 - Intake airfilter
  • 139 - Lost sync. module
  • 140 - Load-balance failed
  • 141 - Sync-mode deactivated
  • 142 - Engine controller
  • 148 - Rotating field wrong
  • 149 - Fuel level sensor lost
  • 150 - Init failed
  • 151 - Watchdog
  • 152 - Out: winding
  • 153 - Out: exhaust
  • 154 - Out: Cyl. head
  • 155 - Inverter over temperature
  • 156 - Inverter overload
  • 157 - Inverter communication lost
  • 158 - Inverter sync failed
  • 159 - CAN communication lost
  • 160 - L1 overload
  • 161 - L2 overload
  • 162 - L3 overload
  • 163 - DC overload
  • 164 - DC overvoltage
  • 165 - Emergency stop
  • 166 - No connection

Heatsink temperature (°C), dbus path: /HeatsinkTemperature, type float
Generator model, dbus path: /ProductId, type float
Starter voltage (V DC), dbus path: /StarterVoltage, type float
Status, dbus path: /StatusCode, type enum

  • 0 - Standby
  • 1 - Startup 1
  • 2 - Startup 2
  • 3 - Startup 3
  • 4 - Startup 4
  • 5 - Startup 5
  • 6 - Startup 6
  • 7 - Startup 7
  • 8 - Running
  • 9 - Stopping
  • 10 - Error

DC current (DC A), dbus path: /Dc/0/Current, type float
DC current (DC A), dbus path: /Dc/0/Current, type float
Engine coolant temperature (Degrees celsius), dbus path: /Engine/CoolantTemperature, type float
Engine exhaust temperature (Degrees celsius), dbus path: /Engine/ExaustTemperature, type float
Engine load (%), dbus path: /Engine/Load, type float
Oil pressure (kPa), dbus path: /Engine/OilPressure, type float
Engine oil temperature (Degrees celsius), dbus path: /Engine/OilTemperature, type float
Engine oil temperature (Seconds), dbus path: /Engine/OperatingHours, type float
Heatsink temperature (RPM), dbus path: /Engine/Speed, type float
Internal winding temperature (Degrees celsius), dbus path: /Engine/WindingTemperature, type float
Generator specific error code 0, dbus path: /Error/0/Id, type string
Generator specific error code 1, dbus path: /Error/1/Id, type string
Generator specific error code 2, dbus path: /Error/2/Id, type string
Generator specific error code 3, dbus path: /Error/3/Id, type string
Generator specific error code 4, dbus path: /Error/4/Id, type string
Generator specific error code 5, dbus path: /Error/5/Id, type string
Generator specific error code 6, dbus path: /Error/6/Id, type string
Generator specific error code 7, dbus path: /Error/7/Id, type string
Heatsink temperature (Degrees celsius), dbus path: /HeatsinkTemperature, type float
Starter battery voltage (DC V), dbus path: /StarterVoltage, type float

GPS

GPS information can be obtained with this node. For an example usage see the location based scheduling example.

Altitude (m), dbus path: /Altitude, type float
Course (Deg), dbus path: /Course, type float
Fix, dbus path: /Fix, type integer
Number of satellites, dbus path: /NrOfSatellites, type integer
Latitude (LAT), dbus path: /Position/Latitude, type float
Longitude (LNG), dbus path: /Position/Longitude, type float
Speed (m/s), dbus path: /Speed, type float

Grid Meter

This node gives allows for monitoring the grid. See also energy meters accessories.

Frequency (Hz), dbus path: /Ac/Frequency, type float
Total Forward Energy (bought) (kWh), dbus path: /Ac/Energy/Forward, type float
Total Reverse Energy (sold) (kWh), dbus path: /Ac/Energy/Reverse, type float
L1 Current (A), dbus path: /Ac/L1/Current, type float
L1 Forward energy (bought) (kWh), dbus path: /Ac/L1/Energy/Forward, type float
L1 Reverse energy (sold) (kWh), dbus path: /Ac/L1/Energy/Reverse, type float
L1 Power (W), dbus path: /Ac/L1/Power, type float
L1 Voltage (V), dbus path: /Ac/L1/Voltage, type float
L2 Current (A), dbus path: /Ac/L2/Current, type float
L2 Forward energy (bought) (kWh), dbus path: /Ac/L2/Energy/Forward, type float
L2 Reverse energy (sold) (kWh), dbus path: /Ac/L2/Energy/Reverse, type float
L2 Power (W), dbus path: /Ac/L2/Power, type float
L2 Voltage (V), dbus path: /Ac/L2/Voltage, type float
L3 Current (A), dbus path: /Ac/L3/Current, type float
L3 Forward energy (bought) (kWh), dbus path: /Ac/L3/Energy/Forward, type float
L3 Reverse energy (sold) (kWh), dbus path: /Ac/L3/Energy/Reverse, type float
L3 Power (W), dbus path: /Ac/L3/Power, type float
L3 Voltage (V), dbus path: /Ac/L3/Voltage, type float
Power (W), dbus path: /Ac/Power, type float
Serial, dbus path: /Serial, type string

Inverter

This node is for reading from an inverter.

Output current (A), dbus path: /Ac/Out/L1/I, type float
Output power (W AC), dbus path: /Ac/Out/L1/P, type float
Output voltage (V), dbus path: /Ac/Out/L1/V, type float
High temperature alarm, dbus path: /Alarms/HighTemperature, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

High battery voltage alarm, dbus path: /Alarms/HighVoltage, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

High AC-Out voltage alarm, dbus path: /Alarms/HighVoltageAcOut, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Low SOC alarm, dbus path: /Alarms/LowSoc, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Low temperature alarm, dbus path: /Alarms/LowTemperature, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Low battery voltage alarm, dbus path: /Alarms/LowVoltage, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Low AC-Out voltage alarm, dbus path: /Alarms/LowVoltageAcOut, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Overload alarm, dbus path: /Alarms/Overload, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Ripple alarm, dbus path: /Alarms/Ripple, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Battery current (A DC), dbus path: /Dc/0/Current, type float
Input voltage (V), dbus path: /Dc/0/Voltage, type float
Energy from battery to AC-out (kWh), dbus path: /Energy/InverterToAcOut, type float
Energy from AC-out to battery (kWh), dbus path: /Energy/OutToInverter, type float
Energy from solar to AC-out (kWh), dbus path: /Energy/SolarToAcOut, type float
Energy from solar to battery (kWh), dbus path: /Energy/SolarToBattery, type float
Firmware version, dbus path: /FirmwareVersion, type float
Maximum power for today on tracker 0 (W), dbus path: /History/Daily/0/Pv/0/MaxPower, type float
Yield today for today on tracker 0 (kWh), dbus path: /History/Daily/0/Pv/0/Yield, type float
Maximum power for today on tracker 1 (W), dbus path: /History/Daily/0/Pv/1/MaxPower, type float
Yield today for today on tracker 1 (kWh), dbus path: /History/Daily/0/Pv/1/Yield, type float
Maximum power for today on tracker 2 (W), dbus path: /History/Daily/0/Pv/2/MaxPower, type float
Yield today for today on tracker 2 (kWh), dbus path: /History/Daily/0/Pv/2/Yield, type float
Maximum power for today on tracker 3 (W), dbus path: /History/Daily/0/Pv/3/MaxPower, type float
Yield today for today on tracker 3 (kWh), dbus path: /History/Daily/0/Pv/3/Yield, type float
Maximum power for yesterday on tracker 0 (W), dbus path: /History/Daily/1/Pv/0/MaxPower, type float
Yield today for yesterday on tracker 0 (kWh), dbus path: /History/Daily/1/Pv/0/Yield, type float
Maximum power for yesterday on tracker 1 (W), dbus path: /History/Daily/1/Pv/1/MaxPower, type float
Yield today for yesterday on tracker 1 (kWh), dbus path: /History/Daily/1/Pv/1/Yield, type float
Maximum power for yesterday on tracker 2 (W), dbus path: /History/Daily/1/Pv/2/MaxPower, type float
Yield today for yesterday on tracker 2 (kWh), dbus path: /History/Daily/1/Pv/2/Yield, type float
Maximum power for yesterday on tracker 3 (W), dbus path: /History/Daily/1/Pv/3/MaxPower, type float
Yield today for yesterday on tracker 3 (kWh), dbus path: /History/Daily/1/Pv/3/Yield, type float
Mode, dbus path: /Mode, type enum

  • 2 - Inverter on
  • 4 - Off
  • 5 - Low Power/ECO

Inverter model, dbus path: /ProductId, type float
MPP operation mode tracker 1, dbus path: /Pv/0/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

PV power for tracker 0 (W), dbus path: /Pv/0/P, type float
PV voltage for tracker 0 (V DC), dbus path: /Pv/0/V, type float
MPP operation mode tracker 2, dbus path: /Pv/1/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

PV power for tracker 1 (W), dbus path: /Pv/1/P, type float
PV voltage for tracker 1 (V DC), dbus path: /Pv/1/V, type float
MPP operation mode tracker 3, dbus path: /Pv/2/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

PV power for tracker 2 (W), dbus path: /Pv/2/P, type float
PV voltage for tracker 2 (V DC), dbus path: /Pv/2/V, type float
MPP operation mode tracker 4, dbus path: /Pv/3/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

PV power for tracker 3 (W), dbus path: /Pv/3/P, type float
PV voltage for tracker 3 (V DC), dbus path: /Pv/3/V, type float
PV voltage (for single tracker units) (V DC), dbus path: /Pv/V, type float
Relay state, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

State, dbus path: /State, type enum

  • 0 - Off
  • 1 - Low Power
  • 2 - Fault
  • 9 - Inverting

Meteo

input-meteo node allows for Solar Irradiance, Temperature and Wind Speed Sensors measuring.More information and supported devices can be found in the manual.

Sensor cell temperature (°C), dbus path: /CellTemperature, type float
External temperature (°C), dbus path: /ExternalTemperature, type float
External temperature – second sensor (Degrees celsius), dbus path: /ExternalTemperature2, type float
Solar Irradiance (W/m^2), dbus path: /Irradiance, type float
Wind speed (m/s), dbus path: /WindSpeed, type float

Motordrive

This is the motordrive input node. See https://bitbucket.org/oceanvolt/dbus_motordrive/src for more information.

Controller Temperature (°C), dbus path: /Controller/Temperature, type float
Motor RPM (RPM), dbus path: /Motor/RPM, type float
Motor temperature (°C), dbus path: /Motor/Temperature, type float
Controller DC Current (A DC), dbus path: /Dc/0/Current, type float
Controller DC Power (W), dbus path: /Dc/0/Power, type float
Controller DC Voltage (V DC), dbus path: /Dc/0/Voltage, type float

Multi RS

This is the Multi RS input node.

Active AC input, dbus path: /Ac/ActiveIn/ActiveInput, type enum

  • 0 - AC Input 1
  • 1 - AC Input 2
  • 240 - Disconnected

Ac input 1 current limit (A), dbus path: /Ac/In/1/CurrentLimit, type float
Input frequency phase 1 (Hz), dbus path: /Ac/In/1/L1/F, type float
Input current phase 1 (A AC), dbus path: /Ac/In/1/L1/I, type float
Input power phase 1 (W), dbus path: /Ac/In/1/L1/P, type float
Input voltage phase 1 (V AC), dbus path: /Ac/In/1/L1/V, type float
Input current phase 2 (A AC), dbus path: /Ac/In/1/L2/I, type float
Input power phase 2 (W), dbus path: /Ac/In/1/L2/P, type float
Input voltage phase 2 (V AC), dbus path: /Ac/In/1/L2/V, type float
Input current phase 3 (A AC), dbus path: /Ac/In/1/L3/I, type float
Input power phase 3 (W), dbus path: /Ac/In/1/L3/P, type float
Input voltage phase 3 (V AC), dbus path: /Ac/In/1/L3/V, type float
AC input 1 source type, dbus path: /Ac/In/1/Type, type enum

  • 0 - Unused
  • 1 - Grid
  • 2 - Genset
  • 3 - Shore

Ac input 2 current limit (A), dbus path: /Ac/In/2/CurrentLimit, type float
AC input 2 source type, dbus path: /Ac/In/2/Type, type enum

  • 0 - Unused
  • 1 - Grid
  • 2 - Genset
  • 3 - Shore

Phase count (count), dbus path: /Ac/NumberOfPhases, type float
Output frequency phase 1 (Hz), dbus path: /Ac/Out/L1/F, type float
Output current phase 1 (A AC), dbus path: /Ac/Out/L1/I, type float
Output power phase 1 (W), dbus path: /Ac/Out/L1/P, type float
Output voltage phase 1 (V AC), dbus path: /Ac/Out/L1/V, type float
Output current phase 2 (A AC), dbus path: /Ac/Out/L2/I, type float
Output power phase 2 (W), dbus path: /Ac/Out/L2/P, type float
Output voltage phase 2 (V AC), dbus path: /Ac/Out/L2/V, type float
Output current phase 3 (A AC), dbus path: /Ac/Out/L3/I, type float
Output power phase 3 (W), dbus path: /Ac/Out/L3/P, type float
Output voltage phase 3 (V AC), dbus path: /Ac/Out/L3/V, type float
Temperature alarm, dbus path: /Alarms/HighTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

High voltage alarm, dbus path: /Alarms/HighVoltage, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

High AC-Out voltage alarm, dbus path: /Alarms/HighVoltageAcOut, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low SOC alarm, dbus path: /Alarms/LowSoc, type enum

  • 0 - No alarm
  • 1 - Warning
  • 2 - Alarm

Low battery temperature alarm, dbus path: /Alarms/LowTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low voltage alarm, dbus path: /Alarms/LowVoltage, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low AC-Out voltage alarm, dbus path: /Alarms/LowVoltageAcOut, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Overload alarm, dbus path: /Alarms/Overload, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

High DC ripple alarm, dbus path: /Alarms/Ripple, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Short Circuit Alarm, dbus path: /Alarms/ShortCircuit, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Battery current (A DC), dbus path: /Dc/0/Current, type float
Battery temperature (°C), dbus path: /Dc/0/Temperature, type float
Battery voltage (V DC), dbus path: /Dc/0/Voltage, type float
Energy from AC-in-1 to AC-out (kWh), dbus path: /Energy/AcIn1ToAcOut, type float
Energy from AC-in-1 to battery (kWh), dbus path: /Energy/AcIn1ToInverter, type float
Energy from AC-in-2 to AC-out (kWh), dbus path: /Energy/AcIn2ToAcOut, type float
Energy from AC-in-2 to battery (kWh), dbus path: /Energy/AcIn2ToInverter, type float
Energy from AC-out to AC-in-1 (kWh), dbus path: /Energy/AcOutToAcIn1, type float
Energy from AC-out to AC-in-2 (kWh), dbus path: /Energy/AcOutToAcIn2, type float
Energy from battery to AC-in-1 (kWh), dbus path: /Energy/InverterToAcIn1, type float
Energy from battery to AC-in-2 (kWh), dbus path: /Energy/InverterToAcIn2, type float
Energy from battery to AC-out (kWh), dbus path: /Energy/InverterToAcOut, type float
Energy from AC-out to battery (kWh), dbus path: /Energy/OutToInverter, type float
Energy from solar to AC-in-1 (kWh), dbus path: /Energy/SolarToAcIn1, type float
Energy from solar to AC-in-2 (kWh), dbus path: /Energy/SolarToAcIn2, type float
Energy from solar to AC-out (kWh), dbus path: /Energy/SolarToAcOut, type float
Energy from solar to battery (kWh), dbus path: /Energy/SolarToBattery, type float
Error code, dbus path: /ErrorCode, type enum

  • 0 - No error
  • 1 - Battery temperature too high
  • 2 - Battery voltage too high
  • 3 - Battery temperature sensor miswired (+)
  • 4 - Battery temperature sensor miswired (-)
  • 5 - Battery temperature sensor disconnected
  • 6 - Battery voltage sense miswired (+)
  • 7 - Battery voltage sense miswired (-)
  • 8 - Battery voltage sense disconnected
  • 9 - Battery voltage wire losses too high
  • 17 - Charger temperature too high
  • 18 - Charger over-current
  • 19 - Charger current polarity reversed
  • 20 - Bulk time limit reached
  • 22 - Charger temperature sensor miswired
  • 23 - Charger temperature sensor disconnected
  • 34 - Input current too high

ESS power setpoint (W), dbus path: /Ess/AcPowerSetpoint, type float
Disable Feed-in, dbus path: /Ess/DisableFeedIn, type enum

  • 0 - Feed-in enabled
  • 1 - Feed-in disabled

Disable charge, dbus path: /Ess/DisableCharge, type enum

  • 0 - Charge enabled
  • 1 - Charge disabled

Sustain active, dbus path: /Ess/Sustain, type enum

  • 0 - Sustain inactive
  • 1 - Sustain active

Maximum charge power today (W), dbus path: /History/Daily/0/MaxPower, type float
Maximum charge power today for tracker 0 (W), dbus path: /History/Daily/0/Pv/0/MaxPower, type float
Yield today for tracker 0 (kWh), dbus path: /History/Daily/0/Pv/0/Yield, type float
Maximum charge power today for tracker 1 (W), dbus path: /History/Daily/0/Pv/1/MaxPower, type float
Yield today for tracker 1 (kWh), dbus path: /History/Daily/0/Pv/1/Yield, type float
Maximum charge power today for tracker 2 (W), dbus path: /History/Daily/0/Pv/2/MaxPower, type float
Yield today for tracker 2 (kWh), dbus path: /History/Daily/0/Pv/2/Yield, type float
Yield today for tracker 3 (kWh), dbus path: /History/Daily/0/Pv/3/Yield, type float
Maximum charge power today for tracker 3 (W), dbus path: /History/Daily/0/Pv/3/MaxPower, type float
Yield today (kWh), dbus path: /History/Daily/0/Yield, type float
Maximum charge power yesterday (W), dbus path: /History/Daily/1/MaxPower, type float
Maximum charge power yesterday tracker 0 (W), dbus path: /History/Daily/1/Pv/0/MaxPower, type float
Yield yesterday for tracker 0 (kWh), dbus path: /History/Daily/1/Pv/0/Yield, type float
Maximum charge power yesterday tracker 1 (W), dbus path: /History/Daily/1/Pv/1/MaxPower, type float
Yield yesterday for tracker 1 (kWh), dbus path: /History/Daily/1/Pv/1/Yield, type float
Maximum charge power yesterday tracker 2 (W), dbus path: /History/Daily/1/Pv/2/MaxPower, type float
Yield yesterday for tracker 2 (kWh), dbus path: /History/Daily/1/Pv/2/Yield, type float
Maximum charge power yesterday tracker 3 (W), dbus path: /History/Daily/1/Pv/3/MaxPower, type float
Yield yesterday for tracker 3 (kWh), dbus path: /History/Daily/1/Pv/3/Yield, type float
Yield yesterday (kWh), dbus path: /History/Daily/1/Yield, type float
MPP operation mode, dbus path: /MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

MPP operation mode tracker 1, dbus path: /Pv/0/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

PV power for tracker 0 (W), dbus path: /Pv/0/P, type float
PV voltage for tracker 0 (V DC), dbus path: /Pv/0/V, type float
MPP operation mode tracker 2, dbus path: /Pv/1/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

PV power for tracker 1 (W), dbus path: /Pv/1/P, type float
PV voltage for tracker 1 (V DC), dbus path: /Pv/1/V, type float
MPP operation mode tracker 3, dbus path: /Pv/2/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

PV power for tracker 2 (W), dbus path: /Pv/2/P, type float
PV voltage for tracker 2 (V DC), dbus path: /Pv/2/V, type float
MPP operation mode tracker 4, dbus path: /Pv/3/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

PV power for tracker 3 (W), dbus path: /Pv/3/P, type float
PV voltage for tracker 3 (V DC), dbus path: /Pv/3/V, type float
PV voltage (V DC), dbus path: /Pv/V, type float
Relay on the Multi RS, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

ESS Minimum SOC Limit (%), dbus path: /Settings/Ess/MinimumSocLimit, type float
ESS mode, dbus path: /Settings/Ess/Mode, type enum

  • 0 - self-consumption (battery-life)
  • 1 - self-consumption
  • 2 - Keep charged
  • 3 - External control

Battery State of Charge (%), dbus path: /Soc, type float
Inverter/Charger state, dbus path: /State, type enum

  • 0 - Off
  • 1 - Low Power
  • 2 - Fault
  • 3 - Bulk
  • 4 - Absorption
  • 5 - Float
  • 6 - Storage
  • 7 - Equalize
  • 8 - Passthru
  • 9 - Inverting
  • 10 - Power assist
  • 11 - Power supply
  • 252 - External control

Switch position, dbus path: /Mode, type enum

  • 1 - Charger Only
  • 2 - Inverter Only
  • 3 - On
  • 4 - Off

PV power (W), dbus path: /Yield/Power, type float
User yield (kWh), dbus path: /Yield/User, type float

Pulsemeter

This node is for obtaining information from a pulsemeter. In order to use this, set a digital input to Pulse meter first via the GUI (Under I/O -> Digital inputs).

Count (number of pulses on meter), dbus path: /Count, type float
Aggregate (measured value) (m3), dbus path: /Aggregate, type float

Pump

Node for getting pump information.

Pump State, dbus path: /State, type enum

  • 0 - Stopped
  • 1 - Running

Auto start enabled, dbus path: /Settings/Pump0/AutoStartEnabled, type enum

  • 0 - Disabled
  • 1 - Enabled

Mode, dbus path: /Settings/Pump0/Mode, type enum

  • 0 - Auto
  • 1 - On
  • 2 - Off

Start value (%), dbus path: /Settings/Pump0/StartValue, type float
Stop value (%), dbus path: /Settings/Pump0/StopValue, type float

PV Inverter

This node is for obtaining information from the PV inverter.

Total energy (kWh), dbus path: /Ac/Energy/Forward, type float
L1 Current (A), dbus path: /Ac/L1/Current, type float
L1 Energy (kWh), dbus path: /Ac/L1/Energy/Forward, type float
L1 Power (W), dbus path: /Ac/L1/Power, type float
Power limit (W), dbus path: /Ac/PowerLimit, type float
L1 Voltage (V), dbus path: /Ac/L1/Voltage, type float
L2 Current (A), dbus path: /Ac/L2/Current, type float
L2 Energy (kWh), dbus path: /Ac/L2/Energy/Forward, type float
L2 Power (W), dbus path: /Ac/L2/Power, type float
L2 Voltage (V), dbus path: /Ac/L2/Voltage, type float
L3 Current (A), dbus path: /Ac/L3/Current, type float
L3 Energy (kWh), dbus path: /Ac/L3/Energy/Forward, type float
L3 Power (W), dbus path: /Ac/L3/Power, type float
L3 Voltage (V), dbus path: /Ac/L3/Voltage, type float
Maximum Power Capacity (kW), dbus path: /Ac/MaxPower, type float
Total Power (W), dbus path: /Ac/Power, type float
Error, dbus path: /ErrorCode, type enum

  • 0 - No Error

Position, dbus path: /Position, type enum

  • 0 - AC input 1
  • 1 - AC output
  • 2 - AC input 2

Serial, dbus path: /Serial, type string
Status, dbus path: /StatusCode, type enum

  • 0 - Startup 0
  • 1 - Startup 1
  • 2 - Startup 2
  • 3 - Startup 3
  • 4 - Startup 4
  • 5 - Startup 5
  • 6 - Startup 6
  • 7 - Running
  • 8 - Standby
  • 9 - Boot loading
  • 10 - Error
  • 11 - Running (MPPT)
  • 12 - Running (Throttled)

Relay

input-relay node reads the state of the relay(s) of the Venus device.

Venus relay 1 state, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Venus relay 2 state, dbus path: /Relay/1/State, type enum

  • 0 - Open
  • 1 - Closed

Venus relay 3 state, dbus path: /Relay/2/State, type enum

  • 0 - Open
  • 1 - Closed

Venus relay 4 state, dbus path: /Relay/3/State, type enum

  • 0 - Open
  • 1 - Closed

Relay on the charger, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Relay status, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Relay on the charger, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Relay state, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Relay on the Multi RS, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Relay on the charger, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Settings

With this node several settings can be read. Currently the focus is mainly on the Carlo Gavazzi Wired AC Sensors (cgwacs).

AC export current limit (A), dbus path: /Settings/CGwacs/AcExportLimit, type float
AC import current limit (A), dbus path: /Settings/CGwacs/AcImportLimit, type float
Mode for peakshaving, dbus path: /Settings/CGwacs/AlwaysPeakShave, type enum

  • 0 - Above minimum SOC only
  • 1 - Always

ESS max charge current (fractional) (%), dbus path: /Settings/CGwacs/MaxChargePercentage, type float
ESS max discharge current (fractional) (%), dbus path: /Settings/CGwacs/MaxDischargePercentage, type float
Maximum System Grid Feed In (W), dbus path: /Settings/CGwacs/MaxFeedInPower, type integer

  • -1: No limit
  • >=0: limited system feed-in

Applies to DC-coupled and AC-coupled feed-in.

ESS BatteryLife SoC limit (read only) (%), dbus path: /Settings/CGwacs/BatteryLife/SocLimit, type float
Enable status LEDs, dbus path: /Settings/LEDs/Enable, type enum
  • 0 - Disabled
  • 1 - Enabled

AC input 1 source (for VE.Bus inverter/chargers), dbus path: /Settings/SystemSetup/AcInput1, type enum

  • 0 - Unused
  • 1 - Grid
  • 2 - Genset
  • 3 - Shore

AC input 2 source (for VE.Bus inverter/chargers), dbus path: /Settings/SystemSetup/AcInput2, type enum

  • 0 - Unused
  • 1 - Grid
  • 2 - Genset
  • 3 - Shore

System name, dbus path: /Settings/SystemSetup/SystemName, type string
Grid limiting status, dbus path: /PvPowerLimiterActive, type enum

  • 0 - Feed-in limiting is inactive
  • 1 - Feed-in limiting is active

Applies to both AC-coupled and DC-coupled limiting.

Solar Charger

Information from the Solar charger can be read with this node.

Alarm, dbus path: /Alarms/Alarm, type enum

  • 0 - No alarm
  • 2 - Alarm

High batt. voltage alarm, dbus path: /Alarms/HighVoltage, type enum

  • 0 - No alarm
  • 1 - Alarm

Low batt. voltage alarm, dbus path: /Alarms/LowVoltage, type enum

  • 0 - No alarm
  • 1 - Alarm

Battery current (A), dbus path: /Dc/0/Current, type float
Battery temperature (°C), dbus path: /Dc/0/Temperature, type float
Battery voltage (V), dbus path: /Dc/0/Voltage, type float
Equalization pending, dbus path: /Equalization/Pending, type enum

  • 0 - No
  • 1 - Yes
  • 2 - Error
  • 3 - Unavailable- Unknown

Equalization time remaining (seconds), dbus path: /Equalization/TimeRemaining, type float
Error code, dbus path: /ErrorCode, type enum

  • 0 - No error
  • 1 - #1 - Battery temperature too high
  • 2 - #2 - Battery voltage too high
  • 3 - #3 - Battery temperature sensor miswired (+)
  • 4 - #4 - Battery temperature sensor miswired (-)
  • 5 - #5 - Battery temperature sensor disconnected
  • 6 - #6 - Battery voltage sense miswired (+)
  • 7 - #7 - Battery voltage sense miswired (-)
  • 8 - #8 - Battery voltage sense disconnected
  • 9 - #9 - Battery voltage wire losses too high
  • 10 - #10 - Battery voltage too low
  • 11 - #11 - Battery ripple voltage on terminals too high
  • 12 - #12 - Battery low state of charge
  • 13 - #13 - Battery mid-point voltage issue
  • 14 - #14 - Battery temperature too low
  • 17 - #17 - Charger temperature too high
  • 18 - #18 - Charger over-current
  • 19 - #19 - Charger current polarity reversed
  • 20 - #20 - Max Bulk-time exceeded
  • 21 - #21 - Charger current sensor issue
  • 22 - #22 - Temperature sensor miswired
  • 23 - #23 - Charger temperature sensor disconnected
  • 24 - #24 - Charger internal fan not detected
  • 25 - #25 - Charger internal fan over-current
  • 26 - #26 - Charger terminal overheated
  • 27 - #27 - Charger short circuit
  • 28 - #28 - Charger issue with power stage
  • 29 - #29 - Over-charge protection
  • 31 - #31 - Input voltage out of range
  • 32 - #32 - Input voltage too low
  • 33 - #33 - Input voltage too high
  • 34 - #34 - PV over current
  • 35 - #35 - Input excessive power
  • 36 - #36 - Input polarity issue
  • 37 - #37 - Input voltage absent (mains removed, fuse blown?)
  • 38 - #38 - Input shutdown due to battery over-voltage
  • 39 - #39 - Input shutdown due to battery over-voltage
  • 40 - #40 - Internal failure (PV Input failed to shutdown)
  • 41 - #41 - Inverter shutdown (panel isolation resistance too low)
  • 42 - #42 - Inverter shutdown (ground current too high: >30mA)
  • 43 - #43 - Inverter shutdown (voltage over ground relay too high)
  • 50 - #50 - Inverter overload (iit protection)
  • 51 - #51 - Inverter temperature too high
  • 52 - #52 - Inverter excessive current
  • 53 - #53 - Inverter dc level (internal dc rail voltage)
  • 54 - #54 - Inverter ac level (output voltage not ok)
  • 55 - #55 - Inverter dc fail (dc on output)
  • 56 - #56 - Inverter ac fail (shape wrong)*/
  • 57 - #57 - Inverter ac on output (inverter only)
  • 58 - #58 - Inverter bridge fault (hardware signal)
  • 59 - #59 - ACIN1 relay test fault
  • 60 - #60 - ACIN2 relay test fault
  • 65 - #65 - Device disappeared during parallel operation (broken cable?)
  • 66 - #66 - Incompatible device encountered for parallel operation (e.g. old firmware/different settings)
  • 67 - #67 - No BMS
  • 68 - #68 - Network misconfigured
  • 113 - #113 - Non-volatile storage write error
  • 114 - #114 - CPU temperature to high
  • 115 - #115 - CAN/SCI communication lost (when critical)
  • 116 - #116 - Calibration data lost
  • 117 - #117 - Incompatible firmware encountered
  • 118 - #118 - Incompatible hardware encountered
  • 119 - #119 - Settings data lost
  • 120 - #120 - Reference voltage failure
  • 121 - #121 - Tester fail
  • 122 - #122 - Non-volatile history data invalid/corrupted
  • 200 - #200 - Internal error
  • 201 - #201 - Internal error
  • 203 - #203 - Internal error
  • 205 - #205 - Internal error
  • 212 - #212 - Internal error
  • 215 - #215 - Internal error

Maximum charge power today (W), dbus path: /History/Daily/0/MaxPower, type float
Maximum charge power today for tracker 0 (W), dbus path: /History/Daily/0/Pv/0/MaxPower, type float
Yield today for tracker 0 (kWh), dbus path: /History/Daily/0/Pv/0/Yield, type float
Maximum charge power today for tracker 1 (W), dbus path: /History/Daily/0/Pv/1/MaxPower, type float
Yield today for tracker 1 (kWh), dbus path: /History/Daily/0/Pv/1/Yield, type float
Maximum charge power today for tracker 2 (W), dbus path: /History/Daily/0/Pv/2/MaxPower, type float
Yield today for tracker 2 (kWh), dbus path: /History/Daily/0/Pv/2/Yield, type float
Maximum charge power today for tracker 3 (W), dbus path: /History/Daily/0/Pv/3/MaxPower, type float
Yield today for tracker 3 (kWh), dbus path: /History/Daily/0/Pv/3/Yield, type float
Yield today (kWh), dbus path: /History/Daily/0/Yield, type float
Maximum charge power yesterday (W), dbus path: /History/Daily/1/MaxPower, type float
Maximum charge power yesterday tracker 0 (W), dbus path: /History/Daily/1/Pv/0/MaxPower, type float
Yield yesterday for tracker 0 (kWh), dbus path: /History/Daily/1/Pv/0/Yield, type float
Maximum charge power yesterday tracker 1 (W), dbus path: /History/Daily/1/Pv/1/MaxPower, type float
Yield yesterday for tracker 1 (kWh), dbus path: /History/Daily/1/Pv/1/Yield, type float
Maximum charge power yesterday tracker 2 (W), dbus path: /History/Daily/1/Pv/2/MaxPower, type float
Yield yesterday for tracker 2 (kWh), dbus path: /History/Daily/1/Pv/2/Yield, type float
Maximum charge power yesterday tracker 3 (W), dbus path: /History/Daily/1/Pv/3/MaxPower, type float
Yield yesterday for tracker 3 (kWh), dbus path: /History/Daily/1/Pv/3/Yield, type float
Yield yesterday (kWh), dbus path: /History/Daily/1/Yield, type float
Load state, dbus path: /Load/State, type enum

  • 0 - Off
  • 1 - On

Charger on/off, dbus path: /Mode, type enum

  • 1 - On
  • 4 - Off

MPP operation mode, dbus path: /MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage or current limited
  • 2 - MPPT Tracker active
  • 255 - Not available

MPP operation mode tracker 1, dbus path: /Pv/0/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

Tracker 1 power, dbus path: /Pv/0/P, type float
Tracker 1 voltage, dbus path: /Pv/0/V, type float
MPP operation mode tracker 2, dbus path: /Pv/1/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

Tracker 2 power, dbus path: /Pv/1/P, type float
Tracker 2 voltage, dbus path: /Pv/1/V, type float
MPP operation mode tracker 3, dbus path: /Pv/2/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

Tracker 3 power, dbus path: /Pv/2/P, type float
Tracker 3 voltage, dbus path: /Pv/2/V, type float
MPP operation mode tracker 4, dbus path: /Pv/3/MppOperationMode, type enum

  • 0 - Off
  • 1 - Voltage/current limited
  • 2 - MPPT active
  • 255 - Not available

Tracker 4 power, dbus path: /Pv/3/P, type float
Tracker 4 voltage, dbus path: /Pv/3/V, type float
PV voltage, dbus path: /Pv/V, type float
Relay on the charger, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Charge state, dbus path: /State, type enum

  • 0 - Off
  • 2 - Fault
  • 3 - Bulk
  • 4 - Absorption
  • 5 - Float
  • 6 - Storage
  • 7 - Equalize
  • 245 - Off
  • 247 - Equalize
  • 252 - External Control

PV Power (W), dbus path: /Yield/Power, type float
Yield since last update (kWh), dbus path: /Yield/System, type string
Yield since reset (kWh), dbus path: /Yield/User, type string

System

This input node takes is for retrieving information from the com.victronenergy.system dbus path.

AC-Input, dbus path: /Ac/ActiveIn/Source, type enum

  • 0 - Not available
  • 1 - Grid
  • 2 - Generator
  • 3 - Shore
  • 240 - Inverting

AC Consumption L1 (W), dbus path: /Ac/Consumption/L1/Power, type float
AC Consumption L2 (W), dbus path: /Ac/Consumption/L2/Power, type float
AC Consumption L3 (W), dbus path: /Ac/Consumption/L3/Power, type float
Power between meter and inverter/charger, L1 (W), dbus path: /Ac/ConsumptionOnInput/L1/Power, type float
Power between meter and inverter/charger, L2 (W), dbus path: /Ac/ConsumptionOnInput/L2/Power, type float
Power between meter and inverter/charger, L3 (W), dbus path: /Ac/ConsumptionOnInput/L3/Power, type float
Power on output of inverter/charger, L1 (W), dbus path: /Ac/ConsumptionOnOutput/L1/Power, type float
Power on output of inverter/charger, L2 (W), dbus path: /Ac/ConsumptionOnOutput/L2/Power, type float
Power on output of inverter/charger, L3 (W), dbus path: /Ac/ConsumptionOnOutput/L3/Power, type float
Genset Device Type, dbus path: /Ac/Genset/DeviceType, type float
Genset L1 (W), dbus path: /Ac/Genset/L1/Power, type float
Genset L2 (W), dbus path: /Ac/Genset/L2/Power, type float
Genset L3 (W), dbus path: /Ac/Genset/L3/Power, type float
Genset Number Of Phases, dbus path: /Ac/Genset/NumberOfPhases, type integer
Grid Device Type, dbus path: /Ac/Grid/DeviceType, type float
Grid L1 (W), dbus path: /Ac/Grid/L1/Power, type float
Grid L2 (W), dbus path: /Ac/Grid/L2/Power, type float
Grid L3 (W), dbus path: /Ac/Grid/L3/Power, type float
Grid Number Of Phases, dbus path: /Ac/Grid/NumberOfPhases, type integer
PV Power AC-tied on Generator L1, dbus path: /Ac/PvOnGenset/L1/Power, type float
PV Power AC-tied on Generator L2, dbus path: /Ac/PvOnGenset/L2/Power, type float
PV Power AC-tied on Generator L3, dbus path: /Ac/PvOnGenset/L3/Power, type float
PV Power AC-tied on Generator Number Of Phases, dbus path: /Ac/PvOnGenset/NumberOfPhases, type integer
PV - AC-coupled on input L1 (W), dbus path: /Ac/PvOnGrid/L1/Power, type float
PV - AC-coupled on input L2 (W), dbus path: /Ac/PvOnGrid/L2/Power, type float
PV - AC-coupled on input L3 (W), dbus path: /Ac/PvOnGrid/L3/Power, type float
PV - AC-coupled on input Number Of Phases, dbus path: /Ac/PvOnGrid/NumberOfPhases, type integer
PV - AC-coupled on output L1 (W), dbus path: /Ac/PvOnOutput/L1/Power, type float
PV - AC-coupled on output L2 (W), dbus path: /Ac/PvOnOutput/L2/Power, type float
PV - AC-coupled on output L3 (W), dbus path: /Ac/PvOnOutput/L3/Power, type float
PV - AC-coupled on output Number Of Phases, dbus path: /Ac/PvOnOutput/NumberOfPhases, type integer
Buzzer State, dbus path: /Buzzer/State, type float
ESS active SOC limit (%), dbus path: /Control/ActiveSocLimit, type integer
Battery Consumed Amphours (Ah), dbus path: /Dc/Battery/ConsumedAmphours, type float
Battery current (A), dbus path: /Dc/Battery/Current, type float
Battery Power (W), dbus path: /Dc/Battery/Power, type float
Battery State of Charge (%), dbus path: /Dc/Battery/Soc, type float
Battery state, dbus path: /Dc/Battery/State, type enum

  • 0 - idle
  • 1 - charging
  • 2 - discharging

Battery temperature (°C), dbus path: /Dc/Battery/Temperature, type float
Battery Time to Go (s), dbus path: /Dc/Battery/TimeToGo, type float
Battery voltage (V), dbus path: /Dc/Battery/Voltage, type float
AC-Chargers - power (W), dbus path: /Dc/Charger/Power, type integer
Inverter/Charger current, dbus path: /Dc/InverterCharger/Current, type float
Inverter/Charger power, dbus path: /Dc/InverterCharger/Power, type float
MPPTs - current (A), dbus path: /Dc/Pv/Current, type float
MPPTs - power (W), dbus path: /Dc/Pv/Power, type float
DC System (W), dbus path: /Dc/System/Power, type float
VE.Bus charge current (A), dbus path: /Dc/Vebus/Current, type float
VE.Bus charge power (W), dbus path: /Dc/Vebus/Power, type float
Serial (System), dbus path: /Serial, type string
System type, dbus path: /SystemType, type string
Time off (s), dbus path: /Timers/TimeOff, type float
Time generator (s), dbus path: /Timers/TimeOnGenerator, type float
Time grid (s), dbus path: /Timers/TimeOnGrid, type float
Time inverting (s), dbus path: /Timers/TimeOnInverter, type float

Tank Sensor

The input-tank node is for retrieving tank level sensor information.Also see the manual for more information.

Tank capacity (m3), dbus path: /Capacity, type float
Fluid type, dbus path: /FluidType, type enum

  • 0 - Fuel
  • 1 - Fresh water
  • 2 - Waste water
  • 3 - Live well
  • 4 - Oil
  • 5 - Black water (sewage)
  • 6 - Gasoline
  • 7 - Diesel
  • 8 - Liquid Petroleum Gas (LPG)
  • 9 - Liquid Natural Gas (LNG)
  • 10 - Hydraulic oil
  • 11 - Raw water

Tank level (%), dbus path: /Level, type float
Product ID, dbus path: /ProductId, type float
Fluid remaining (m3), dbus path: /Remaining, type float
Tank sensor status, dbus path: /Status, type enum

  • 0 - Ok
  • 1 - Open circuit
  • 2 - Short circuited
  • 3 - Reverse polarity
  • 4 - Unknown

Temperature Sensor

input-temperature node reads the temperate information from the dbus. This means that source of the temperature sensor can obtain its information from different sources (e.g. directly connected probe or Bluetooth connected Ruuvi tag).See the manual for information on connecting a temperature sensor.Tank sensors also expose temperature, so they can appear under the dropdown too.

Acceleration X (g), dbus path: /AccelX, type float
Acceleration Y (g), dbus path: /AccelY, type float
Acceleration Z (g), dbus path: /AccelZ, type float
Sensor battery voltage (V), dbus path: /BatteryVoltage, type float
Humidity (%), dbus path: /Humidity, type float
Temperature offset, dbus path: /Offset, type float
Pressure (kPa), dbus path: /Pressure, type float
Product ID, dbus path: /ProductId, type float
Temperature scale factor, dbus path: /Scale, type float
Sensor status, dbus path: /Status, type enum

  • 0 - Ok
  • 1 - Open circuit
  • 2 - Short circuited
  • 3 - Reverse polarity
  • 4 - Unknown

Temperature (°C), dbus path: /Temperature, type float
Sensor type, dbus path: /TemperatureType, type enum

  • 0 - Battery
  • 1 - Fridge
  • 2 - Generic

Sensor battery voltage (V), dbus path: /BatteryVoltage, type float
Temperature (°C), dbus path: /Temperature, type float

VE.Bus System

Information from VE.Bus connected devices can be obtained with this node.

Active input, dbus path: /Ac/ActiveIn/ActiveInput, type enum

  • 0 - AC Input 1
  • 1 - AC Input 2
  • 240 - Disconnected

Active input current limit (A), dbus path: /Ac/ActiveIn/CurrentLimit, type float
Input frequency phase 1 (Hz), dbus path: /Ac/ActiveIn/L1/F, type float
Input current phase 1 (A), dbus path: /Ac/ActiveIn/L1/I, type float
Input power phase 1 (W), dbus path: /Ac/ActiveIn/L1/P, type float
Input voltage phase 1 (VAC), dbus path: /Ac/ActiveIn/L1/V, type float
Input frequency phase 2 (Hz), dbus path: /Ac/ActiveIn/L2/F, type float
Input current phase 2 (A), dbus path: /Ac/ActiveIn/L2/I, type float
Input power phase 2 (W), dbus path: /Ac/ActiveIn/L2/P, type float
Input voltage phase 2 (VAC), dbus path: /Ac/ActiveIn/L2/V, type float
Input frequency phase 3 (Hz), dbus path: /Ac/ActiveIn/L3/F, type float
Input current phase 3 (A), dbus path: /Ac/ActiveIn/L3/I, type float
Input power phase 3 (W), dbus path: /Ac/ActiveIn/L3/P, type float
Input voltage phase 3 (VAC), dbus path: /Ac/ActiveIn/L3/V, type float
Select Remote Generator, dbus path: /Ac/Control/RemoteGeneratorSelected, type enum

  • 0 - Generator not selected
  • 1 - Generator selected

Input 1 current limit (A), dbus path: /Ac/In/1/CurrentLimit, type float
Input 1 current limit is adjustable, dbus path: /Ac/In/1/CurrentLimitIsAdjustable, type enum

  • 0 - No
  • 1 - Yes

Input 2 current limit (A), dbus path: /Ac/In/2/CurrentLimit, type float
Input 2 current limit is adjustable, dbus path: /Ac/In/2/CurrentLimitIsAdjustable, type enum

  • 0 - No
  • 1 - Yes

Phase count, dbus path: /Ac/NumberOfPhases, type float
Output frequency phase 1 (Hz), dbus path: /Ac/Out/L1/F, type float
Output current phase 1 (A), dbus path: /Ac/Out/L1/I, type float
Output power phase 1 (W), dbus path: /Ac/Out/L1/P, type float
Output voltage phase 1 (VAC), dbus path: /Ac/Out/L1/V, type float
Output current phase 2 (A), dbus path: /Ac/Out/L2/I, type float
Output power phase 2 (W), dbus path: /Ac/Out/L2/P, type float
Output voltage phase 2 (VAC), dbus path: /Ac/Out/L2/V, type float
Output current phase 3 (A), dbus path: /Ac/Out/L3/I, type float
Output power phase 3 (W), dbus path: /Ac/Out/L3/P, type float
Output voltage phase 3 (VAC), dbus path: /Ac/Out/L3/V, type float
AC input 1 ignored, dbus path: /Ac/State/IgnoreAcIn1, type enum

  • 0 - AC input not ignored
  • 1 - AC input ignored

AC input 2 ignored, dbus path: /Ac/State/IgnoreAcIn2, type enum

  • 0 - AC input not ignored
  • 1 - AC input ignored

Remote generator selected, dbus path: /Ac/State/RemoteGeneratorSelected, type enum

  • 0 - Generator not selected
  • 1 - Generator selected

Low cell voltage imminent, dbus path: /Alarms/BmsPreAlarm, type enum

  • 0 - OK
  • 1 - Warning

Grid lost alarm, dbus path: /Alarms/GridLost, type enum

  • 0 - Ok
  • 2 - Alarm

Temperature, dbus path: /Alarms/HighTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Temperature alarm L1, dbus path: /Alarms/L1/HighTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low battery alarm L1, dbus path: /Alarms/L1/LowBattery, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Overload alarm L1, dbus path: /Alarms/L1/Overload, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Ripple alarm L1, dbus path: /Alarms/L1/Ripple, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Temperature alarm L2, dbus path: /Alarms/L2/HighTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low battery alarm L2, dbus path: /Alarms/L2/LowBattery, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Overload alarm L2, dbus path: /Alarms/L2/Overload, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Ripple alarm L2, dbus path: /Alarms/L2/Ripple, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Temperature alarm L3, dbus path: /Alarms/L3/HighTemperature, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low battery alarm L3, dbus path: /Alarms/L3/LowBattery, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Overload alarm L3, dbus path: /Alarms/L3/Overload, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Ripple alarm L3, dbus path: /Alarms/L3/Ripple, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Low battery, dbus path: /Alarms/LowBattery, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Overload, dbus path: /Alarms/Overload, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Phase Rotation, dbus path: /Alarms/PhaseRotation, type enum

  • 0 - Ok
  • 1 - Warning

Temperature sensor alarm, dbus path: /Alarms/TemperatureSensor, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

Voltage sensor alarm, dbus path: /Alarms/VoltageSensor, type enum

  • 0 - Ok
  • 1 - Warning
  • 2 - Alarm

BMS allows battery to be charged, dbus path: /Bms/AllowToCharge, type enum

  • 0 - No
  • 1 - Yes

BMS allows battery to be discharged, dbus path: /Bms/AllowToDischarge, type enum

  • 0 - No
  • 1 - Yes

VE.Bus BMS is expected, dbus path: /Bms/BmsExpected, type enum

  • 0 - No
  • 1 - Yes

VE.Bus BMS error, dbus path: /Bms/Error, type enum

  • 0 - No
  • 1 - Yes

Low cell voltage imminent, dbus path: /Bms/PreAlarm, type enum

  • 0 - OK
  • 1 - Pre-Alarm

Battery current (A), dbus path: /Dc/0/Current, type float
Prefer Renewable Energy, dbus path: /Dc/0/PreferRenewableEnergy, type enum

  • 0 - Renewable energy not preferred
  • 1 - Renewable energy preferred

Battery temperature (°C), dbus path: /Dc/0/Temperature, type float
Battery voltage (V), dbus path: /Dc/0/Voltage, type float
Configured boost factor for VE.Bus unit 1, dbus path: /Devices/0/Settings/AssistCurrentBoostFactor, type float
Configured output voltage for VE.Bus unit 1 (V AC), dbus path: /Devices/0/Settings/InverterOutputVoltage, type float
PowerAssist enabled unit 1, dbus path: /Devices/0/Settings/PowerAssistEnabled, type enum

  • 0 - Disabled
  • 1 - Enabled

Energy ACIn1 to AcOut (kWh), dbus path: /Energy/AcIn1ToAcOut, type float
Energy AcIn1 to Inverter (kWh), dbus path: /Energy/AcIn1ToInverter, type float
Energy ACIn2 to AcOut (kWh), dbus path: /Energy/AcIn2ToAcOut, type float
Energy ACIn2 to Inverter (kWh), dbus path: /Energy/AcIn2ToInverter, type float
Energy AcOut to AcIn1 (kWh), dbus path: /Energy/AcOutToAcIn1, type float
Energy AcOut to AcIn2 (kWh), dbus path: /Energy/AcOutToAcIn2, type float
Energy Inverter to AcIn1 (kWh), dbus path: /Energy/InverterToAcIn1, type float
Energy Inverter to AcIn2 (kWh), dbus path: /Energy/InverterToAcIn2, type float
Inverter To AcOut (kWh), dbus path: /Energy/InverterToAcOut, type float
AcOut to Inverter (kWh), dbus path: /Energy/OutToInverter, type float
ESS disable charge flag phase, dbus path: /Hub4/DisableCharge, type enum

  • 0 - Charge allowed
  • 1 - Charge disabled

Solar offset voltage, dbus path: /Hub4/FixSolarOffsetTo100mV, type enum

  • 0 - OvervoltageFeedIn uses 1V offset
  • 1 - OvervoltageFeedIn uses 0.1V offset

Sustain active, dbus path: /Hub4/Sustain, type enum

  • 0 - Sustain inactive
  • 1 - Sustain active

AcPowerSetpoint acts as feed-in limit, dbus path: /Hub4/TargetPowerIsMaxFeedIn, type enum

  • 0 - AcPowerSetpoint interpreted normally
  • 1 - AcPowerSetpoint is OvervoltageFeedIn limit

Switch Position, dbus path: /Mode, type enum

  • 1 - Charger Only
  • 2 - Inverter Only
  • 3 - On
  • 4 - Off

Mode is adjustable, dbus path: /ModeIsAdjustable, type enum

  • 0 - No
  • 1 - Yes

Configured output voltage (V AC), dbus path: /Settings/InverterOutputVoltage, type float
PowerAssist enabled, dbus path: /Settings/PowerAssistEnabled, type enum

  • 0 - Disabled
  • 1 - Enabled

UPS function enabled, dbus path: /Settings/UpsFunction, type enum

  • 0 - Disabled
  • 1 - Enabled

VE.Bus state of charge (%), dbus path: /Soc, type float
VE.Bus state, dbus path: /State, type enum

  • 0 - Off
  • 1 - Low Power
  • 2 - Fault
  • 3 - Bulk
  • 4 - Absorption
  • 5 - Float
  • 6 - Storage
  • 7 - Equalize
  • 8 - Passthru
  • 9 - Inverting
  • 10 - Power assist
  • 11 - Power supply
  • 252 - External control

Charge state, dbus path: /VebusChargeState, type enum

  • 0 - Initialising
  • 1 - Bulk
  • 2 - Absorption
  • 3 - Float
  • 4 - Storage
  • 5 - Absorb repeat
  • 6 - Forced absorb
  • 7 - Equalise
  • 8 - Bulk stopped
  • 9 - Unknown

VE.Bus Error, dbus path: /VebusError, type enum

  • 0 - No error
  • 1 - VE.Bus Error 1: Device is switched off because one of the other phases in the system has switched off
  • 2 - VE.Bus Error 2: New and old types MK2 are mixed in the system
  • 3 - VE.Bus Error 3: Not all, or more than, the expected devices were found in the system
  • 4 - VE.Bus Error 4: No other device whatsoever detected
  • 5 - VE.Bus Error 5: Overvoltage on AC-out
  • 6 - VE.Bus Error 6: Error in DDC Program
  • 7 - VE.Bus Error 7: BMS connected, which requires an Assistant, but no assistant found
  • 8 - VE.Bus Error 8: Ground relay test failed
  • 9 - VE.Bus Error 9
  • 10 - VE.Bus Error 10: System time synchronisation problem occurred
  • 11 - VE.Bus Error 11: Relay test fault
  • 12 - VE.Bus Error 12
  • 13 - VE.Bus Error 13
  • 14 - VE.Bus Error 14: Device cannot transmit data
  • 15 - VE.Bus Error 15
  • 16 - VE.Bus Error 16: Awaiting configuration or dongle missing
  • 17 - VE.Bus Error 17: Phase master missing
  • 18 - VE.Bus Error 18: AC Overvoltage on the output of a slave has occurred while already switched off
  • 19 - VE.Bus Error 19
  • 20 - VE.Bus Error 20
  • 21 - VE.Bus Error 21
  • 22 - VE.Bus Error 22: This device cannot function as slave
  • 23 - VE.Bus Error 23
  • 24 - VE.Bus Error 24: Switch-over system protection initiated
  • 25 - VE.Bus Error 25: Firmware incompatibility. The firmware of one of the connected device is not sufficiently up to date to operate in conjunction with this device
  • 26 - VE.Bus Error 26: Internal error
  • 27 - VE.Bus Error 27
  • 28 - VE.Bus Error 28
  • 29 - VE.Bus Error 29
  • 30 - VE.Bus Error 30
  • 31 - VE.Bus Error 31
  • 32 - VE.Bus Error 32

Output nodes

Output nodes have the same options available as input nodes, but the selectable measurement only lists writable services. Additionally, the user can set an initial value to the service, which is sent whenever the flow is deployed.

  • Device select - lists all available devices
  • Measurement select - lists all available device-specific measurements
  • Initial value input field - lists all available device-specific measurements
  • Node label input field - sets a custom label for the node

All output nodes should have the control value set in its incoming messages msg.payload property.

output nodes

AC Charger Control

This node is for controlling the AC charger.

AC Current limit (A), dbus path: /Ac/In/CurrentLimit, type float
Charger on/off, dbus path: /Mode, type enum

  • 1 - On
  • 4 - Off

Relay on the charger, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

AC System Control

This node is for controlling the Multi-RS and other future inverter/chargers.

ESS setpoint (W), dbus path: /Ess/AcPowerSetpoint, type float
Disable Feed-in (into grid), dbus path: /Ess/DisableFeedIn, type enum

  • 0 - Feed-in enabled
  • 1 - Feed-in disabled

ESS mode, dbus path: /Settings/Ess/Mode, type enum

  • 1 - ESS with Phase Compensation
  • 2 - ESS without phase compensation
  • 3 - Disabled/External Control

Battery Monitor Control

Battery monitor output node, which can be used for controlling a Lynx Smart BMS.

Mode, dbus path: /Mode, type enum

  • 3 - On
  • 252 - Standby

Charger Control

This node allows for controlling a connected charger.

AC Current limit (A AC), dbus path: /Ac/In/CurrentLimit, type float
Charger on/off, dbus path: /Mode, type enum

  • 0 - Off
  • 1 - On

DC-DC Control

This node allows for controlling an Orion XS.

/Mode, dbus path: /Mode, type enum

  • 1 - On
  • 4 - Off

Dynamic ESS Control

Dynamic ESS output node.

Battery capacity (kWh), dbus path: /Settings/DynamicEss/BatteryCapacity, type float
Full battery charge duration (hour), dbus path: /Settings/DynamicEss/FullChargeDuration, type float
Full battery charge interval (day), dbus path: /Settings/DynamicEss/FullChargeInterval, type float
Dynamic ESS mode, dbus path: /Settings/DynamicEss/Mode, type enum

  • 0 - Off
  • 1 - Auto
  • 4 - Node-RED

Allow grid feed-in during schedule 0, dbus path: /Settings/DynamicEss/Schedule/0/AllowGridFeedIn, type enum

  • 0 - Not allowed
  • 1 - Allowed

Duration for schedule 0 (Seconds), dbus path: /Settings/DynamicEss/Schedule/0/Duration, type float
Active restrictions for schedule 0, dbus path: /Settings/DynamicEss/Schedule/0/Restrictions, type enum

  • 0 - No restrictions between battery and the grid
  • 1 - Grid to battery energy flow is restricted
  • 2 - Battery to grid energy flow is restricted
  • 3 - No energy flow between battery and grid

Target SOC for schedule 0 (%), dbus path: /Settings/DynamicEss/Schedule/0/Soc, type float
Used strategy for schedule 0, dbus path: /Settings/DynamicEss/Schedule/0/Strategy, type enum

  • 0 - Target SOC
  • 1 - Self-consumption

Allow grid feed-in during schedule 1, dbus path: /Settings/DynamicEss/Schedule/1/AllowGridFeedIn, type enum

  • 0 - Not allowed
  • 1 - Allowed

Duration for schedule 1 (Seconds), dbus path: /Settings/DynamicEss/Schedule/1/Duration, type float
Active restrictions for schedule 1, dbus path: /Settings/DynamicEss/Schedule/1/Restrictions, type enum

  • 0 - No restrictions between battery and the grid
  • 1 - Grid to battery energy flow is restricted
  • 2 - Battery to grid energy flow is restricted
  • 3 - No energy flow between battery and grid

Target SOC for schedule 1 (%), dbus path: /Settings/DynamicEss/Schedule/1/Soc, type float
Used strategy for schedule 1, dbus path: /Settings/DynamicEss/Schedule/1/Strategy, type enum

  • 0 - Target SOC
  • 1 - Self-consumption

Allow grid feed-in during schedule 2, dbus path: /Settings/DynamicEss/Schedule/2/AllowGridFeedIn, type enum

  • 0 - Not allowed
  • 1 - Allowed

Duration for schedule 2 (Seconds), dbus path: /Settings/DynamicEss/Schedule/2/Duration, type float
Active restrictions for schedule 2, dbus path: /Settings/DynamicEss/Schedule/2/Restrictions, type enum

  • 0 - No restrictions between battery and the grid
  • 1 - Grid to battery energy flow is restricted
  • 2 - Battery to grid energy flow is restricted
  • 3 - No energy flow between battery and grid

Target SOC for schedule 2 (%), dbus path: /Settings/DynamicEss/Schedule/2/Soc, type float
Used strategy for schedule 2, dbus path: /Settings/DynamicEss/Schedule/2/Strategy, type enum

  • 0 - Target SOC
  • 1 - Self-consumption

Allow grid feed-in during schedule 3, dbus path: /Settings/DynamicEss/Schedule/3/AllowGridFeedIn, type enum

  • 0 - Not allowed
  • 1 - Allowed

Duration for schedule 3 (Seconds), dbus path: /Settings/DynamicEss/Schedule/3/Duration, type float
Active restrictions for schedule 3, dbus path: /Settings/DynamicEss/Schedule/3/Restrictions, type enum

  • 0 - No restrictions between battery and the grid
  • 1 - Grid to battery energy flow is restricted
  • 2 - Battery to grid energy flow is restricted
  • 3 - No energy flow between battery and grid

Target SOC for schedule 3 (%), dbus path: /Settings/DynamicEss/Schedule/3/Soc, type float
Used strategy for schedule 3, dbus path: /Settings/DynamicEss/Schedule/3/Strategy, type enum

  • 0 - Target SOC
  • 1 - Self-consumption

ESS Control

This node allows for controlling the Energy Storage System (ESS).

Disable charge, dbus path: /Hub4/DisableCharge, type enum

  • 0 - No
  • 1 - Yes

Disable feed-in, dbus path: /Hub4/DisableFeedIn, type enum

  • 0 - No
  • 1 - Yes

Feed in overvoltage, dbus path: /Hub4/DoNotFeedInOvervoltage, type enum

  • 0 - Yes
  • 1 - No

AC Power L1 setpoint (W), dbus path: /Hub4/L1/AcPowerSetpoint, type integer
Maximum overvoltage feed-in power L1 (W), dbus path: /Hub4/L1/MaxFeedInPower, type integer
AC Power L2 setpoint (W), dbus path: /Hub4/L2/AcPowerSetpoint, type integer
Maximum overvoltage feed-in power L2 (W), dbus path: /Hub4/L2/MaxFeedInPower, type integer
AC Power L3 setpoint (W), dbus path: /Hub4/L3/AcPowerSetpoint, type integer
Maximum overvoltage feed-in power L3 (W), dbus path: /Hub4/L3/MaxFeedInPower, type integer
Grid set-point (W), dbus path: /Settings/CGwacs/AcPowerSetPoint, type integer
Minimum Discharge SOC (%), dbus path: /Settings/CGwacs/BatteryLife/MinimumSocLimit, type integer
Schedule 1: Self-consumption above limit, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/0/AllowDischarge, type enum

  • 0 - Yes
  • 1 - No

Schedule 1: Day, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/0/Day, type enum

  • 0 - Sunday
  • 1 - Monday
  • 2 - Tuesday
  • 3 - Wednesday
  • 4 - Thursday
  • 5 - Friday
  • 6 - Saturday
  • 7 - Every day
  • 8 - Weekdays
  • 9 - Weekends

Writing a negative value to the path will de-activate the schedule.

Schedule 1: Duration (seconds), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/0/Duration, type integer
Schedule 1: State of charge (%), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/0/Soc, type integer
Schedule 1: Start (seconds after midnight), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/0/Start, type integer
Schedule 2: Self-consumption above limit, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/1/AllowDischarge, type enum
  • 0 - Yes
  • 1 - No

Schedule 2: Day, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/1/Day, type enum

  • 0 - Sunday
  • 1 - Monday
  • 2 - Tuesday
  • 3 - Wednesday
  • 4 - Thursday
  • 5 - Friday
  • 6 - Saturday
  • 7 - Every day
  • 8 - Weekdays
  • 9 - Weekends

Writing a negative value to the path will de-activate the schedule.

Schedule 2: Duration (seconds), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/1/Duration, type integer
Schedule 2: State of charge (%), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/1/Soc, type integer
Schedule 2: Start (seconds after midnight), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/1/Start, type integer
Schedule 3: Self-consumption above limit, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/2/AllowDischarge, type enum
  • 0 - Yes
  • 1 - No

Schedule 3: Day, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/2/Day, type enum

  • 0 - Sunday
  • 1 - Monday
  • 2 - Tuesday
  • 3 - Wednesday
  • 4 - Thursday
  • 5 - Friday
  • 6 - Saturday
  • 7 - Every day
  • 8 - Weekdays
  • 9 - Weekends

Writing a negative value to the path will de-activate the schedule.

Schedule 3: Duration (seconds), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/2/Duration, type integer
Schedule 3: State of charge (%), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/2/Soc, type integer
Schedule 3: Start (seconds after midnight), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/2/Start, type integer
Schedule 4: Self-consumption above limit, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/3/AllowDischarge, type enum
  • 0 - Yes
  • 1 - No

Schedule 4: Day, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/3/Day, type enum

  • 0 - Sunday
  • 1 - Monday
  • 2 - Tuesday
  • 3 - Wednesday
  • 4 - Thursday
  • 5 - Friday
  • 6 - Saturday
  • 7 - Every day
  • 8 - Weekdays
  • 9 - Weekends

Writing a negative value to the path will de-activate the schedule.

Schedule 4: Duration (seconds), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/3/Duration, type integer
Schedule 4: State of charge (%), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/3/Soc, type integer
Schedule 4: Start (seconds after midnight), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/3/Start, type integer
Schedule 5: Self-consumption above limit, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/4/AllowDischarge, type enum
  • 0 - Yes
  • 1 - No

Schedule 5: Day, dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/4/Day, type enum

  • 0 - Sunday
  • 1 - Monday
  • 2 - Tuesday
  • 3 - Wednesday
  • 4 - Thursday
  • 5 - Friday
  • 6 - Saturday
  • 7 - Every day
  • 8 - Weekdays
  • 9 - Weekends

Writing a negative value to the path will de-activate the schedule.

Schedule 5: Duration (seconds), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/4/Duration, type integer
Schedule 5: State of charge (%), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/4/Soc, type integer
Schedule 5: Start (seconds after midnight), dbus path: /Settings/CGwacs/BatteryLife/Schedule/Charge/4/Start, type integer
ESS state, dbus path: /Settings/CGwacs/BatteryLife/State, type enum
  • 1 - BatteryLife enabled (GUI controlled)
  • 2 - Optimized Mode /w BatteryLife: self consumption
  • 3 - Optimized Mode /w BatteryLife: self consumption, SoC exceeds 85%
  • 4 - Optimized Mode /w BatteryLife: self consumption, SoC at 100%
  • 5 - Optimized Mode /w BatteryLife: SoC below dynamic SoC limit
  • 6 - Optimized Mode /w BatteryLife: SoC has been below SoC limit for more than 24 hours. Charging the battery (5A)
  • 7 - Optimized Mode /w BatteryLife: Inverter/Charger is in sustain mode
  • 8 - Optimized Mode /w BatteryLife: recharging, SoC dropped by 5% or more below the minimum SoC
  • 9 - 'Keep batteries charged' mode is enabled
  • 10 - Optimized mode w/o BatteryLife: self consumption, SoC at or above minimum SoC
  • 11 - Optimized mode w/o BatteryLife: self consumption, SoC is below minimum SoC
  • 12 - Optimized mode w/o BatteryLife: recharging, SoC dropped by 5% or more below minimum SoC

ESS mode, dbus path: /Settings/CGwacs/Hub4Mode, type enum

  • 1 - Optimized mode or 'keep batteries charged' and phase compensation enabled
  • 2 - Optimized mode or 'keep batteries charged' and phase compensation disabled
  • 3 - External control

Max charge power (W), dbus path: /Settings/CGwacs/MaxChargePower, type integer

Not used with DVCC.

Max inverter power (W), dbus path: /Settings/CGwacs/MaxDischargePower, type integer
Maximum System Grid Feed In (W), dbus path: /Settings/CGwacs/MaxFeedInPower, type integer
  • -1: No limit
  • >=0: limited system feed-in

Applies to DC-coupled and AC-coupled feed-in.

Feed excess DC-coupled PV into grid, dbus path: /Settings/CGwacs/OvervoltageFeedIn, type enum
  • 0 - Don’t feed excess DC-tied PV into grid
  • 1 - Feed excess DC-tied PV into the grid

Don’t feed excess AC-coupled PV into grid, dbus path: /Settings/CGwacs/PreventFeedback, type enum

  • 0 - Feed excess AC-tied PV into grid
  • 1 - Don’t feed excess AC-tied PV into the grid

Grid metering, dbus path: /Settings/CGwacs/RunWithoutGridMeter, type enum

  • 0 - External meter
  • 1 - Inverter/Charger

Charge current limit (A), dbus path: /Settings/SystemSetup/MaxChargeCurrent, type float

EV Charger Control

With this node the EV charging station can be controlled.Note that you need to refresh the website of the EV charger in order to see the changed settings there.

Display, dbus path: /EnableDisplay, type enum

  • 0 - Locked
  • 1 - Unlocked

Maximum charge current (A), dbus path: /MaxCurrent, type float
Mode, dbus path: /Mode, type enum

  • 0 - Manual
  • 1 - Auto
  • 2 - Schedule

Position, dbus path: /Position, type enum

  • 0 - AC input 1
  • 1 - AC output
  • 2 - AC input 2

Set charge current (manual mode) (A), dbus path: /SetCurrent, type float
Start/stop charging (manual mode), dbus path: /StartStop, type enum

  • 0 - Stop
  • 1 - Start

GX Generator Control

This node can be used for controlling a generator via the relay. In order to use the relay for controlling a generator, make sure to set the relay to Generator via the (remote) console first.

Auto start enabled/disabled, dbus path: /AutoStartEnabled, type enum

  • 0 - Autostart disabled
  • 1 - Autostart enabled

Manual Start, dbus path: /ManualStart, type enum

  • 0 - Stop generator
  • 1 - Start generator

Set it before a manual start to make the generator run for a fixed amount of seconds. Once the generator is started it indicates the seconds left until the generator is stopped, dbus path: /ManualStartTimer, type float
Service countdown reset (1=Reset service counter), dbus path: /ServiceCounterReset, type float
Start generator, dbus path: /Start, type enum

  • 0 - Stop
  • 1 - Start

Start generator, dbus path: /Start, type enum

  • 0 - Stop generator
  • 1 - Start generator

Inverter Control

This node can be used for controlling the inverter.

Mode, dbus path: /Mode, type enum

  • 2 - Inverter on
  • 4 - Off
  • 5 - Low Power/ECO

Multi RS Control

Multi RS output node.

Ac input 1 current limit (A), dbus path: /Ac/In/1/CurrentLimit, type float
Ac input 2 current limit (A), dbus path: /Ac/In/2/CurrentLimit, type float
ESS power setpoint (W), dbus path: /Ess/AcPowerSetpoint, type float
Disable Feed-in, dbus path: /Ess/DisableFeedIn, type enum

  • 0 - Feed-in enabled
  • 1 - Feed-in disabled

Disable charge, dbus path: /Ess/DisableCharge, type enum

  • 0 - Charge enabled
  • 1 - Charge disabled

ESS Minimum SOC Limit (%), dbus path: /Settings/Ess/MinimumSocLimit, type float
Switch position, dbus path: /Mode, type enum

  • 1 - Charger Only
  • 2 - Inverter Only
  • 3 - On
  • 4 - Off

ESS mode, dbus path: /Settings/Ess/Mode, type enum

  • 0 - self-consumption (battery-life)
  • 1 - self-consumption
  • 2 - Keep charged
  • 3 - External control

Pump Control

Node for controlling a relay connected pump. In auto mode, the pump looks at the connected tank sensor levels for starting and stopping the pump.

Auto start enabled, dbus path: /Settings/Pump0/AutoStartEnabled, type enum

  • 0 - Disabled
  • 1 - Enabled

Mode, dbus path: /Settings/Pump0/Mode, type enum

  • 0 - Auto
  • 1 - On
  • 2 - Off

Start value (%), dbus path: /Settings/Pump0/StartValue, type float
Stop value (%), dbus path: /Settings/Pump0/StopValue, type float

PV Inverter Control

This node is for setting information into the PV inverter.

Power limit (W), dbus path: /Ac/PowerLimit, type float

Relay Control

The relays of the Venus device can be controlled with this node. Make sure to set the relay(s) to Manual via the Venus OS GUI first.

Venus relay 1 state, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Venus relay 2 state, dbus path: /Relay/1/State, type enum

  • 0 - Open
  • 1 - Closed

Venus relay 3 state, dbus path: /Relay/2/State, type enum

  • 0 - Open
  • 1 - Closed

Venus relay 4 state, dbus path: /Relay/3/State, type enum

  • 0 - Open
  • 1 - Closed

Relay status, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Relay on the charger, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Relay state, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Relay on the Multi RS, dbus path: /Relay/0/State, type enum

  • 0 - Open
  • 1 - Closed

Settings Control

With this node several settings can be adjusted. Currently the focus is mainly on the Carlo Gavazzi Wired AC Sensors (cgwacs).

AC export current limit (A), dbus path: /Settings/CGwacs/AcExportLimit, type float
AC import current limit (A), dbus path: /Settings/CGwacs/AcImportLimit, type float
Mode for peakshaving, dbus path: /Settings/CGwacs/AlwaysPeakShave, type enum

  • 0 - Above minimum SOC only
  • 1 - Always

ESS Minimum SoC (unless grid fails) (%), dbus path: /Settings/CGwacs/BatteryLife/MinimumSocLimit, type float
ESS BatteryLife state, dbus path: /Settings/CGwacs/BatteryLife/State, type enum

  • 0 - Unused, BL disabled
  • 1 - Restarting
  • 2 - Self-consumption
  • 3 - Self-consumption
  • 4 - Self-consumption
  • 5 - Discharge disabled
  • 6 - Force charge
  • 7 - Sustain
  • 8 - Low Soc Recharge
  • 9 - Keep batteries charged
  • 10 - BL Disabled
  • 11 - BL Disabled (Low SoC)
  • 12 - BL Disabled (Low SOC recharge)

Auto start enabled, dbus path: /Settings/Pump0/AutoStartEnabled, type enum

  • 0 - Disabled
  • 1 - Enabled

Mode, dbus path: /Settings/Pump0/Mode, type enum

  • 0 - Auto
  • 1 - On
  • 2 - Off

Start value (%), dbus path: /Settings/Pump0/StartValue, type float
Stop value (%), dbus path: /Settings/Pump0/StopValue, type float
DVCC system max charge current (A DC), dbus path: /Settings/SystemSetup/MaxChargeCurrent, type float
ESS Mode, dbus path: /Settings/CGwacs/Hub4Mode, type enum

  • 1 - ESS with Phase Compensation
  • 2 - ESS without phase compensation
  • 3 - Disabled/External Control

ESS max charge current (fractional) (%), dbus path: /Settings/CGwacs/MaxChargePercentage, type float
ESS max discharge current (fractional) (%), dbus path: /Settings/CGwacs/MaxDischargePercentage, type float
ESS max charge power (W), dbus path: /Settings/CGwacs/MaxChargePower, type float
ESS max discharge power (W), dbus path: /Settings/CGwacs/MaxDischargePower, type float
Maximum System Grid Feed In (W), dbus path: /Settings/CGwacs/MaxFeedInPower, type float
Feed excess DC-coupled PV into grid, dbus path: /Settings/CGwacs/OvervoltageFeedIn, type enum

  • 0 - Don’t feed excess DC-tied PV into grid
  • 1 - Feed excess DC-tied PV into the grid

AC-coupled PV - grid feed in excess, dbus path: /Settings/CGwacs/PreventFeedback, type enum

  • 0 - Feed excess AC-tied PV into grid
  • 1 - Don’t feed excess AC-tied PV into the grid

Enable status LEDs, dbus path: /Settings/LEDs/Enable, type enum

  • 0 - Disabled
  • 1 - Enabled

AC input 1 source (for VE.Bus inverter/chargers), dbus path: /Settings/SystemSetup/AcInput1, type enum

  • 0 - Unused
  • 1 - Grid
  • 2 - Genset
  • 3 - Shore

AC input 2 source (for VE.Bus inverter/chargers), dbus path: /Settings/SystemSetup/AcInput2, type enum

  • 0 - Unused
  • 1 - Grid
  • 2 - Genset
  • 3 - Shore

Limit managed battery voltage (V DC), dbus path: /Settings/SystemSetup/MaxChargeVoltage, type float

Solar Charger Control

With this node the solar charger can be switched on and off.

Charger on/off, dbus path: /Mode, type enum

  • 1 - On
  • 4 - Off

VE.Bus System Control

This output node is for writing to VE.Bus connected devices.

Active input current limit (A), dbus path: /Ac/ActiveIn/CurrentLimit, type float
Select Remote Generator, dbus path: /Ac/Control/RemoteGeneratorSelected, type enum

  • 0 - Generator not selected
  • 1 - Generator selected

Input 1 current limit (A), dbus path: /Ac/In/1/CurrentLimit, type float
Input 2 current limit (A), dbus path: /Ac/In/2/CurrentLimit, type float
Prefer Renewable Energy, dbus path: /Dc/0/PreferRenewableEnergy, type enum

  • 0 - Renewable energy not preferred
  • 1 - Renewable energy preferred

Configured boost factor for VE.Bus unit 1, dbus path: /Devices/0/Settings/AssistCurrentBoostFactor, type float
Configured output voltage for VE.Bus unit 1 (V AC), dbus path: /Devices/0/Settings/InverterOutputVoltage, type float
PowerAssist enabled unit 1, dbus path: /Devices/0/Settings/PowerAssistEnabled, type enum

  • 0 - Disabled
  • 1 - Enabled

ESS disable charge flag phase, dbus path: /Hub4/DisableCharge, type enum

  • 0 - Charge allowed
  • 1 - Charge disabled

ESS disable feedback flag phase, dbus path: /Hub4/DisableFeedIn, type enum

  • 0 - Feed in allowed
  • 1 - Feed in disabled

Feed DC overvoltage into grid, dbus path: /Hub4/DoNotFeedInOvervoltage, type enum

  • 0 - Feed in overvoltage
  • 1 - Do not feed in overvoltage

Solar offset voltage, dbus path: /Hub4/FixSolarOffsetTo100mV, type enum

  • 0 - OvervoltageFeedIn uses 1V offset
  • 1 - OvervoltageFeedIn uses 0.1V offset

ESS power setpoint phase 1 (W), dbus path: /Hub4/L1/AcPowerSetpoint, type float
Maximum overvoltage feed-in power L1 (W), dbus path: /Hub4/L1/MaxFeedInPower, type float
ESS power setpoint phase 2 (W), dbus path: /Hub4/L2/AcPowerSetpoint, type float
Maximum overvoltage feed-in power L2 (W), dbus path: /Hub4/L2/MaxFeedInPower, type float
ESS power setpoint phase 3 (W), dbus path: /Hub4/L3/AcPowerSetpoint, type float
Maximum overvoltage feed-in power L3 (W), dbus path: /Hub4/L3/MaxFeedInPower, type float
AcPowerSetpoint acts as feed-in limit, dbus path: /Hub4/TargetPowerIsMaxFeedIn, type enum

  • 0 - AcPowerSetpoint interpreted normally
  • 1 - AcPowerSetpoint is OvervoltageFeedIn limit

Switch Position, dbus path: /Mode, type enum

  • 1 - Charger Only
  • 2 - Inverter Only
  • 3 - On
  • 4 - Off

_

Note that /ModeIsAdjustable needs to be set to 1.

_ Disable PV inverter, dbus path: /PvInverter/Disable, type enum
  • 0 - No
  • 1 - Yes

Redetect VE.Bus system, dbus path: /RedetectSystem, type enum

  • 0 - No action
  • 1 - Redetect system

Power Assist boost factor, dbus path: /Settings/AssistCurrentBoostFactor, type float
Configured output voltage (V AC), dbus path: /Settings/InverterOutputVoltage, type float
PowerAssist enabled, dbus path: /Settings/PowerAssistEnabled, type enum

  • 0 - Disabled
  • 1 - Enabled

UPS function enabled, dbus path: /Settings/UpsFunction, type enum

  • 0 - Disabled
  • 1 - Enabled

VE.Bus state of charge (%), dbus path: /Soc, type float
VE.Bus Reset, dbus path: /SystemReset, type enum

  • 0 - No
  • 1 - Yes

Custom nodes

The custom nodes also have 2 selectable inputs: the (dbus) service and the (dbus) path. This obviously comes with a risk, as not all services and paths are supposed to be written to. So only use the custom output node if you have read the documentation and know what you are doing. Also note that used services and paths might change, so there is no guarantee that a node will remain functional after a Venus firmware update.