[3.7.0] October 27 2024
IMPORTANT! BREAKING CHANGES with 3.6.5
- "ww" and "wwc" has been renamed to "dhw". It is nested JSON object in both the MQTT and API outputs. The old prefix has also been removed from MQTT topics (#1634). This will impact historical data in home automation systems like Home Assistant and IOBroker. To preserve the current value of dhw energy (was previously nrgww) refer to this issue #1938.
- dhw entities from the MM100/SM100 have been moved under a new Device called 'water'.
- The automatically generated temperature sensor ID has replaced dashes (
-
) with underscores (_
) to be compatible with Home Assistant. api/system/info
has it's JSON key names changed to camelCase syntax.
For more details go to www.emsesp.org
Added
- some more entities for dhw with SM100 module
- thermostat second dhw circuit #1634
- remote thermostat emulation for RC100H, RC200 and FB10 #1287, #1602, #1551
- heatpump dhw stop temperatures #1624
- reset history #1695
- heatpump entities
fan
andshutdown
#1690 - mqtt HA-mode 3 for v3.6 compatible HA entities, set on update v3.6->v3.7
- HP input states #1723
- holiday settings for rego 3000 #1735
- Added scripts for OTA (scripts/upload.py and upload_cli.py) #1738
- timeout for remote thermostat emulation #1680, #1774
- CR120 thermostat as own model() #1779
- modules - external linkable module library #1778
- scheduler onChange and Conditions #1806
- make remote control timeout editable #1774
- added extra pump characteristics (mode and pressure for EMS+) by @SLTKA #1802
- allow device name to be customized #1174
- Modbus support by @mheyse #1744
- System Message command #1854
- scheduler can use web get/post for values and commands #1806
- RT800 remote emulation #1867
- RC310 cooling parameters #1857
- command
api/device/entities
#1897 - switchprogmode #1903
- autodetect and download firmware upgrades via the WebUI
- command 'show log' that lists out the current weblog buffer, showing last messages.
- default web log buffer to 25 lines for ESP32s with no PSRAM
- try and determine correct board profile if none is set during boot
- auto Scroll in WebLog UI - reduced delay so incoming logs are faster
- uploading custom support info, shown to Guest users in Help page #2054
- feature: Dashboard showing all data (favorites, sensors, custom) #1958
- entity for low-temperature boilers pump start temp (pumpOnTemp) #2088 #2088
- internal ESP32 temperature sensor on the S3 #2077
- MQTT status topic (used in connect and last will) set to Retain #2086
- Czech language 2096
- Developer Mode and send EMS Read Commands from WebUI #2116
- Scheduler functions #2115
- Set device custom name from telegram 0x01 #2073
Fixed
- remote thermostat emulation for RC200 on Rego2000/3000 thermostats #1691
- log shows data for F7/F9 requests
- Detection of LittleFS for factory setting wasn't working
- Check for bad GPIOs with Ethernet before the ethernet is initialized
- Show values with factor 50 on webUI #2064
- Rendering of values between -1 and 0
- Value for 32bit times not-set #2109
Changed
- use flag for BC400 compatible thermostats, manage different mode settings
- use factory partition for 16M flash
- store digital out states to nvs
- Refresh UI - moving settings to one location #1665
- rename DeviceValueTypes, add UINT32 for custom entities
- dynamic register dhw circuits for thermostat
- removed OTA feature #1738
- added shower min duration #1801
- Include TXT file along with the generated CSV for Device Data export/download
- thermostat/remotetemp as command #1835
- temperaturesensor id notation with underscore #1794
- Change key-names in JSON to be compliant and consistent #1860
- Updates to webUI #1920
- Correct firmware naming #1933 #1933
- Don't start Serial console if not connected to a Serial port. Will initiate manually after a CTRL-C/CTRL-S
- WebLog UI matches color schema of the terminal console correctly
- Updated Web libraries, ArduinoJson
- Help page doesn't show detailed tech info if the user is not 'admin' role #2054
- removed system command
allvalues
and moved to an action calledexport
- Show ems-esp internal devices in device list of system/info
- Scheduler and mqtt run async on systems with psram
- Show IPv6 address type (local/global/ula) in log