Expand Up @@ -459,7 +459,7 @@ ALARM 8011
*Solution:*
Check the [setup instructions](../README.md#installation) to ensure that the robot controller is configured properly.

If the behavior persists, save a copy of the debug-listener script output and the `PANELBOX.LOG` from the robot's teach pendant.
If the behavior persists, save a copy of the output of the [debug-listener script](#debug-log-client) and the `PANELBOX.LOG` from the robot's teach pendant.
Open a new issue on the [Issue tracker](https://github.com/yaskawa-global/motoros2/issues), describe the problem and attach `PANELBOX.LOG` and the debug log to the issue.
Include a verbatim copy of the alarm text as seen on the teach pendant (alarm number and `[subcode]`).

Expand Down Expand Up @@ -582,6 +582,57 @@ The name must not be blank.

After correcting the configuration, the [changes will need to be propagated to the Yaskawa controller](../README.md#updating-the-configuration).

### Alarm: 8011[23 - 54]

*Example:*

```text
ALARM 8011
MotoROS2: Fatal Error
Failed adding ...
[xx]
```

or:

```text
ALARM 8011
MotoROS2: Fatal Error
Failed to init ...
[xx]
```

or:

```text
ALARM 8011
MotoROS2: Fatal Error
Failed creating ...
[xx]
```

Where `[xx]` is a subcode in the ranges `[23 - 54]` or `[56 - 58]`.

*Solution:*
These alarms are often caused by version incompatibilities between ROS 2 (on the client PC), micro-ROS (as part of MotoROS2) and/or the micro-ROS Agent.

Ensure only compatible versions are used.

As an example: the *Humble* version of MotoROS2 should only be used with ROS 2 *Humble* on the client PC and with the *Humble* version of the micro-ROS Agent.
Please also verify the client PC uses a version of ROS 2 that is [supported by MotoROS2](https://github.com/Yaskawa-Global/motoros2#general-requirements).

If the behavior persists, save a copy of the output of the [debug-listener script](#debug-log-client) and the `PANELBOX.LOG` from the robot's teach pendant.
Open a new issue on the [Issue tracker](https://github.com/yaskawa-global/motoros2/issues).
Describe the problem and include the following items:

- `PANELBOX.LOG`
- output from [debug-listener script](#debug-log-client) (complete and unedited)
- version of MotoROS2
ted-miller marked this conversation as resolved.
Show resolved Hide resolved
- version of micro-ROS Agent
- version of ROS 2 on client PC
- copy of `motoros2_config.yaml` copied from the robot controller
- verbatim copy of the alarm text as seen on the teach pendant (alarm number and `[subcode]`).

### Alarm: 8011[55]

*Example:*
Expand Down Expand Up @@ -609,6 +660,48 @@ Refer to [FAQ: Can names of joints be changed?](faq.md#can-names-of-joints-be-ch

After correcting the configuration, the [changes will need to be propagated to the Yaskawa controller](../README.md#updating-the-configuration).

### Alarm: 8011[56 - 58]
gavanderhoorn marked this conversation as resolved.
Show resolved Hide resolved

Please refer to [Alarm: 8011[23 - 54]](#alarm-801123---54).

### Alarm: 8011[59]

*Example:*

```text
ALARM 8011
Host on NIC check x
[59]
```

Where `x` is either `1` or `2`.

*Solution:*
This problem is often caused by the `agent_ip_address` key in the `motoros2_config.yaml` configuration file set to an address that is not reachable by the robot controller.

Options:

1. Modify the `agent_ip_address` key and specify an IP address that is on the robot's subnet.
Now follow the instructions [to propagate the changes to the Yaskawa controller](../README.md#updating-the-configuration).
2. Modify the robot controller's IP so it is on the Agent's subnet.
3. Modify the robot controller's network settings to add a gateway which can reach the Agent's IP address.

Refer to the relevant Yaskawa Motoman documentation for information on how to change the controller's network configuration.

### Alarm: 8011[60 - 62]

*Example:*

```text
ALARM 8011
Must enable ETHERNET function
[60 - 62]
```

*Solution:*
The ETHERNET function must be enabled for one (or both) LAN interface in the robot controller.
Please contact your local Yaskawa representative to request this function.

### Alarm: 8012[xx]

*Example:*
Expand All @@ -622,7 +715,7 @@ ALARM 8012
*Solution:*
Verify there are no other MotoPlus applications (`.out` file) installed on the robot controller.

If the behavior persists, save a copy of the debug-listener script output and the `PANELBOX.LOG` from the robot's teach pendant.
If the behavior persists, save a copy of the output of the [debug-listener script](#debug-log-client) and the `PANELBOX.LOG` from the robot's teach pendant.
Open a new issue on the [Issue tracker](https://github.com/yaskawa-global/motoros2/issues), describe the problem and attach `PANELBOX.LOG` and the debug log to the issue.
Include a verbatim copy of the alarm text as seen on the teach pendant (alarm number and `[subcode]`).

Expand Down Expand Up @@ -848,7 +941,7 @@ If auto-detection is to be used, verify `agent_ip_address` is set to an IP that

After correcting the configuration, the [changes will need to be propagated to the Yaskawa controller](../README.md#updating-the-configuration).

If the behavior persists, save a copy of the debug-listener script output and the `PANELBOX.LOG` from the robot's teach pendant.
If the behavior persists, save a copy of the output of the [debug-listener script](#debug-log-client) and the `PANELBOX.LOG` from the robot's teach pendant.
Open a new issue on the [Issue tracker](https://github.com/yaskawa-global/motoros2/issues), describe the problem and attach `PANELBOX.LOG` and the debug log to the issue.
Include a verbatim copy of the alarm text as seen on the teach pendant (alarm number and `[subcode]`).

Expand All @@ -871,7 +964,7 @@ If the alarm is raised again, make sure `userlan_monitor_port` is set to the cor

If the configuration file has to be updated, the [changes will need to be propagated to the Yaskawa controller](../README.md#updating-the-configuration).

If the behavior persists, save a copy of the debug-listener script output and the `PANELBOX.LOG` from the robot's teach pendant.
If the behavior persists, save a copy of the output of the [debug-listener script](#debug-log-client) and the `PANELBOX.LOG` from the robot's teach pendant.
Open a new issue on the [Issue tracker](https://github.com/yaskawa-global/motoros2/issues), describe the problem and attach `PANELBOX.LOG` and the debug log to the issue.
Include a verbatim copy of the alarm text as seen on the teach pendant (alarm number and `[subcode]`).

Expand Down
12 changes: 6 additions & 6 deletions src/ErrorHandling.h
Original file line number Diff line number Diff line change
Expand Up @@ -91,7 +91,7 @@ typedef enum
SUBCODE_EXECUTOR,
SUBCODE_INCREMENTAL_MOTION,
SUBCODE_ADD_TO_INC_Q,
} TASK_CREATE_FAIL_SUBCODE;
} TASK_CREATE_FAIL_SUBCODE; //8010

typedef enum
{
Expand Down Expand Up @@ -165,14 +165,14 @@ typedef enum
SUBCODE_CONFIGURATION_FAIL_MP_NICDATA1,
SUBCODE_FAIL_MP_NICDATA_INIT1,

} ASSERTION_SUBCODE;
} ASSERTION_SUBCODE; //8011

typedef enum
{
SUBCODE_ALLOCATION_MALLOC,
SUBCODE_ALLOCATION_CALLOC,
SUBCODE_ALLOCATION_REALLOC,
} ALLOCATION_SUBCODE;
} ALLOCATION_SUBCODE; //8012

typedef enum
{
Expand All @@ -193,15 +193,15 @@ typedef enum
SUBCODE_CONFIGURATION_INVALID_USERLAN_MONITOR_PORT,
SUBCODE_CONFIGURATION_USERLAN_MONITOR_AUTO_DETECT_FAILED,
SUBCODE_CONFIGURATION_RUNTIME_USERLAN_LINKUP_ERR,
} CONFIGURATION_SUBCODE;
} CONFIGURATION_SUBCODE; //8013

typedef enum
{
SUBCODE_INFORM_FAIL_TO_OPEN_DRAM,
SUBCODE_INFORM_INVALID_JOB,
SUBCODE_INFORM_FAIL_TO_CREATE_JOB,
SUBCODE_INFORM_FAIL_TO_LOAD_JOB,
} INFORM_SUBCODE;
} INFORM_SUBCODE; //8014

typedef enum
{
Expand All @@ -210,7 +210,7 @@ typedef enum
SUBCODE_DAT_FAIL_PARSE_MGROUP,
SUBCODE_DAT_FAIL_PARSE_SGROUP,
SUBCODE_DAT_FAIL_PARSE_SRANG
} DAT_SUBCODE;
} DAT_SUBCODE; //8015

extern void motoRosAssert(BOOL mustBeTrue, ASSERTION_SUBCODE subCodeIfFalse);
extern void motoRosAssert_withMsg(BOOL mustBeTrue, ASSERTION_SUBCODE subCodeIfFalse, char* msgFmtIfFalse, ...);
Expand Down